5.5. HOW TO USE THE MON
I
TOR
I
NG FEATURE TO CONF
I
GURE THE RECE
I
VER TO POWER DOWN ON
LOW VOLTAGE
5.5 How to use the Monitoring feature to
configure the receiver to power down on
low voltage
The monitoring feature allows the receiver to turn itself o
ff
when the external voltage supply
is below a certain threshold. Note that the monitoring feature only considers the external
voltage supplied to the 3-pin PWR connector and will not consider the voltage when the
receiver is powered using Power over Ethernet or through the internal battery (in case of the
PolaRx5e).
5.5.1 Configuring the monitoring feature
Step 1: Define a voltage threshold and standby time
On the menu bar, select âĂ
Ÿ
StationâĂ
Ź
and then âĂ
Ÿ
Power ModeâĂ
Ź
. Next, click on the
âĂ
Ÿ
MonitoringâĂ
Ź
-tab. Here you can con
fi
gure the voltage threshold and de
fi
ne how long
the receiver should remain in standby before attempting to wake up again as shown in
Figure 5-14.
I
f the voltage level is still below the threshold value when the receiver tries to
wake up, it will remain in standby and will periodically (as de
fi
ned by the standby duration)
check the voltage level until the voltage is at a su
ffi
ciently high level for the receiver to wake
up.
Figure 5-14:
De
fi
ning a voltage threshold and standby time.
I
n this example, the
receiver is con
fi
gured to go into Standby mode when the voltage level drops below
10.5V and to check the voltage after 20 minutes.
57
Содержание PolaRx5
Страница 1: ...PolaRx5 PolaRx5e User Manual ...
Страница 88: ...E LED behaviour 88 ...
Страница 92: ...92 ...