background image

 

SEC P/N: 1460014 

 

Rev / ECO: A / 000209 

Page 

2

 of 

26

 

 
 

 

 

 
 
 
 
 
 
 

 

Commitment 

Our quality and service are uncompromising. We back each of our products with a two-year warranty on all 
materials and workmanship. We offer technical support, user training and on-site service and maintenance 
of equipment to meet the needs of our customers. 

 

Gas Detection Service 

Individually designed maintenance packages are available for specific customer needs. Service begins with 
verification of the system installation that includes an initial system check and calibration. We then offer 
customer  training  programs  (on-site  and  at  factory)  to  insure  that  technical  personnel  fully  understand 
operation and maintenance procedures. When on-the-spot assistance is required, service representatives 
are available to handle any questions or problems immediately. 

 

Warranty 

Sensor Electronics Corporation (SEC) warrants products manufactured by SEC to be free from defects in 
workmanship and materials for a period of two (2) years from date of shipment from the factory. Any parts 
returned  freight  pre-paid  to  the  factory  and  found  defective  within  the  warranty  would  be  repaired  or 
replaced,  at  SEC's option.    SEC  will  return repaired  or replaced  equipment  pre-paid lowest  cost  freight.  
This warranty does not apply to items, which by their nature are subject to deterioration or consumption in 
normal service. Such items may include: 
Fuses and Batteries. 
Warranty  is  voided  by  abuse  including  rough  handling,  mechanical  damage,  alteration  or  repair.  This 
warranty covers the full extent of SEC liability and SEC is not responsible for removal, replacement  costs, 
local  repair  costs,  transportation  costs  or  contingent  expenses  incurred  without  prior  written  approval.  
Sensor Electronics Corporation's obligation under this warranty shall be limited to repair or replacement of 
any  product  that  has  been returned  to  Sensor  Electronics  Corporation  for  warranty  consideration.    This 
warranty is expressly in lieu of any and all other warranties expressed or implied, and all other obligations 
or  liabilities  on  the  part  of  Sensor  Electronics  Corporation  including  but  not  limited  to,  the  fitness  for  a 
particular  purpose.  In  no  event  shall  Sensor  Electronics  Corporation  be  liable  for  direct,  incidental,  or 
consequential loss or damage of any kind connected with the use of its products or failure to function or 
operate properly. 

 

 
 
 

 

 

Содержание SEC 3500 HMI

Страница 1: ...ECO A 000209 Page 1 of 26 SEC 3500 HMI Operator Interface Hardware Manual Sensor Electronics Corporation 12730 Creek View Avenue Savage Minnesota 55378 USA 952 938 9486 Fax 952 938 9617 Email sales s...

Страница 2: ...defective within the warranty would be repaired or replaced at SEC s option SEC will return repaired or replaced equipment pre paid lowest cost freight This warranty does not apply to items which by t...

Страница 3: ...SEC P N 1460014 Rev ECO A 000209 Page 3 of 26 Table of Contents Contents I SPECIFICATIONS 5 II GENERAL DESCRIPTION 6 III OPERATION 7 IV INSTALLATION 8 V DRAWINGS 9 VI TESTING 25 VII MAINTENANCE 26...

Страница 4: ...cheme Update Specifications Add Installation Steps Add Testing Add Maintenance Add UL2017 Information All 2 10 26 2016 Change model to SEC3500 HMI Add all Components Inside Enclosure to Specs Add Reco...

Страница 5: ...ontacts 1 NO 1 NC per Relay Contact Rating 8A 30VDC 8A 250VAC Type AM System System Components SEC 3500 Operator Interface Red Lion HMI SEC 3100 Gas Transmitter Not UL 2017 Approved SEC 3500 XX Relay...

Страница 6: ...a power indicator LED located on the front panel of the 3500 Network devices can be interrogated configured and calibrated using the password protected touchscreen user interface 16 embedded programm...

Страница 7: ...e SEC3500 HMI Operator Interface is an intuitive operator interface For the individual page operations please refer to the following individual instruction manuals on the SEC website 3500 OI Basic Ope...

Страница 8: ...UL 1310 approved Then run the power through the bottom left hole of the SEC 3500 unit Then connect the power supply to the DC to DC converter 3 Run the RS485 Data Highway through the bottom left side...

Страница 9: ...SEC P N 1460014 Rev ECO A 000209 Page 9 of 26 Class 2 Power Supply Earth Ground Bolt NOTE COM ON THE SEC 3100 ISO REFERS TO THE ISO COMMON NOT DC COMMON...

Страница 10: ...Rev ECO A 000209 Page 10 of 26 V DRAWINGS Part Number Description 1421901 Mounting and Dimensional Drawing 350000016X16X10 Internal Component Layout 1460015 separate document Overall Wiring Diagram W...

Страница 11: ...SEC P N 1460014 Rev ECO A 000209 Page 11 of 26...

Страница 12: ...SEC P N 1460014 Rev ECO A 000209 Page 12 of 26...

Страница 13: ...he SEC 3500 and RS485 Data Highway Connection TB1 Earth Ground Connection 1 2 3 4 5 6 7 8 Ground Stud Enclosure Wall Terminal Description 1 2 AMP Circuit Breaker Power for SEC 3500 only 2 DC Common 3...

Страница 14: ...SEC P N 1460014 Rev ECO A 000209 Page 14 of 26 24 VDC POWER SUPPLY 1 2 3 4 5 6 7 8 SEC 3500 Terminal Block WIRING EXAMPLE SEC 3500 TO SEC 3100 TRANSMITTERS AND SEC 3500 8 RELAY CONTROLLER...

Страница 15: ...ANALOG OUTPUT TB 3 SENSOR WIRING TB 1 RELAY WIRING BACK VIEW OF SEC 3100 SEC 3100 WIRING SENSOR ELECTRONICS CORPORATION 12730 CREEK VIEW AVE SAVAGE MINNESOTA 55378 USA T 952 938 9486 F 952 938 9617 s...

Страница 16: ...ult N O 4 Mid Alarm N C 5 Fault Common 5 Mid Alarm Common 6 Fault N C 6 Mid Alarm N O 1 TB1 6 1 TB2 6 1 TB5 4 1 TB6 6 TB 5 Sensor Wiring TB 6 Power Data Wiring 1 DC Common Black 1 Data A 2 24 VDC Red...

Страница 17: ...AMPS 250 VAC OR 8 AMPS 30 VDC COMMUNICATION ISOLATED RS485 MODBUS WEIGHT SEC 3500 8 RELAY CONTROLLER PN 1421999 2 LBS SEC 3500 16 RELAY CONTROLLER PN 1422182 3 LBS POWER SEC 3500 8 RELAY CONTROLLER 4...

Страница 18: ...K3 K4 7 8 9 1 01 11 2 1 2 3 4 5 6 K5 K6 K7 K8 7 8 9 1 01 11 2 1 2 3 4 5 6 K9 K10 K11 K12 7 8 9 1 01 11 2 1 2 3 4 5 6 K13 K14 K15 K16 DATA LED POWER LED K1 K2 K3 K4 K5 K6 K7 K8 K16 K15 K14 K13 K12 K11...

Страница 19: ...SEC P N 1460014 Rev ECO A 000209 Page 19 of 26 SEC 3500 8 RELAY CONTROLLER DIMENSIONS SEC 3500 16 RELAY CONTROLLER DIMENSIONS...

Страница 20: ...junction with the SEC 3100 transmitters and the SEC 3500 HMI Operator Interface or other MODBUS RS 485 data highway systems The SEC 3100 ISO RS 485 Repeater Module is used to extend the distance of th...

Страница 21: ...if the SEC 3100 had an SEC gas detector connected The SEC 3100 transmitter reports the foreign device status bidirectional to the SEC 3500 HMI Operator Interface via the MODBUS RS485 communication ne...

Страница 22: ...ter Open Path Gas Detector Pyrolyzer Temperature Transmitter Fire Detector SEC 3100 AIM SEC 3100 Transmitter back side NOTE Refer to the SEC 3100 Transmitter Instruction Manual for additional wiring c...

Страница 23: ...and High contact closure from the device converts the input signal into a digital signal compatible with the SEC 3100 transmitter The SEC 3100 LIM is factory programmed with the following customer su...

Страница 24: ...ransmitter Instruction Manual for additional wiring connections SEC 3100 Explosion Proof Transmitter Switch Device Pressure Switch Open Path Gas Detector Air Flow Switch Temperature Switch Fire Detect...

Страница 25: ...ugh these alarms the 3500 screen should show the sensor going into alarm and respond accordingly turn fan on siren lights etc depending on the user s system settings and what the response to those ala...

Страница 26: ...ECO A 000209 Page 26 of 26 VII MAINTENANCE Maintenance will need to be done by SEC personal The maintenance needed is minimal If issues arise and maintenance is needed please contact Sensor Electroni...