Senville MS9A-09HRDN1-BS0W Скачать руководство пользователя страница 8

13

TROUBLESHOOTING TIPS

Troubleshooting Tips

Stop the air conditioner immediately if one of the following faults occur. Disconnect the
power and contact the nearest customer service center.

Fuse blows frequently or circuit breaker trips frequently.

Other objects or water penetrate the air conditioner.

The remote controller won't work or works abnormally.

Trouble

Malfunctions

Unit does not

start

Unit not cooling

or heating

(Cooling/ heating

models only)

room very well

while air flowing

out from the air

cond tioner

i

Cause

Power cut

Unit may have become unplugged.

Fuse may have blown.

Battery in Remote controller may
have been exhausted.

The time you have set with timer

is incorrect.

Wait for power to be restored.

Check that plug is securely in wall

receptacle.

Replace the fuse.

Replace the battery.

Wait or cancel timer setting.

Set temperature correctly. For

detailed method please refer to

"

"

Using remote control section.

Clean the air filter.

Close the doors or windows.

Clear obstructions away first, then

restart the unit.

Wait.

Inappropriate temperature

setting.

Air filter is blocked.

Doors or Windows are open.

Air inlet or outlet of indoor or

outdoor unit has been blocked.

Compressor 3 minutes

protection has been activated.

If the trouble has not been corrected, please contact a local dealer or the nearest customer

service center. Be sure to inform them of the detailed malfunctions and unit model.

Notes: Do not attempt to repair the unit yourself.

Always consult an authorised service provider.

What should be done?

7. Dripping water may generate on the surface of the indoor unit when cooling in a high

relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed.

8. Heating mode (For cooling and heating models only)

The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner
increases due to larger difference between indoor and outdoor temperature. If a
comfortable temperature can't be achieved by the air conditioner, we suggest you use a
supplementary heating device.

9. Auto-restart function

Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator
on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the

remote controller. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function.
For some models, the machine is special designed with Auto-restart function for the open
angle of the horizontal louver.Power failure during operation or pressing the ON/OFF button
on the remote controller will stop the unit completely.When the power restores or pressing
the ON/OFF button on the remote controller again,the unit restarts automatically with all the
previous settings including the open angle of the horizontal louver by the memory function.
So we strongly suggest that the open angle of the horizontal louver should not be set too
small,in case the condensed water forms and drops from the horizontal louver. Press the

AUTO/COOL button under the front panel and the open angle of the horizontal louver will be

restored to the standard angle when the condensed water forms on the horizontal louver.

10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.

Disconnect the unit with power and then re-connect the unit with power again. Push the
ON/OFF button on the remote controller to restart operation.

11.

The protection of outdoor low temperature(on some models)

The protection of outdoor low temperature can be activated only in the HEATING mode.
The unit will stop operating and  display "P3"  on the LCD window of the indoor unit when the
outdoor temperature is or lower than 5 F(-15 C) for one hour, but the indoor unit in this situation
can still receive the signal from the remote controller.The unit will restart automatically with all the
previous settings preserved by the memory function when the outdoor temperature is or higher
than 11 F(-12 C) for 10 minutes and the compressor stop operating for more than one hour, or
when the outdoor temperature is or higher than 41 F(5 C) for 10 minutes.

O

O

O

O

O

O

OPERATION TIPS

If the following code appears on the LED window, disconnect the power and contact

the service people: E0,E1,E2,E3,E4,E5,E6,E7,E8 or P0,P1,P2,P3,P4, P6.

Operaton indicator or other indicators flash rapidly and this flash can not be
stopped by disconnecting the power and then connecting it in again.

12

Содержание MS9A-09HRDN1-BS0W

Страница 1: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details MS9A 09HRDN1 BS0W MOC 09HFN1 BS0W MS9A 12HRDN1 BS0W MO...

Страница 2: ...se of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at least f...

Страница 3: ...t use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc Do not disassemble or modify unit WARNING Use the correctly rated breaker or fuse There is risk of fire or...

Страница 4: ...mer def This indicator illuminates when the air conditioner is in AUTO operation This indicator illuminates when TIMER is set ON OFF For cooling heating model only This indicator illuminates when the...

Страница 5: ...er initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Manul operation can be used temporarily in case the remote controller is disable or mainte...

Страница 6: ...tioner in AUTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on what temperature you have selected and the room temperature The air cond...

Страница 7: ...f smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating models only mode When indoor temperature reache...

Страница 8: ...ailure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operat...