FT 50 RLA Distance sensor - GB - 068-13799 - 27.07.2010-01
19
Mounting and
operating instructions
7.2
Possible Settings and Operating Modes
· Set the switching point or switching window
· Scale the analogue output
· Set the operating mode (Speed Mode / Averaging Mode )
· Set the switching type (N.O. / N.C)
· Reset the sensor to the factory state
· Laser off and measured value hold (via electrical connection)
· Lock buttons
S
and
T
(via electrical connection)
7.3
Factory State
· Switching output:
Switching output is active when the object is in the operating range and reliably detected. Switching type = N.O.
· Analogue output (4 ... 20 mA):
4 mA = end of operating range, 20 mA = beginning of operating range
· Operating mode = speed mode (shortest response time)
· Operation
= free running (normal mode)
7.4 Make settings
7.4.1
Activating the Set Mode (conf)
Push the buttons
S
and
T
simultaneously for 3 s (or longer) until the LED BA (green) flashes
(LED flashes when time lock open and Set mode activated).
7.4.2
Setting the Sensor
No. LED pattern Action
Factory setting
Description
1a
Q
A
V
N
C
QA
OK
FS
Set switching point for switching output Q
Position the object at the desired switching point. The „OK“ LED must light.
Push
T
until the „Q“ LED lights.
Push
S
once. If the object is detectable and in the operating range, the „ZA“
LED (red) flashes with 1 Hz.
Exit the Set menu (
T
+
S
) or
go to the next setting with
T
.
Switching window
over the whole
operating range,
i.e. switching
output is active
when the object
is in the operating
range and reliab-
ly detected.
1b
Q
A
V
N
C
QA
OK
FS
Set the switching window for switching output Q
Position the object at the desired first switching window limit. The „OK“ LED
must light.
Push
T
until the „Q“ LED lights.
Push
S
once. If the object is detectable and in the operating range, the „ZA“
LED (red) flashes with 1 Hz.
Position the object at the desired second switching window limit. The „OK“
LED must light.
Push
S
once. The distance is saved as the second switching window limit if
the object is detectable and in the operating range. The „ZA“ LED lights for
confirmation for as long as
S
is pushed.
Exit the Set menu (
T
+
S
) or
go to the next setting with
T
.
Information
If the object was not moved after teaching the first switching window limit, a minimum switching window
(1 % of the operating range) is laid around the teach point.