Sentry Equipment Corp

Installation

Dangerous gas! Direct the vent line to a charcoal canister, flare, or other subatmospheric region for collection and treatment 

of sample vapors. The gases emitted from the vent line may be hazardous and toxic upon exposure.

Mounting

The Sentry Cobra M sampler is equipped with two (2) 2” NPS Pipe Mounting U-Bolts for mounting to a standard 2” NPS 

Instrument Pipe Stand. Refer to the accompanying drawing for mounting details.

Piping

Refer to the accompanying drawing for connection sizes, types and locations.

 

Â

NOTE

Figures in this manual may differ from actual purchased equipment. Please refer to your job drawings for specific connection 

information.

PI

1

2

SAMPLE INLET

1

SAMPLE RETURN

V-1

CV-1

SAMPLE

BOTTLE

3

VENT

15" 381

8" 203

VARIES BY

BOTTLE SIZE

COBRA FLOW THRU 

SAMPLE VALVE

PRESSURE GAUGE

COBRA NEEDLE

ASSEMBLY

BOTTLE SHROUD

4" 102

2 13/16" 71

SAMPLE INLET

SAMPLE RETURN

VENT

FLOW DIAGRAM

G

F

E

C

D

B

A

G

F

E

C

D

B

A

H

1

2

3

4

5

6

7

FILENAME

H

SHEET 1 OF 1

DWG. NO.

DATE

DRAWN

APPD

CKD

REVISION

8

0

Cobra M Drawing and PID

TRO

08/23/22

Cobra M Drawing and PID

DATE

DATE

Cobra M 

Marketing Drawing

DO NOT SCALE DWG.

REMOVE ALL BURRS AND SHARP

EDGES UNLESS OTHERWISE NOTED

THIS DOCUMENT IS CONFIDENTIAL,

AND CONTAINS INFORMATION

WHICH IS PROPRIETARY TO SEC.

IT IS PROVIDED IN CONFIDENCE

AND UPON THE CONDITION THAT

NEITHER IT NOR THE INFORMATION

CONTAINED IN IT WILL BE COPIED,

DISCLOSED, OR USED IN WHOLE 

OR IN PART WITHOUT THE PRIOR

WRITTEN CONSENT OF SEC.

NOTE:

ALL DIMENSIONS IN INCHES

UNLESS OTHERWISE SPECIFIED

TOLERANCES FOR ALL DIMENSIONS

UNLESS OTHERWISE SPECIFIED

MACH. PARTS

STRUCT.

1/X

.X

.XX

.XXX

ANG.

 1/8

 0.1

 0.01

 0.005

 1/2

 1/2

 0.3

 0.06

 0.030

 1

THIRD ANGLE

PROJECTION

X

7

2

8

5

6

3

4

1

www.sentry-equip.com

Operation

1. 

Verify sample valve is closed 

2. 

Verify all upstream and downstream valves are open to allow representative sample to be taken

3. 

Verify vent line is open to allow for safe venting of bottle

4. 

Insert bottle carefully into shroud and allow Cobra needle to puncture septum

5. 

Close bottle strap

6. 

Turn sample valve counter-clockwise to open and verify liquid is flowing into bottle 

Do not overfill bottle 

Содержание Cobra M

Страница 1: ...Original Instructions Installation Operation Maintenance Manual Sentry Cobra M Sampler Low Emission Samplers S MS IOM 00546 0 09 22...

Страница 2: ...nt may be photocopied or reproduced without the prior written consent of Sentry Equipment Corp Limit of Liability Sentry Equipment Corp its employees agents and the authors and contributors to this do...

Страница 3: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Страница 4: ...r to installing removing or maintaining this equipment ensure that the equipment is isolated from all connecting piping the equipment is depressurized the contents have been drained and the equipment...

Страница 5: ...sures that no pressure is lost while the sample is being taken The standard units come with our special coaxial needle system the risk of bent or broken needles is reduced dramatically The Cobra sampl...

Страница 6: ...H SHEET 1 OF 1 DWG NO DATE DRAWN APPD CKD REVISION 8 0 Cobra M Drawing and PID TRO 08 23 22 Cobra M Drawing and PID DATE DATE Cobra M Marketing Drawing DO NOT SCALE DWG REMOVE ALL BURRS AND SHARP EDGE...

Страница 7: ...e see the Parts Accessories list in this manual Sample Cooler For installation and operating instructions for the sample cooler please see the Installation Operation Maintenance manual for Sentry samp...

Страница 8: ...sample flow Plugged line Blow down line and exercise flow control valve Inspect and or replace needle assembly Leaking valve stems Loose or worn packing Tighten packing nut or replace packing Leaking...

Страница 9: ...ely monitor and measure processes for improved production efficiency output and safety Standing behind our commitments we are determined to tackle any application anywhere We know that running an effi...

Страница 10: ...10 Sentry Equipment Corp This page is intentionally left blank...

Страница 11: ...Sentry Cobra M Sampler 11 This page is intentionally left blank...

Страница 12: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Отзывы:

Похожие инструкции для Cobra M