System Wiring Diagram 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

NC 1 

NO 1 

NC 2 

NO 2 

Red 

=

DC Input:         +12V ~ +24V 

Black 

=

AC Input: ~9V ~ 18V 

White 

=

Normally Open: N/O 

Electric Door Strike Lock

 

Pink 

=

Common - Relay 

Aqua 

=

Normally Close N/C 

Magnetic Lock

 

Brown =

Door Status Detection 
(See

 *

 on page 5 for DSD) 

Orange =

Unlocking 

Button 

Yellow =

Unlocking 

Button 

Green =

GND 

Blue =

NO 

Purple =

COM 

Gray =

NC 

Shielded Ground 

Note:

The first 4 wires (bolded) are the most important.

Power Supply

Door magnet 

Button 1 

Button 2 

GND 

Electric 

Strike Lock

Power 

Supply 

Electric 

Magnetic Lock 

Power 

Supply 

OR

Note:

  White NO 1: For Electric Strike Lock 

Aqua NC 1: For Electric Magnetic Lock 

* Please make sure you are using one of the two locks. 

Red 

Black 

Brown 

Orange 

Yellow 

Green GND 

Blue NO 2 

Purple COM 2 

Gray NC 2 

White NO 1 (+) 
Pink COM 1 (-) 

Aqua NC 1 (+) 

Door 

Bell

Shielded GND

Содержание ACSK-EM

Страница 1: ...ol Keypad with Built in EM Reader ACSK EM Please read the Operational Manual before attempting to use this product Instruction manual subject to change without prior notice from the manufacturer Locks cards sensor and power adaptor not included ...

Страница 2: ... 1 Removing All User and Codes Changing the Unlock Delay Time Pickproof Alarm Door Bell Restoring Factory Default Specifications Package Contents Other Related Product Options Recommended Lock Systems Features Outdoor water resistant Built in EM Reader Card Code Combined access IP65 Rating 125KHz Frequency 1 97 inch 5 cm Effective distance Up to 1000 password card holders for Zone 1 Digital keypad...

Страница 3: ...screws 3 Using the back template as a guide drill the holes for the screws and system wiring make a bigger hole for the system wiring Note Level the back template 4 Draw out the system wiring through the center hole of the back template 5 Mount the back template using the screws provided 6 Mount the front panel using the torque wrench 7 Connect system wiring see System Wiring Diagram and System Wi...

Страница 4: ...ng Button 1 Yellow Unlocking Button 2 Green GND Blue NO 2 Purple COM 2 Gray NC 2 Shielded Ground Note The first 4 wires bolded are the most important Power Supply Door magnet Button 1 Button 2 GND Electric Strike Lock Power Supply Electric Magnetic Lock Power Supply OR Note White NO 1 For Electric Strike Lock Aqua NC 1 For Electric Magnetic Lock Please make sure you are using one of the two locks ...

Страница 5: ... negative to the power negative Connecting an Unlocking Button to Open the Door from the Inside Connect the Orange to the button NO for Strike lock or NC for Magnetic lock Connect the button negative or common to power negative Connecting to Button 2 Connect the Yellow to the button NO for Strike lock or NC for Magnetic lock Connect the button negative to power Connecting the Door Status Detection...

Страница 6: ...ng Admin Code is To enter Setup Mode press Programming Code twice ex The mode indicator will turn yellow To exit or quit from the Setup Mode press Changing Programming Admin Code In Setup Mode press and The mode indicator will flash yellow Enter new Programming Code twice ex A long beep means Programming Code was changed The length of the admin code must be the same as X Please remember your new p...

Страница 7: ...ator will turn yellow and a long beep will sound To exit or quit from the Setup Mode press Length of Password Setting In Setup Mode press and The mode indicator will flash yellow Press and A BI sound will beep Enter X X 2 3 4 5 6 Note 2 stands for the password code length of 2 digits 00 99 3 stands for the password code length of 3 digits 000 999 The rest may be deduced by analogy and the max is 6...

Страница 8: ... rapid beeps and the mode indicator will turn green means that you have exited from Setup Mode The access control will be locked for 60 seconds if one of the following occurs A wrong code is entered continuously An invalid card is swiped 5 times When a door is opened and then closed the system will automatically detect the door status and lock the door even though it is still in delay period for Z...

Страница 9: ...a storage unit existed Press twice to clean up 2 If green LED indictor light is flashing this means the number data storage unit can add card s and password s To add card and passwords 1 Enter Setup Mode The yellow LED indicator light will flash 2 Input a 3 digit number from 000 to 999 data storage units and the green LED indicator light will also flash 3 Swipe card and a sound BI means the card h...

Страница 10: ... card serial number 8 digits A beep will sound indicating the add is successful Removing All User and Codes and cards if also installed In Setup Mode press and The mode indicator will flash yellow Press twice a long beep means all Users and their Codes were removed except Programming Code Exit Setup Mode Changing the Unlock Delay Time ZONE 1 In Setup Mode press and The mode indicator will flash ye...

Страница 11: ...ilt in buzzer will send a continuous beeping if the photoresistor sensor is directly exposed into the light The buzzer will turn off automatically in 60 seconds The light is no longer detected by entering the admin code To turn on In Setup Mode press and The mode indicator will flash yellow Press and A long beep will sound and the mode indicator will turn yellow to indicate that pickproof alarm wa...

Страница 12: ...d or after 60 seconds Door Bell To turn on In Setup Mode press and The mode indicator will flash yellow Press and A long beep will sound and the mode indicator will turn yellow to indicate that pickproof alarm was turned on Exit Setup Mode To turn off In Setup Mode press and The mode indicator will flash yellow Press and A long beep will sound and the mode indicator will turn yellow to indicate th...

Страница 13: ...ctions in 30 seconds During the access mode setting there is a 5 second window to either input password or swipe card If no action is taken within 5 seconds it will revert back When ZONE 1 relay is activated the door LED indicator light will turn green When ZONE 2 relay is activated the door LED indicator light will turn red If you forget the Programming Admin Code press and hold button then power...

Страница 14: ... 0 87 D inches 7 2 W x 11 6 H x 2 D cm Specifications are subject to change without notice Package Contents One 1 Access Control Panel One 1 Mounting Plate One 1 Short Screw Four 4 Long Screws Four 4 Wall Anchors One 1 Torque Wrench One 1 Instruction Manual For any returns please include all components listed above with original packaging in Resalable Condition Absolutely No Returns will be accept...

Страница 15: ... Connect the buzzer negative to power negative B 1 2 CH Wireless RF Receiver Remote B 2 2 CH Wireless RF Receiver Desktop RF Transmitter Error Not a valid link C Door Bell Station w Color IR Camera 7 Color Monitor Station w Door Buzzer Button Single Button 2 Button OR Door Bell Station w Color IR Camera SS NC DS2 7 Color Monitor Station w Door Buzzer Button SS NC DS2 Power Supply w 16 Power Cord S...

Страница 16: ...082011 V03 www SentryUS com Recommended Lock Systems A Magnetic Lock with LED Available in 600 lbs and 1200 lbs B Electric Door Strikes for Metal Door Jaw Strength 2000 lbs 12V DC C Electric Door Strikes for Wood Door Jaw Strength 2000 lbs 12V DC ...

Отзывы: