MODEL: R1M-A1

 

DATA ADDRESS

 

ADDRESS

 

TYPE 

DATA 

NAME

 

 

GH2 

J3 

A1 

D1 

FORMAT

Coil (0X)

1 – 32 

--- 

--- 

--- 

bit 

DO *

1

33 – 48 

--- 

--- 

--- 

bit 

Cold junction compensation SW 

 

 

 

 

 

 

 

 

(0: Disable, 1: Enable) *

2

Input Status (1X)

1 – 32 

--- 

bit 

DI *

3

33 – 48 

--- 

--- 

bit 

ADC overrange

Input Register

1 – 16 

--- 

--- 

--- 

AI in % (1 – 8 for Type J3)

(3X)

17 – 48 

--- 

--- 

AI per channel in engineering unit

49 – 50 

--- 

--- 

--- 

Cold junction temperature *

2

81 – 96 

--- 

--- 

Channel status

513 

Bit 

System Status

 

 

 

 

 

 

0 to 5 

Reserved for system use

 

 

 

 

 

 

E

2

PROM diagnostics (0: Normal, 1: Error)

 

 

 

 

 

 

ADC error (0: Normal, 1: Error)

 

 

 

 

 

 

8 to 15  Reserved for system use

514 – 521 

B16 

Model No. (“R1M-x”)

522 – 529 

B16 

Serial No.

530 – 537 

B16 

Hardware version No.

538 – 545 

B16 

Firmware version No.

Holding Register

1 – 16 

--- 

--- 

--- 

--- 

(Reserved for AO in %)

(4X)

17 – 48 

--- 

--- 

--- 

--- 

(Reserved for AO in engineering unit)

145 – 160 

--- 

--- 

I/O type No.

161 – 176 

--- 

--- 

--- 

Burnout type (161 – 168 for Type J3) 

 

 

 

 

 

 

 

(0: No burnout, 1: Upscale, 2: Downscale) *

4

I = 16-bit integer, F = 32-bit floating, B16 = 16-byte character
*1. Discrete output only.
*2. Thermocouple input only.
*3. Trigger contact input for Types GH2 and J3. (Only Address 10001 is enabled.)
*4. Same setting for all channels. For potentiometer inputs, always leave certain residual resistance at 0% side in order to

avoid wrong burnout detection. (0% input or shortcircuit across the terminals 1 – 2 = Wire breakdown at the terminal 3)

 

ADDRESS 

DATA FORMAT 

NAME

Input Status (1X) 

1 – 32 

bit (1 bit) 

Contact Input

Input Register (3X) 

1 – 32 

Unsigned Long (32 bits) 

Totalized Value

Holding Register (4X) 

1 – 32 

Unsigned Long (32 bits) 

Counter Preset Value

■ 

DATA ADDRESS (COUNTER)

Sign

Address n

• 32-bit Floating

Address n+1

Exponent

Mantissa

Address n, High-order

• 32-bit Integer, No sign (R1M-A1)

Address n+1, Low order

High order bytes

High order bytes

Low order bytes

Low order bytes

 INPUT DATA

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание M-system R1M Series

Страница 1: ...ss Count value is not saved when the power supply is lost Node address setting Rotary switch 1 F 15 nodes RUN indicator LED Green light blinks in normal conditions COMMUNICATION Baud rate 38 4 kbps Co...

Страница 2: ...Reinforced insulation 300 V Input to RS 232 C RS 485 Basic insulation 300 V EXTERNAL VIEW RS 485 Connector Power Terminals Node Address Setting Rotary SW Configurator Jack RUN Indicator LED RS 232 C 9...

Страница 3: ...Shielded Twisted pair Cable To Other PC Recorders Jumper FG U V POWER D SUB CONNECTOR 9 8 7 6 5 4 3 2 1 10 12 11 13 15 14 16 17 18 20 19 21 22 23 24 25 27 26 28 29 30 31 32 33 35 34 36 ch 1 ch 2 ch 3...

Страница 4: ...ngle Registers X General purpose register within the slave 07 Read Exception Status 08 Diagnostics 09 Program 484 10 Poll 484 11 Fetch Comm Event Counter Fetch a status word and an event counter 12 Fe...

Страница 5: ...pe J3 0 No burnout 1 Upscale 2 Downscale 4 I 16 bit integer F 32 bit floating B16 16 byte character 1 Discrete output only 2 Thermocouple input only 3 Trigger contact input for Types GH2 and J3 Only A...

Страница 6: ...E A D DATA Decimal DC 20V 20000 5V 5000 1V 10000 0 8V 8000 0 2V 20000 50mV 5000 10mV 10000 Thermocouple Temperature x 10 RTD Temperature x 10 Potentiometer 0 100 2000 0 500 0 1k 0 10k BIT NAME DESCRIP...

Страница 7: ...CRC 270 to 1000 C 0X13 J IC 210 to 1200 C 0X14 T CC 270 to 400 C 0X15 B RH 100 to 1820 C 0X16 R 50 to 1760 C 0X17 S 50 to 1760 C 0X18 C WRe 5 26 0 to 2320 C 0X19 N 270 to 1300 C 0X1A U 200 to 600 C 0...

Страница 8: ...6 1 81 DIN RAIL 35 mm wide FCN TYPE CONNECTOR T1 T2 T3 T4 T5 T6 T7 104 4 09 10 39 105 4 13 14 55 163 6 42 165 6 50 175 6 89 3 5 20 dia MTG HOLES FOR WALL MOUNT FCN TYPE I O CONNECTOR 6 24 40 1 57 40 1...

Страница 9: ...istance between the PC and the R1Ms is long insert an RS 232 C RS 485 Converter for isolation RS 232 C RS 232 C RS 485 Converter model R2K 1 Specifications are subject to change without notice Ruggh l...

Страница 10: ...ed to the unit and TDK Model ZCAT3035 1330 or equivalent for the RS 232C cable are recommended The equipment must be installed such that appropriate clearance and creepage distances are maintained to...

Страница 11: ...ith the attached jumper pin or with a leadwire When the device is not at the end remove the jumper pin Power Circuit Shielded Twisted pair Cable To Other I O Modules Jumper FG U V POWER D SUB CONNECTO...

Страница 12: ...tor is used when the device is at the end of a transmission line 2 Install shielded cables to all sections and ground them at single point 2 FG RS 485 CHECKING 1 Terminal wiring Check that all cables...

Страница 13: ...W TERMINALS FCN TYPE CONNECTOR T1 T2 T3 T4 T5 T6 T7 104 4 09 10 39 105 4 13 14 55 163 6 42 165 6 50 175 6 89 3 5 20 dia MTG HOLES FOR WALL MOUNT FCN TYPE I O CONNECTOR 6 24 40 1 57 40 1 57 Connector P...

Отзывы: