Parameters panel descriptions 

 

Table 6: Parameters panel descriptions 

Panel unit 

Functionality and description 

===== General parameters ===== 

 

Password 

Current valid password to be able to edit the parameters list. The 
password is “stim” 

Folder for result-file storage 

“c:\userdata\test\ 

What priority will this program run with 

Instructs the program priority for the PC operation system 

What format to use for result files 

ASCII text by default. Can be changed to 8 byte binary 

Name of file with language definitions 

Application can be configured with language other than English 

===== Device communication ===== 

IMPORTANT MESSAGE: Always verify 
hardware connections and COM port settings 
before trying to connect to the device 

 

RS422 port # to device 1 

Defining which COM port # to be assigned to gyro module (device) # 

RS422 port # to device 2 

Defining which COM port # to be assigned to gyro module (device) # 

RS422 Bitrate [bit/s] 

Manual RS422 bit rate selection. NOTE that USB cable that comes 
with the USB kit, supports only the default 460800 bits/s option, while 
the PCI card of the PCI kit supports all available bit rates 

RS422 Stopbit 

1 or 2. Default is “1” 

RS422 parity 

N

one, odd or even. Default is “None” 

===== External Hardware ===== 

 

The GPIB Card Number To Use 

Normally "0" (when no GPIB card in user). If card(s) are in use; the 
first card will be assigned to #1, second to #2, etc. Default value is 
“0” 

Type Of Power Supply In Use 

Normally "None" (when not in use). Agilent E3631A, E3633A and 
E3644A supported. Default value is “None” 

Interface To Power 

Normally "None" (when not in use). RS232 (for Agilent E3631A only) 
and 

GPIB supported. Default is “None” 

Port Or Address To Power 

Normally "0", when not in use. Selectable up to 31

. Default is “0” 

Voltage On Output Of Power Supply [V] 

Default value is “5.1”. Can be neglected if not in use. Value should 
be within the supply voltage range of the gyro module. Clicking on 
the arrow of the control unit when editing this parameter allows for 
voltages as high as 6.0V maximum. Manual entry allows even higher 
values, however with a warning. Note: The entered value/ voltage 
applied to the gyro module should never exceed the absolute 
maximum ratings value for the supply voltage of the gyro module 
(maximum 7.0V) 

Current Limit On Output Of Power Supply [A] 

Default value is “1.0”. To limit the current consumption from the 
power source 

 

Содержание STIM202

Страница 1: ...TIONS 9 6 3 1 Common preparations 9 6 3 2 For preparing the PCI kit skip this step if the USB kit is used 9 6 3 3 For preparing the USB kit skip this step if the PCI kit is used 9 6 3 4 Common verific...

Страница 2: ...luation kits are available for either PCI or USB connectivity 1 STIM202 EVK PCI The evaluation kit with PCI connectivity is the recommended solution for thorough characterization The kit is in the fol...

Страница 3: ...HD memory and processor capacity of PC o Various stop criteria for measurement series Manually No of samples or Time elapsed Measurements on 2 gyro modules simultaneously supported requires either on...

Страница 4: ...stallations are required NI serial driver installation PC software installation 6 1 Installation of NI serial driver Install the National Instruments NI serial driver from the CD ROM included in the k...

Страница 5: ...te 6 2 Installation of PC software Install the PC software by running setup exe found on the included memory stick Follow the on screen instructions to complete the installation See Figure 5 through F...

Страница 6: ...USER MANUAL EvaluationTool STIM202 Evaluation Kit DOK333 rev 06 6 22 Dec 2017 Figure 5 PC software installation 1 of 6 Installer initialization Figure 6 PC software installation 2 of 6...

Страница 7: ...USER MANUAL EvaluationTool STIM202 Evaluation Kit DOK333 rev 06 7 22 Dec 2017 Figure 7 PC software installation 3 of 6 Figure 8 PC software installation 4 of 6...

Страница 8: ...USER MANUAL EvaluationTool STIM202 Evaluation Kit DOK333 rev 06 8 22 Dec 2017 Figure 9 PC software installation 5 of 6 Figure 10 PC software installation 6 of 6 Installation complete...

Страница 9: ...the USB kit skip this step if the PCI kit is used 2 Connect the 9 pin D SUB connector of the STIM202 communication and power cable to the USB cable Tighten the screws of the STIM202 communication and...

Страница 10: ...der from Windows start menu Click on the shortcut named STIM202 EVK to start the PC software For full functionality run program as administrator Figure 12 Starting PC software from Windows 7 start men...

Страница 11: ...s Fill in the four open fields and click Submit The default email client opens Press Send in order to complete this step and the user information is sent back to Sensonor Figure 14 Welcome message and...

Страница 12: ...lick OK to confirm when the correct COM port s is are selected Figure 16 Editing the INI file in order to verify the correct COM port settings 5 Establish connection to module by clicking the Connect...

Страница 13: ...ication and power cable into a free USB port of the PC laptop Confirm the supply voltage applied by clicking OK on the pop up message Figure 18 Normal mode panel when USB connector of STIM202 communic...

Страница 14: ...202 Evaluation Kit DOK333 rev 06 14 22 Dec 2017 7 Introduction to PC software 7 1 Panels overview In addition to the panels already shown Normal mode and Parameters panel other panels are also availab...

Страница 15: ...USER MANUAL EvaluationTool STIM202 Evaluation Kit DOK333 rev 06 15 22 Dec 2017 Figure 21 Measure panel Figure 22 Logging panel for saving data to file...

Страница 16: ...this triggers an update of this view File Open parameter file For opening and taking a specific INI file into use File Save parameter file as To save parameters into an INI file File Print parameters...

Страница 17: ...esponses from the gyro module 7 4 Service mode panel descriptions Service mode is used for gyro module configuration Service mode is entered by clicking on the Service mode tab next to the Normal mode...

Страница 18: ...am content to be shown Several options are available depending on the active datagram type Use the arrows in the left side of box to scroll between available selections The plot updates immediately if...

Страница 19: ...ts data logging Stop button Stops data logging Stop criteria slide User selections between manually no of samples and Time elapsed for stopping a measurement series Samples box In use when defining a...

Страница 20: ...00 bits s option while the PCI card of the PCI kit supports all available bit rates RS422 Stopbit 1 or 2 Default is 1 RS422 parity None odd or even Default is None External Hardware The GPIB Card Numb...

Страница 21: ...o command sent 9 No serial number datagram received Even after reties the expected datagram is not received as response to command sent 10 No datagrams received Failed to acquire the requested number...

Страница 22: ...the device if you change to something else than supported 460800 b s For the PCI card there are no worries it supports all available bit rates A warning to the user about limitations for certain RS42...

Отзывы: