SafeScout Users Guide                                          Page 13 

If the walk test code is not entered, the SafeScout system will 
automatically transition back to the disarm state after ten (10) minutes. 
 
For maintenance purposes and to ensure your SafeScout system is 
functioning properly it is recommended that a walk test be conducted 
once a month.  
 
 

Motion Detection and Detection Area 

 
The SafeScout system has a sophisticated passive infrared detector to 
detect motion. This detector looks for infrared energy emitted by people 
and animals. This is the same technology that is used in most high tech 
security applications and systems. 
 
The SafeScout system can detect motion in an area as large as 40 feet by 
40 feet. For maximum detection, your SafeScout must be mounted at 
height between 5 feet and 7.5 feet from the floor. At 4 feet, the detection 
area may be reduced to approximately 30 feet by 30 feet, depending on 
environmental conditions. 
 
 
 
 
 
 
 
 

 

 

It is important to note that certain environmental conditions 
could result in false alarms and/or impaired operation of 
your alarm system. 

The most common examples are light 

dimmers, fluorescent lights, TV or computer CRT displays 
and any piece of electrical equipment using a switching 
power supply or "clock" oscillator (computers and other 
digital devices). 

 

 

Dial Out with 8 or 9 

 

 

Some office and hotel telephone systems require you to dial an 8 or 9 
prior to calling an outside line. Since your SafeScout system must send 

Å

 

40 feet 

 

Æ

 

 

 

 

 

 

63 Degrees

 

Monitoring Unit

 

Area of Coverage

 

 

SafeScout Users Guide                                          Page 14 

calls out to communicate and send alerts, you must program the system 
to allow for this. 
 
To program your SafeScout system to dial an 8 or 9 prior to making 
calls, please complete whichever of the following steps is appropriate: 
 

a)

 

Type “23338*” into the SafeScout monitoring unit keypad to 
add an 8 and a two-second pause in front of the number that is 
dialed out. 

b)

 

Type “23339*” into the SafeScout monitoring unit keypad to 
add a 9 and two-second pause in front of the number that is 
dialed out. 

 
To remove the dial out 8 or 9 request, simply type “23330*” into the 
SafeScout monitoring unit keypad.    
 
 

Arming and Disarming Your System

 

 

Your SafeScout system may be armed and disarmed using either of the 
following two methods: 

1.

 

Enter your passcode on the keypad at the top of the SafeScout 
monitoring unit. 

2.

 

Press and hold the Arm or Disarm button on the remote keyfob 
for up to 5 seconds. 

 
 

Keypad Operation

 

 
To use the keypad on top of the SafeScout monitoring unit to arm or 
disarm your system, simply type your passcode and the # key (for 
example: “1,2,3,4,#”).  Your passcode will arm a disarmed system or 
disarm an armed system. 
 
 

Keyfob Operation

 

 

The remote keyfob allows you to arm or disarm your SafeScout system at 
the touch of a button. Most car alarms use the same type of technology. 
 
To operate the Arm or Disarm features on the keyfob, simply press and 
hold the Arm or Disarm button for up to five (5) seconds.  You will hear 
a verbal acknowledgement that the system is arming or is disarmed. 

Содержание SafeScout

Страница 1: ...1000 Elwell Ct Suite 200 Palo Alto CA 94303 www sentinelvision com 650 964 6200 SafeScout Users Guide Version 3 2 By www sentinelvision com 650 964 6200 ...

Страница 2: ...ect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications to the SafeScout unit not expressly appr...

Страница 3: ...sy steps to successfully setting up your SafeScout Setup usually takes approximately 15 minutes to complete Figure A 1 SafeScout Location and Installation Install one of the backup 9 volt alkaline batteries into your SafeScout monitoring unit Open the battery compartment in the back of your monitoring unit and connect the battery leads Place the battery into the battery holder and close the batter...

Страница 4: ... suggest that you place the siren in a different room from the SafeScout system to confuse potential intruders However do not place the siren more than 50 feet away from the SafeScout monitoring unit Open the battery compartment on the back of the siren with a Phillips head screwdriver and connect the 9 volt alkaline battery to the battery terminal located inside the compartment Replace and secure...

Страница 5: ...registered successfully SafeScout Users Guide Page 8 5 Using Your System Position your system using the view guide at the top of the SafeScout monitoring unit to find the desired viewing angle The SafeScout monitoring unit has a 63 degree angle of view which will protect an area up to 40 feet by 40 feet There is also a clear U shaped mounting bracket enclosed if you wish to angle the SafeScout mon...

Страница 6: ...end that you test the battery located in your SafeScout monitoring unit once a month This can be done by unplugging the AC charger cord from the back of the SafeScout monitoring unit while the unit is in the disarmed state Once the cord has been removed use the keypad or your keyfob to arm the unit If the unit will not arm it is recommended that the 9 volt alkaline battery be replaced Once the tes...

Страница 7: ... it is best to find a different location for the SafeScout monitoring unit so your pet will not trip the SafeScout system when it is armed System Test You can test your system and the related communications at any time by simply pushing the test button on the back of your SafeScout monitoring unit The SafeScout system will conduct a test by capturing one image recording sound and sending the test ...

Страница 8: ...ce your SafeScout system must send Å 40 feet Æ 63 Degrees Monitoring Unit Area of Coverage SafeScout Users Guide Page 14 calls out to communicate and send alerts you must program the system to allow for this To program your SafeScout system to dial an 8 or 9 prior to making calls please complete whichever of the following steps is appropriate a Type 23338 into the SafeScout monitoring unit keypad ...

Страница 9: ...he plus side facing up the same side of the keyfob PCB as the three buttons Failure to do so could destroy your keyfob SafeScout Users Guide Page 16 Inside of keyfob using pen cap to remove battery Siren The SafeScout system includes a wireless siren The SafeScout monitoring unit communicates to the siren using standard wireless RF radio frequency technology This means you can install the siren in...

Страница 10: ...ommunication can delay proper notification and available information All alerts are date and time stamped at the time of occurrence Each alert will be available to review at www sentinelvision com on your user page for 30 days Motion Alert Once a motion is detected within the detection zone while the SafeScout Monitoring Unit is armed the SafeScout wireless siren will sound the soft delay This wil...

Страница 11: ...t any time We recommend that you use the panic alert service in conjunction with the professional monitoring service See Professional Monitoring Service section on page 20 SafeScout Users Guide Page 20 The panic alert feature is part of the automated notification service package The professional monitoring feature requires an additional nominal service fee Entry Notification This service notifies ...

Страница 12: ...to file for a city police permit Some permits require an annual fee and in some cities permits are free Annual fees rarely exceed 30 dollars for the entire year If you have the professional monitoring option or if you believe the police will be dispatched to your home we recommend you telephone your city clerks office or local police department do not use 911 to inquire about governing rules regar...

Страница 13: ...lar com MetroPCS mymetroPCS com mymetroPCS com Nextel messaging nextel com N A Sprint messaging sprintpcs com pm sprint com T Mobile tmomail net tmomail net Verizon vtext com vzwpix com SafeScout Users Guide Page 24 Troubleshooting Guide Problem Solution SafeScout monitoring unit will not force connect SafeScout system will not arm or disarm SafeScout system is not working ________________________...

Страница 14: ...place keyfob s battery Panasonic CR2032 3V Lithium Duracell DL2032 or equivalent Images are not clear or are too dark Check to make sure that the privacy door is open Also check to be sure that the imager camera view is not obstructed Test with additional lighting Sound recording is not clear or cannot be heard Emails sent from Sentinel Vision are not in my inbox Make sure the privacy door is open...

Страница 15: ...by the telephone company Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information SafeScout Users Guide Page 27 Product Warranty Information One 1 Year Limited Product Warranty Sentinel Vision Inc warrants to the original purchaser of this product that it will be free from defects in...

Страница 16: ...R TRANSMIT ANY SIGNAL OR DID NOT GIVE ANY VISUAL OR AURAL WARNING OR THAT THE PRODUCT MALFUNCTIONED OR FAILED HOWEVER IF SENTINEL VISION IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THE LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN OF SUCH LIABILITY SENTINEL VISION S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT...

Отзывы: