Installation instructions, for professionals only
p. 26/70
5. Electrical connection
ATTENTION!
Damage to the unit
●
The sauna control unit may only be used for operating and controlling 3 heat-
ing circuits with a maximum heating capacity of 3.5 kW per heating circuit.
The maximum evaporator output (only Pro D3/Pro D3i) is 3.5 kW. The maxi-
mum additional output (only Pro D2i/Pro D3i) is 3.5 kW.
1
2
4
3
5
6
b
7
8
9
a
c
d
e
f
1
Low-voltage connection area
2
Terminal strips for safety cut-out, remote
start, status output and sensor wires
3
Function selection switch
4
Cable gland for control panel, F2, FTS2
and foil sensors
5
Cable gland for F1 sensor and status output
6
Cable gland for safety cut-out and
remote start
7
Cable gland for evaporator wire and
additional output
8
Cable gland for heater wire
9
Cable gland for power supply cable
a
Cable gland for power booster
b
Cable gland for lights and fan
c
Terminal strip for heater and evaporator wires,
power supply cable and additional device
d
Terminal strip for lights and fan
e
Terminal strip for power booster
f
Connection area for 230 V/400 V
g
Earth rail
h
RJ10 socket for the control panel
g
h
Содержание 1-041-288/PRO-D2
Страница 141: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES...