5.2 Emissivity

10

6. Maintenance

Cleaning the lens: Blow off loose particles using clean

compressed air. Gently brush remaining  debris  away 

with a camel's hair

 

brush.  Carefully wipe  the  surface 

with a moist cotton swab. The swab may be moistened 

with water. 

NOTE: 

DO NOT use solvents to clean the  lens.

Cleaning the housing: 

Use soap and water on a damp sponge or soft cloth.

Non-contact  temperature  sensors  measure  IR  energy  emitted 
by  the  target,  have  fast  response,  and  are  commonly  use  to 
measure moving and intermittent targets, targets in a vacuum, 
and  targets  that  inaccessible  due  to  hostile  environments, 
geometry  limitations,  or  safety  hazard.  The  cost  is  relatively 
high, although in some cases is comparable to contact devices.

Emissivity is the ability of an object to emit or absorb 
energy.  Perfect  emitters have  an  emi ssivi ty   of  1 ,
emitting 100% of incident energy. An object with  an 
emissivity of 0.8 will absorb 80% and reflect 20%  of 

ra

the incident energy. Emissivi y  is  def ined  as t he   tio

t

of  the  energy  radiated   by   an   object   at    given
temperature to the  energy emitted  by a  perfect 
radiator at  the same temperature.  All values  of  
emissivity  fall  between 0.0 and 1.0.

Содержание ST-677

Страница 1: ...Infrared Thermometer TE E R M H O D M S R I E N H F T R A D R E ST 677 ST 677 HDSInfraredThermometer Instruction Manual...

Страница 2: ......

Страница 3: ...HDS Infrared Thermometer Instruction Manual Version 01 07 MAY...

Страница 4: ...ons 4 Operation Instructions Unit Diagram Function 5 Techniques of Infrared Thermometer 6 Maintenance 1 1 Features 2 1 Cautions 4 1 Quick Start 4 2 4 3 Operation 4 4 C F Laser Switch and Battery Chang...

Страница 5: ...d temperature and high DS ratio These allow user to monitor the target temperature for a long distance far away from the potential risk High DS ratio Adjustable emissivity from 0 1 to 1 00 in 0 01 ste...

Страница 6: ...ed accuracy Dangerous refer to this manual before using the meter CE Certification D o n o t p o i n t l a s e r d i r e c t l y a t e y e U s e c a u t i o n a r o u n d r e f l e c t i v e s u r f a...

Страница 7: ...ime 500 ms Emissivity Adjustable 0 1 1 0 Distance Spot Ratio 50 1 Supply Voltage 9V ati a l r m c l pp Auto Power Off Aut aft a rox 6s o e y Operating Temp 0 50 32 122 10 90 RH C F Switchable YES Back...

Страница 8: ...point the unit at the target pull the trigger and hold Be sure to consider the target area inside the angle of vision of this instrument The single spot of laser is used for aiming only 4 2 Unit diagr...

Страница 9: ...3 14 15 SCAN HOLD AUTO C F Indication Main Temperature Display Max Min Avg Set Record Value Lock Key Mode Key Up Button Laser Buzzer On Off Low Battery Data Log T Emissivity High Low Alarm Memory Key...

Страница 10: ...play the temperature during measurement The maximum temperature within one shot measuring The minimum temperature within one shot measuring The average temperature within one shot measuring The highes...

Страница 11: ...functions can be activated always in any step of operations mode in flow chart d In SCAN mode the LCD displays both the current tempera ture in Celsius or Fahrenheit The unit will HOLD the last readin...

Страница 12: ...place the battery when the battery voltage drops below the voltage for reliable operation and at the same time the low battery symbol will appear To change the 9V battery pull open the unit s handle u...

Страница 13: ...t operates and is determined by the optics of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the i m e closer you should be to it When the...

Страница 14: ...measure moving and intermittent targets targets in a vacuum and targets that inaccessible due to hostile environments geometry limitations or safety hazard The cost is relatively high although in som...

Страница 15: ...rolled polished w lines 21 70 0 04 Iron galvanized bright 0 13 Iron plate completely 20 68 0 69 Rolled sheet steel 21 71 0 66 Oxidized iron 100 212 0 74 Wrought iron 21 70 0 94 Molten iron 1299 1399 3...

Страница 16: ......

Страница 17: ......

Страница 18: ...ST 677 Version 01 07 MAY 3F No 122 Sec 1 Sanmin Road Ban Ciao Taipei 220 Taiwan R O C TEL 886 2 2956 8198 FAX 886 2 2956 7662 http www sentrytek com tw PA05 0000677 01...

Отзывы: