background image

ST230F TELEPHONE LINE TESTER 

 

7

 

The LCD will display the line voltage figure automatically if there is DC voltage in the line. In the following graph, it means 

that there is minus 64.6V DC voltage in the line; then the line which is connected by the red clamp is positive port and the 

black clamp is negative port. 

 

Purpose: This function can be used to test whether the ringing up/off voltage of line is normal or not; it can help lineman to 

distinguish the positive port and negative port of the line quickly in order to ensure whether they connect the line correctly 

or not when install the relevant equipment.   

 

6.2.2 Insulation test   

Press 

“Phone/Tester”

  in  the  normal  status  to  judge  there  is  no  voltage  in  the  line,  and  keep  pressing 

“Test”

  about  3 

seconds to test the insulation. The LCD will display the insulation resistance figure automatically like the following graph. If 

the insulation resistance is less than 20MΩ and there is a fluting sound, it means that the insulation resistance figure of the 

line is small; there is bad insulation fault.       

 

 

Please take off the user phone if you want to test the insulation resistance of the line. 

It can be confirmed whether the fault has been canceled or not through the line insulation test after checking the user line.   

 

6.2.3 Open line test 

In the normal status, connect the tester to the line which will be tested and press

 “Pone/Tester”, 

after confirm there is no 

voltage in the line, keep pressing 

“Test”

 for about 3 seconds. It means that the line is break if the LCD only displays MΩ. 

 

6.2.4 Earth insulation 

Like the above operation, connect the black clamp to earth line and the red clamp to the line which will be tested. The LCD 

will display the earth insulation degree.   

 

6.3 Call user & talk 

Disconnect  the  local  side,  connect  the  test  line  to  passive  user’s  line,  press 

“Phone/Tester”

  (its  right

  LED  on

),  press

 

“Talk”

 after judging there is no voltage in the line and then press

 “Test”,

 and you can call user telephone of the line. (

Call

 

LED on indicates the signal has been sent out); that 

Talk 

LED is on indicates user off hook, loose “Test” enable to talk.   

This function can be used to check the line condition of repair.   

 

6.4 Phone test 

The phone quality can be tested by the ST230F.   

Connect the tester line to the user phone through clamps or assistant line and ring the user phone, it means that the user 

phone is normal if it rings normally; the phone quality is good if the quality of the communication voice is good, otherwise, 

there are faults in the phone.   

 

6.5 Check wire pairs   

64.6V 

16.4 MΩ 

Содержание ST230F

Страница 1: ...ST230F TELEPHONE LINE TESTER USER MANUAL Shandong Senter Electronic Co Ltd ...

Страница 2: ...orage and dial function 6 6 1 7 Data lockout override function 6 6 1 8 Mute function 6 6 1 9 P T transfer function 6 6 1 10 High DC voltage indication 6 6 2 Tester test 6 6 2 1 AC V DC V test 6 6 2 2 Insulation test 7 6 2 3 Open line test 7 6 2 4 Earth insulation 7 6 3 Call user talk 7 6 4 Phone test 7 6 5 Check wire pairs 7 6 6 Monitor 8 6 7 High AC voltage alarm 8 6 8 Low voltage self checking 8...

Страница 3: ...lowing the human engineering theory with the appearance style like barbell it can be put on the shoulder the lineman can do other work using hands at the same time besides it can be hung in the tool belt of waist through the pothook it is convenient to realize the talk function cooperating with the high quality earphone when the lineman is climbing or doing other things the max continuous working ...

Страница 4: ...ndicator will be light Data LED indicator If there is living data ADSL service on the line when you do the data identification operation the data indicator will be light 13 H ACV LED indicator If there is high AV voltage on the line the H ACVA indicator will be light 14 LCD Display telephone number and test result 2 3 Test faceplate Phone Tester Press it to enter test status loose it to enter tele...

Страница 5: ...ller telephone number display FSK DTMF auto compatibility DTMF applying to GB T15279 94 Dialing number display Hands free louder speaker function which can free your hands to do other operations Telephone number storage and dial function Data lockout override function Mute function P T transfer function ADSL ISDN identification High voltage indication Checking wire pairs function as the cable trac...

Страница 6: ...is ringing press Hook to end talk 6 1 3 Redial Press REDIAL you can redial last telephone number If it is busy please hang and press redial again 6 1 4 Caller telephone number display This function is only used in the line which has caller telephone number display service The caller telephone number will be displayed when it receives the TSK or DTMF incoming call The number can be refreshed automa...

Страница 7: ...ok in order not to damage the tester 6 1 8 Mute function Loose all keys connect clamps to the telephone line off hook and press MUTE the other side can not hear our voice and press MUTE again it becomes normal 6 1 9 P T transfer function Loose all keys under test status and no ringing signal this tester can do P T transfer operation Pressing more than 3 seconds can realize pulse dialing and tone d...

Страница 8: ...ther the fault has been canceled or not through the line insulation test after checking the user line 6 2 3 Open line test In the normal status connect the tester to the line which will be tested and press Pone Tester after confirm there is no voltage in the line keep pressing Test for about 3 seconds It means that the line is break if the LCD only displays MΩ 6 2 4 Earth insulation Like the above...

Страница 9: ... and the DATA LED light will be bright accompanying the talk Connect clamps to ISDN network DATA LED light will be bright when user uses this service and there will be rustle sound in the receiver if there is no user using this service you will hear code stream sound like da da and occasionally rustle sound Connect clamps to ADSL line DATA LED light will be bright when user uses this service and t...

Страница 10: ...e higher the voltage which is tested is the longer the distance of electromagnetic eradiation is and the longer the test distance is the rain snow and fog can absorb part of electromagnetism therefore the test distance is small if there is other barriers such as trees house wall and so on and they can absorb part of electromagnetism and the distance is small Please loose all the keys to avoid disc...

Страница 11: ...l It can be inserted into distribution frame conveniently to test the line through the terminal box SHANDONG SENTER ELECTRONIC CO LTD NO 98 WANJIE RD NEW HI TECH AREA ZIBO SHANDONG CHINA P C 255086 TEL 86 533 3589257 FAX 86 533 3587522 WWW SENTER COM CN export senter com cn ...

Отзывы: