www.sentera.eu
MIW-MTX-EN-000 - 02 / 12 / 2015
6 - 7
4.
Mount the internal enclosure to the wall according to the mounting dimensions
shown in
Fig. 2
.
Fig. 2 Mounting dimensions - inset mounting
82
89
26
33
50x50
7
5.
Turn on the mains voltage and controller.
6.
Adjust the minimal speed and turn off the controller.
7.
Mount the cover with the nut.
8.
push the knob in place at off position
II.
For surface mounting
1.
Disconnect the mains supply.
2.
Mount the external enclosure to the wall by dowels and screws (not delivered).
Consider the mounting dimensions shown in
Fig. 3
.
Fig. 3 Mounting dimensions - surface mounting
62
62
7
3.
Remove the knob by turning it to the right, beyond the stop end and then pull.
Open the cover and unscrew the loose nut.
4.
Do the wiring according to the wiring diagram (see
Fig. 1
) using the information
from section
“Wiring and connections”
.
5.
Mount the internal enclosure into the external enclosure by means of the
delivered screws and washers.
6.
Turn on the mains voltage and controller.
7.
Adjust the minimal speed and turn off the controller.
8.
Mount the cover with the nut.
9.
push the knob in place at off position.
NOTE
You can drill a hole (5 mm) at the bottom of the external enclosure to take away
condensed water.
MT