The Multifunction card
Senstar 100 Installation guide • • • 2 - 9
Installing the MFC
Installation requirements
•
a vacant PCI slot for the MFC and a second unoccupied rear panel slot for the
interface card (no motherboard slot required for the interface card)
•
Senstar 100 software package
The Multifunction card includes static sensitive components.
Follow proper ESD procedures when handling the card.
Figure 2-3 Interface card
SENSTAR-STELLAR CORP.
J2BA0500-001
REV ____
J4
J1
J3
J2
relay 1 N.C.
relay 1 common
relay 1 N.O.
relay 2 N.C.
relay 2 common
relay 2 N.O.
relay 3 N.C.
relay 3 common
relay 3 N.O.
relay 4 N.C.
relay 4 common
relay 4 N.O.
J1 serial port 2
(DB-9 male)
J4 relay O/Ps
(removable screw
terminal block)
J3 10-pin header
(serial port 2)
connect to J1 on MFC
J2 14-pin header
(connect to J6 on MFC)
Cau
tion