1
DMR Repeater
SBR8040/SCR8040/SER8040
Страница 1: ...Installation and Operation Guide 1 Installation and Operation Guide DMR Repeater SBR8040 SCR8040 SER8040 ...
Страница 2: ...44 0 1223 879000 Sepura plc 2014 SPR DOC 03800 1 Original Instructions ENGLISH All rights reserved This document is intended for the use of Sepura plc s customers and or other parties only for the purposes of the agreement or arrangement under which this document is submitted and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Sepura plc ...
Страница 3: ...earing aids and pacemakers can be affected by RF energy Always consult your service provider or the manufacturer of the medical device before using RF wireless devices Accessories Sepura products have been tested to meet strict guidelines for personal safety and operational conditions Only accessories approved by Sepura are recommended for use with this product Always read the instructions supplie...
Страница 4: ... interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptib...
Страница 5: ...nsmitter The antenna should be installed and operated with minimum distance 1 0m from human body Regulatory Sepura declares that this product is complaint with the essential requirements and other relevant provisions of the European R TTE directive 1999 5 EC relating to radio and telecommunications terminal equipment and the mutual recognition of their conformity This product is also compliant wit...
Страница 6: ...120V 2 5A 50 60 Hz 200 240V 1 5A 50 60 Hz Power Supply DC 10 8 15 6V 15A DC Fuse 13 6V15A AC Fuse 2 5A 250V AC 5x20mm Fuse Type HRC ceramic Time lag T Power Rating 240W Transmitter Power Output 40W Working temperature range 30 to 60 o C 22 to 140 o F For more technical information about this product refer to the product technical datasheet available from our website ...
Страница 7: ...DMR Repeater SBR8000 SCR8000 SER8000 6 Front Panel Rear Panel ...
Страница 8: ...peater has a series of LEDs on the front panel that indicate various operational states LED Description TX A Indicates slot 1 is transmitting RX A Indicates slot 1 is receiving TX B Indicates slot 2 is transmitting RX B Indicates slot 2 is receiving Repeater mode When illuminated the repeater is active When the repeater is inactive the LED is off Analogue mode For analogue or mixed signals the LED...
Страница 9: ...ied notify your Service Provider within 10 days of receipt of the equipment Accessory information Sepura supply a range of accessories for this product Contact your Service Provider or visit our website for a full list of accessories Accessory Part No Wall mount bracket 300 01071 AC Power cable UK 300 01139 AC Power cable EU 300 01141 AC Power cable US 300 01138 AC Power cable AUS 300 01140 Repeat...
Страница 10: ...revent a trip hazard and connections becoming loose The repeater has a battery backup facility that maintains service in the event of an AC power supply failure It is recommended that both AC and DC power supplies are connected to the repeater to prevent loss of service If the AC power supply fails the repeater will shut down and reboot using the DC power supply Time taken to reboot using the DC s...
Страница 11: ...he wall slide the repeater into the bracket Secure the repeater to the wall bracket using the four M5 x 12 screws as shown Attaching the desk mount feet If the repeater is installed onto a desk or bench the four screw type desk mount feet supplied with the product should be attached Using a soft cloth or rubber mat to protect the external surfaces place the repeater with the underside facing upwar...
Страница 12: ...t the black wire to the negative terminal on the DC power source If the power cable needs to be shortened it must be shortened from the DC power source connection end A fuse must be fitted to the positive line red wire when the cable has been shortened A new fuse holder must be fitted not supplied because the existing fuse holder cannot be reused The fuse must be positioned close to the DC power s...
Страница 13: ...al is digital the Digital mode indicator flashes when transmitting The frequency and DCS CTCSS for analogue signals is configured using the DMR Manager software Alarm mode The Alarm indicator on the front panel illuminates when certain operational states warrant When the repeater is in start up mode the LED remains illuminated for the duration of the start up routine approx 60 seconds LED state Al...
Страница 14: ... soft cloth Check cable connections regularly to ensure that they are secure Duplexer specifications An optional duplexer can be used with the repeater The duplexer allows the repeater s receiver and transmitter to operate on a single antenna at the same time When operating within neighbourhoods where other RF devices are installed including broadcast antennas and microwave link transmitters the d...
Страница 15: ...Sepura plc Radio House St Andrew s Road Cambridge CB4 1GR UK Tel 44 0 1223 876000 Fax 44 0 1223 879000 Sepura com ...