3 Command Line Reference
sbo
gbo
setBINEXOutput
getBINEXOutput
Stream
Stream
Cd
Messages
Interval
+ Stream1
...
Stream16
all
none
COM1
COM2
COM3
COM4
USB1
USB2
IP10 ... IP17
NTR1
NTR2
NTR3
IPS1
IPS2
IPS3
IPS4
IPS5
IPR1
IPR2
IPR3
LOG1 ... LOG8
none
+ Rec00
+ Rec0101
+ Rec0102
+ Rec0103
+ Rec0105
+ Rec0106
+ Rec0107
+ Rec0114
+ Rec0141
...
Rec0147
+ Rec05Geod
+ Rec7D00
+ Rec7E01
+ Rec7F05
+ Rec01Nav
+ Rec01Raw
off
OnChange
msec100
msec200
msec500
sec1
sec2
sec5
sec10
sec15
sec30
sec60
min2
min5
min10
min15
min30
min60
RxControl: Communication > Output Settings > BINEX Output > BINEX Output Intervals
Use this command to output a set of BINEX records on a given connection at a regular interval.
A
Stream
is defined as a list of records that should be output with the same interval on one
connection descriptor (
Cd
- see 1.1.5 ). In other words, one
Stream
is associated with one
Cd
and one
Interval
, and contains a list of BINEX records defined by the
Messages
argument.
Refer to appendix B for a short description of the available BINEX records.
Rec01Nav
is
an alias for "
Rec0101
+
Rec0102
+
Rec0103
+
Rec0114
+
Rec0105
+
Rec0106
+
Rec0107
", and
Rec01Raw
is an alias for "
Rec0141
+
Rec0142
+...+
Rec0147
".
The
Interval
argument defines the rate at which the BINEX records specified in the
Messages
argument are output. If set to
off
, the BINEX records are disabled. If set to
OnChange
, the
BINEX records are output at their OnChange rate defined in appendix B. If another interval
is specified (e.g.
sec1
corresponding to an interval of 1 second), the BINEX records are deci-
mated from their OnChange rate to the specified interval. Many records can only be output
at their OnChange rate. For these records, the receiver ignores the value of the
Interval
ar-
gument and always assumes
OnChange
. See the "Flex Rate" column in appendix B to know
if a record can be output at a flexible rate.
Please make sure that the connection specified by
Cd
is configured to allow BINEX output
(this is the default for all connections). See the
command.
Example
To output all the decoded ephemeris records at their OnChange rate together with the GNSS
observables at 1 Hz on COM1, use the following command:
COM1>
sbo, Stream1, COM1, Re Rec7F05, sec1 <CR>
$R: sbo, Stream1, COM1, Re Rec7F05, sec1
BINEXOutput, Stream1, COM1,
Rec7F05, sec1
COM1>
225
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...