![Sentiotec P-IS1-T Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/sentiotec/p-is1-t/p-is1-t_instructions-for-installation-and-use-manual_1244690033.webp)
WORLD OF WELLNESS
EN
Installation instructions, only for experts
p. 11/22
1. Guide the connection cable for the room sensor through the cable bushing
in the middle of the housing cover. Do not, under any circumstances, guide
the sensor cables through the existing openings at the bottom.
2. The inlet and outlet for the heating system and lighting are fed out at the
bottom of the housing.
3. Connect all cables and lines to the control unit according to the connection
diagram.
4. Reattach the strain reliefs which were loosened under
point 4.3. Preparing
the housing on page 9
.
There is an ex-works wire jumper at the terminal marked “
r
” (excess
temperature). This should only be removed if a temperature sensor with
safety temperature limiter is connected. The sensor included in the de-
livery does not have a safety temperature limiter.
Foil sensor:
the foil sensor is only required for the operation of infrared
foils and infrared heat plates. If a foil sensor is connected to the control
unit, the maximum cabin temperature is limited to 50° C.
At the “
b - b
” terminals, a resistor is fitted ex-works. This may only be
removed if a foil sensor is connected.