WATER CONDITIONER SALT 

 

The  water  softener  needs  'brine'  for  its  periodic 
regenerations. This brine solution is made from water, that 
is automatically  dosed  in the  brine cabinet  by the control 
valve, and water conditioner salt.  
 
The user should make sure that the brine cabinet is always 
kept  full  of  water  conditioner  salt.  Therefore  he  should  
periodically  check  the  salt  level  inside  the  brine  cabinet 
and refill it if necessary. To open the salt lid, simply take it 
by  the  handle  and  lift  it.  The  salt  lid  can  be  removed 
completely to facilitate refilling. 
 

 
Ideally the level of water conditioner salt inside the brine 
cabinet  is  kept  between  1/3  and  2/3.  A  lower  level  of 
water  conditioner  salt  can  cause  insufficient  brine 
saturation,  resulting  in  a  loss  of  softening  capacity.  A 
higher  level  of  water  conditioner  salt  can  cause  salt 
bridging  (hard  crust  or  salt  bridges  in  the  brine  cabinet). 
When you suspect salt bridging: 
1.

 

carefully pound on the outside of the brine cabinet to 
break loose the salt bridges; 

2.

 

using  a  broom  (or  like  blunt  tool)  carefully  push  the 
salt to break it apart; 

3.

 

pour warm water over the top of the salt to dissolve 
it. 

 
 

BRINE CABINET 

 
To  retain  the  appearance  of  the  water  softener,  simply 
wipe  it  with  a  damp  cloth  or  clean  it  with  a  mild  soap 
solution;  never  use  abrasive  cleaners,  ammonia  or 
solvents. 
 
 
 
 
 
 
 

RESIN CLEANER 

 
Other  contaminants  (f.e.  iron)  present  in  the  feed  water 
can  cause  the  resin  bed  to  foul  up,  resulting  in  a  loss  of 
softening  capacity. An approved resin cleaner can be used 
periodically to thoroughly clean the resin bed. 
 
 

SANITIZING THE WATER SOFTENER 

 

This water softener is manufactured from premium quality 
material  and  assembled  in  safe  conditions  to  assure  it  is 
clean  and  sanitary.  If  installed  and  serviced  correctly,  this 
water  softener  will  not  infect  or  contaminate  your  water 
supply. 
 
However,  as  in  any  'device'  plumbed-in  in  your  water 
distribution system, a proliferation of bacteria is  possible, 
especially  in  case  of  'stagnant  water'.  As  this  is  a  time-
controlled  water  softener,  it  will  automatically  rinse  the 
resin  bed  periodically,  even  in  case  of  low  or  absence  of 
water usage. 
 
If the power supply to the water softener is disconnected 
for  a  longer  period  of  time,  we  recommend,  when  the 
power  supply  is  re-established,  to  manually  initiate  a 
complete  regeneration  (refer  to  section  'ELECTRONIC 
CONTROL PANEL'). 
 

 

Содержание Eco

Страница 1: ...OM ENG SentenciaEco Rev2010 10 O OW WN NE ER R S S M MA AN NU UA AL L Eco Eco WATER SOFTENER SYSTEM ...

Страница 2: ...ll in the following data INSTALLATION RECORD Serial Number _______________________________________________ Model ________________________________________________________ Water Hardness inlet _______________________________________ Water Hardness outlet _____________________________________ Water Pressure inlet ________________________________________ Date of Installation __________________________...

Страница 3: ... by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water softener make sure to check it for any externally visible damage do not install or use when damaged Use a hand truck to transport the water softener To prevent accident or injury do not hoist the water softener over your shoulder D...

Страница 4: ...outdoor elements such as direct sunlight or atmospheric precipitation do not install the water softener too close to a water heater keep at least 3 m of piping between the outlet of the water softener and the inlet of the water heater water heaters can sometimes transmit heat back down the cold pipe into the control valve always install a check valve at the outlet of the water softener ELECTRICAL ...

Страница 5: ...ater softener untreated water outlet of water softener treated water house application treated water 1 Screw the factory bypass onto the elbow connections of the water softener make sure to install the gasket seals Tighten the nuts firmly by hand 2 Screw the brass connection kit with nuts onto the factory bypass make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the ma...

Страница 6: ...o the drain solenoid of the control valve secure it by means of a clamp 2 Run the drain hose to the drainage system and connect it to the stand pipe assuring sufficient air gap This drain line operates under pressure so it may be installed higher than the water softener 3 Connect a 13 mm hose to the overflow elbow located at the back side of the water softener secure it by means of a clamp 4 Run t...

Страница 7: ...he bypass valve 2 open the outlet valve 3 slowly open the inlet valve 6 After 2 3 minutes open a cold treated water faucet nearby the water softener and let the water run for a few minutes until all air is purged from the installation close the tap 7 Check the water softener and all hydraulic connections for leaks BRINE CABINET 8 Add water conditioner salt to the brine cabinet ELECTRONIC CONTROL P...

Страница 8: ...ginning TIMER FAILURE In the event of a timer failure the display will show the message In such case entering one of the programming levels can possibly solve the problem However if the problem persists professional service is required SERVICE MODE In service mode the display shows the time of day and the remaining number of days REGENERATION MODE In regeneration mode the display shows the actual ...

Страница 9: ... the display will show Press the up button or down button to set the language 2 Press the scroll button again the display will show Press the up button or down button to set the time of day 3 Press the scroll button again the display will show Press the up button or down button to set the hardness of the incoming untreated water Language English Set time 20 51 Set hardn XX f ...

Страница 10: ...o the house application refill swimming pool irrigation WITH FACTORY BYPASS optional SERVICE POSITION inlet valve to water softener is OPEN outlet valve from water softener is OPEN BYPASS POSITION inlet valve to water softener is CLOSED outlet valve from water softener is CLOSED WITH 3 VALVE BYPASS SYSTEM not included SERVICE POSITION bypass valve is CLOSED inlet valve to water softener is OPEN ou...

Страница 11: ...t to break it apart 3 pour warm water over the top of the salt to dissolve it BRINE CABINET To retain the appearance of the water softener simply wipe it with a damp cloth or clean it with a mild soap solution never use abrasive cleaners ammonia or solvents RESIN CLEANER Other contaminants f e iron present in the feed water can cause the resin bed to foul up resulting in a loss of softening capaci...

Страница 12: ... draw brine Improper brine refill time setting Verify that brine refill time corresponds to the proper salt level and amount of resin Missing brine refill flow control Verify that flow control is installed and properly sized Leak from control valve to brine cabinet Clean or replace plunger and solenoid diaphragm of refill solenoid Salt taste in treated water Excessive water in brine tank Refer to ...

Страница 13: ...or brine restrictor Clean injector and or brine restrictor Plugged injector filter Clean injector filter Restricted drain line Verify drain line for kinks or restrictions Restricted brine line Verify brine line for kinks or restrictions Leak in brine line Verify brine line and connections for air leakage No water in brine tank Refer to problem Control valve fails to refill brine tank Backwash sole...

Страница 14: ...93 Salt usage per regeneration kg 3 1 4 1 9 2 5 3 3 4 0 Exchange capacity per kg salt m x f 41 Exchange capacity per kg salt m x d 23 Recommended maximum service flow m hr 1 1 1 5 2 0 2 6 3 2 Rinse water usage per regeneration 3 bars Ltr 3 59 80 92 116 141 2 Indicative numbers performances depending on operating conditions and water quality 3 Maximum salt water usage as brining is proportional min...

Страница 15: ...32 44 58 75 Salt usage per regeneration kg 3 1 4 1 9 2 5 3 3 Exchange capacity per kg salt m x f 41 Exchange capacity per kg salt m x d 23 Recommended maximum service flow m hr 1 1 1 5 2 0 2 6 Rinse water usage per regeneration 3 bars Ltr 3 97 118 149 185 2 Indicative numbers performances depending on operating conditions and water quality 3 Maximum salt water usage as brining is proportional mini...

Страница 16: ...NOTES Page 16 ...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: