________________________________________________________________________________ 2 AsteRx2eH_PRO
AsteRx2 Product Family Hardware Manual v2.10.1
21
2.2.8
PWR
If you are using a different power adaptor than the one provided by Septentrio, make sure that it can
sustain a current of 1.5A.
2.3
Log Button
The log button toggles internal logging on and off. See the “
HowTo…
” section of the Firmware User
Manual for details.
2.4
Power Button
The power button retains its state through a power outage. If the receiver is on when the power is cut
off, it will automatically restart when the power comes back. If it is off, it will remain off after the
power comes back.
2.5
Status LEDs
The behaviour of the LOGLED, PVTLED, GPLED and TRACKLED is described in Appendix B.
2.6
Cables
Cable Name: CBLe_COM_1,8
Part #: 200416
COM1/COM2 to PC (DSUB9-female). To be connected to either the COM1 or COM2 connector.
Note that RTS/CTS lines are only available when connected to COM2.
Cable Name: CBLe_COM_DUO_7
Part #: 201204
Dual COM3 and COM4 to PC (DSUB9-female). To be connected to the COM3-4/USB connector.
Note that RTS/CTS is not supported on these ports.
Pin #
Description
1
Power: 9 to 30V DC
2
ON/OFF. When this pin is tied to pin#1, the receiver is always on, regardless
of the state of the on/off button.
3
GND