11
Connection pipe (horizontal) max 500 mm, install with 2° inclination backwards from the toilet.
Min 100 mm between the toilet and the wall.
Max 4,5 meters in total length from the 90° bend.
Max 500 mm between the 45° bends.
Max 500 mm above the roof.
Ventilation valve is placed on an outer wall. If placed directly behind the toilet,
underneath the ventilation pipe, min 110 mm Ø, if placed elsewhere min 160 mm Ø.
Connection pipe (horizontal) max 500 mm, install with 2° inclination backwards from the toilet.
Min 100 mm between the toilet and the wall.
Max 4,5 meters in total length from the 90° bend.
Max 500 mm above the roof.
Ventilation valve is placed on an outer wall. If placed directly behind the toilet,
underneath the ventilation pipe, min 110 mm Ø, if placed elsewhere min 160 mm Ø.
Use the supplied short connection pipe (100 mm) between the toilet and the 90° bend.
Max 5 meters in total length from the 90° bend.
Max 500 mm above the roof.
Attach the supplied hose on the drain tap on the 90° bend to divert condensation.
Ventilation valve is placed on an outer wall, min 160 mm Ø.
A
B
C
A
B
C
D
A
B
C
D
A
B
C
A
B
C
D
A
B
C
D
NOTE! Only Ø110 mm vent.pipes and 1pcs 90 ° bend may be used in the installation.
NOTE! Only Ø110 mm vent.pipes and 1pcs 90 ° bend may be used in the installation.