WALL SWITCH
0 ft
0 m
4
1.2
SIDE VIEW
0 ft
0 m
10
3.0
20
6.1
30
9.1
40
12.2
TOP VIEW
4 ft Mount
40
12.1
40
12.1
20
6.1
0 ft
0 m
20
6.1
COVERAGE
Ã
Ã
30” to 48’ (0.76 - 1.22 m) recommended mounting height
Ã
Ã
Wall to wall (~180 degree) coverage
Ã
Ã
Small motion (e.g., hand movement) detection up to 20 ft (6.10 m), ~625 ft
2
Ã
Ã
Large motion (e.g., walking) detection greater than 36 ft (10.97 m), ~ 2025 ft
2
Ã
Ã
Overlapping acoustic detection of occupants over entire coverage area
Ã
Ã
Advanced signal processing filters out nuisance noises while not effecting
overall sensitivity
Ã
Ã
As an added safety convenience, the acoustic detection is left active for
10 seconds after sensor turns the lights off to allow for voice reactivation
BLK
WHT
LOAD
BLK
N
SWX
WALL SWITCH
SENSOR
H
GRN
BLK
WHT
BLK
N
N
SWX
WALL SWITCH
SENSOR
H
GRN
BLK
WHT
LOAD
BLK
SWX
WALL SWITCH
SENSOR
N
GRN
BLK
WHT
BLK
N
SWX
WALL SWITCH
SENSOR
GRN
Standard Wiring
3-Way Wiring
H
1-Sensor: 3-Way Wiring
3-WAY SWITCH
COMMON
TRAVELERS
TRAVELERS
LOAD
*
NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
*
*
*
*
*
NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
*
NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
BLK
WHT
LOAD
BLK
N
SWX
WALL SWITCH
SENSOR
H
GRN
BLK
WHT
BLK
N
N
SWX
WALL SWITCH
SENSOR
H
GRN
BLK
WHT
LOAD
BLK
SWX
WALL SWITCH
SENSOR
N
GRN
BLK
WHT
BLK
N
SWX
WALL SWITCH
SENSOR
GRN
Standard Wiring
3-Way Wiring
H
1-Sensor: 3-Way Wiring
3-WAY SWITCH
COMMON
TRAVELERS
TRAVELERS
LOAD
*
NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
*
*
*
*
*
NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
*
NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
3-WAY WIRING
TWO SENSORS IN PARALLEL
Ã
Ã
Both sensors must time out for lights to turn off (or both buttons
must be switched)
Ã
Ã
Recommended for Automatic On (Occupancy) applications only
INSTALLATION
STANDARD WIRING
WARNING: TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING
* NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
* NEUTRAL CONNECTION IS OPTIONAL, CAP IF UNUSED
WIRING
Ã
Ã
For supply connections, use 14 AWG (90° C) or larger wires
Ã
Ã
Risk of Electric Shock - more than one disconnect switch may be required
to de-energize the equipment before servicing
Ã
Ã
It is recommended that wiring the unit’s ground connection be done first.
Ã
Ã
Unit works both in installations where Neutral connection is available as
well as installations where only Ground connection is present
Ã
Ã
The unit’s two black wires are interchangeable (e.g., one connects to line
power, one connects to load)
Ã
Ã
After wiring and mounting, install wall plate (not included) before turning
back on power at the circuit breaker