Sensus 243-12-1 Скачать руководство пользователя страница 3

Model 243 Regulator
Illustrations

243-12-2

I.R.V. Regulator

- as shown -

243-12-1

Same as I.R.V. Regulator
except no Internal Relief
Valve and Standard Cover
Cap as shown in inset.

PIPE SIZES
2” Flanged ANSI 125 lb FF
1

1

2

” and 2” Screwed

243-8 HP

Remainder of regulator
same as 243-8-1

PIPE SIZES
2” Flanged ANSI 125 lb FF
1

1

4

”, 1 

1

2

” and 2” screwed

243-8-1

Standard Regulator

- as shown -

243-8-2

Same as Standard
Regulator except
Internal Relief Valve as
shown in inset.

PIPE SIZES
2” Flanged ANSI 125 lb FF
1

1

4

”, 1 

1

2

” and 2” screwed

Drilled and Tapped 

1

2

” NPT

on regulators arranged for
External Control Line

STANDARD
DIAPHRAGM
ASSEMBLY

INTERNAL

RELIEF

VALVE

Drilled and Tapped

1

2

” NPT on regulators

arranged for External
Control Line

THROAT BLOCK
WITH O-RING SEAL
(for regulators arranged
for External Line Control)

1

2

3

4

5

8

9

10

11d

11f

13

11k

11b

11a

16

20b

21

24

1e

2a

25

27

26

25

11d

11a

11d

13

28

17

18

10

19

21

11k

11a

11d

5

13

1

2

3

4

5

8

9

10

11b

11a

16

20b

21

24

28

17

11d

11f

13

2

4

5

11e

13

10

11f

11b

11a

11s

1d

15

15

16

Vent

1” NPT

10

3

16

” Dia.

9

3

4

8

19

32

7” or 10”

7” or 10”

9

3

4

” (IRV COVER CAP)

10” (STD COVER CAP)

14” Dia.

10

13

32

Vent
1” NPT

STANDARD
CAP

3

5

8

5

8

Содержание 243-12-1

Страница 1: ... to various positions in relation to the body Make certain 16 are re tightened to hold diaphragm case assembly in new position and to reseal CAUTION The diaphragm case vent must be positioned to protect against flooding drain water ice formation traffic tampering etc The vent must be protected against nest building animals bees insects etc to prevent vent blockage and minimize the chances for fore...

Страница 2: ...icing make certain that regulator installation is entirely free of leaks CAUTION Regulators are pressure control devices with numerous moving parts subject to wear that is dependent upon particular operating conditions To assure continuous satisfactory operation a periodic inspection schedule must be adhered to with the frequency of inspection determined by the severity of service and applicable l...

Страница 3: ...5 lb FF 1 1 4 1 1 2 and 2 screwed Drilled and Tapped 1 2 NPT on regulators arranged for External Control Line STANDARD DIAPHRAGM ASSEMBLY INTERNAL RELIEF VALVE Drilled and Tapped 1 2 NPT on regulators arranged for External Control Line THROAT BLOCK WITH O RING SEAL for regulators arranged for External Line Control 1 2 3 4 5 8 9 10 1 1d 1 1f 13 1 1k 1 1b 1 1a 16 20b 21 24 1e 2a 25 27 26 25 1 1d 1 1...

Страница 4: ...alone This applies with the monitor located either up or downstream SPRING COLOR Red Red Black Blue Blue Black Green Black Green Orange Black Orange Black Cadmium Cadmium Cadmium White t PART NUMBER 143 16 021 03 143 82 021 00 143 16 021 04 143 82 021 01 143 82 021 02 143 16 021 05 143 16 021 11 143 16 021 06 143 16 021 07 143 16 021 08 143 16 021 08 143 16 021 08 143 16 021 13 243 12 3 1 2 to 6 1...

Страница 5: ...0 8 000 11 000 15 000 18 000 21 000 22 000 19 000 15 000 5 400 7 000 8 500 10 500 14 500 18 000 20 000 22 000 19 000 15 000 6 800 8 600 10 500 13 000 20 000 25 000 25 000 25 000 19 000 15 000 O O O O O O O O O O O O O O O O O O O O O O O O O INLET PRESSURE psi ORIFICE SIZE AND VALVE ANGLE 6 w c RED BLACK SPRING 1 w c droop 7 w c BLUE BLACK SPRING 1 w c droop 18 w c GREEN SPRING 3 w c droop 1 psi O...

Страница 6: ...ods which have been i repaired altered or improper ly installed ii subjected to improper use or storage iii used or incorporated with other mate rials or equipment after Buyer or anyone using the Goods has or reasonably should have knowledge of any defect or nonconformance of the Goods or iv manufactured fabricated or assembled by anyone other than Seller c shall not be effective unless Buyer noti...

Отзывы: