Sensocar SC-A1 Скачать руководство пользователя страница 6

 

- 6 - 

 

 

Environment 

Key 

Descriptions (standard functions) 

Always 

ON/OFF 

With the equipment power off, pressing the key turns the equipment on. 
With the equipment power on, 

long press

 the key (more than 2 seconds) turns the 

equipment off. 

Entering data 

of 3 figures 

or less 

Increase

. Keeping it pressed down for a few seconds 

increases  10  by  10

 when the lights 

scroll is completed. 

Decrease

. Keeping it pressed down for a few seconds 

decreases 10 by 10

 when the lights 

scroll is completed. 

FUN 

Leave

INTRO 

Save

 and 

exit

Entering 

data 

digit by 

digit 

Increase

 digit. 

Change

 the digit to be modified (indicated by the corresponding decimal point).

 

FUN 

Leave

INTRO 

Save

 and 

exit

Weighing 

Carries out 

tare / tare lock / tare unlock

Zero is set. If there is a tare, the weight display mode is: 

net/gross

FUN 

Special

 key

 to combine with any of the others: 

-

T

: Enter 

manual tare 

/ r

elays menu 

(if active) 

-

B

Functions menu

 

-

ENT

Totalise 

If  the 

Piece  Counter

  option  is  active,  pressing 

during  scroll

 

will  switch  between 

weight/pieces. 

INTRO 

The  weighing  is  accumulated  and 

printed

.  If  there  is  an  active  dosing  programme,  the 

START/STOP

 function is carried out. 

 

Содержание SC-A1

Страница 1: ...SC A1 Manual User SC A1 Advanced weighing equipment with ABS or INOX finish high contrast LED or backlit LCD display and 5 key keyboard 2017 02 14 COMPLETE USER MANUAL...

Страница 2: ...2...

Страница 3: ...on of serial weighings Automatic totalling of serial weighings Accumulated Grand Total Configurable number of lines to finish ticket and delays per printed line Repeat ticket and optional ticket per w...

Страница 4: ...11 3 1 2 Stability 11 3 1 3 Quick tare 12 3 1 4 Gross weight net weight 13 3 1 5 Tare lock 13 3 2 Manual tare 14 3 3 Extended accumulation and totalisation of weighings 15 3 3 1 Manual accumulation 15...

Страница 5: ...5 1 DISPLAY AND KEYBOARD DESCRIPTION Stability Zero Tare Tare lock Gross Piece counter Non metrological Low battery ON OFF On Off T Tare B Zero Gross FUN Function INTRO Enter Print...

Страница 6: ...l is completed FUN Leave INTRO Save and exit Entering data digit by digit T Increase digit B Change the digit to be modified indicated by the corresponding decimal point FUN Leave INTRO Save and exit...

Страница 7: ...o NU ACUM Number of accumulations before automatic totalling 0 255 accumulations W UNIQ Single weighing mode selection Yes No There will be a complete ticket for each weighing and also when totalising...

Страница 8: ...INTRO to save FUN to leave DATE Displays the current date DD MM YY INTRO to edit T B to modify 6 decimal digits INTRO to save FUN to leave CELLS Display points and weight of each load cell Only in equ...

Страница 9: ...s digits and pilots The equipment identifier is then displayed Then if the equipment has dead weight units with weight module or digital cell communication the counter value is shown the number of tim...

Страница 10: ...Ordinary weighing Net gross tare tare lock By defect the unit will start up showing the weight on the platform Both the text of the banner displayed when starting up the unit and the headers and foot...

Страница 11: ...tions The speed with which the changes and the degree of weight stability shown are displayed depend on the values set in the filter parameters Options STAB T FILTER and FIL DEP in the Programming Men...

Страница 12: ...zero pressing the T key again causes the unit to carry out a new Tare The Quick Tare function it s only available when the number of divisions of gross weight is bigger than the one defined in the min...

Страница 13: ...ght is removed from the platform deleting and re displaying the gross weight 3 1 5 Tare lock To prevent tare from being disabled when all the weight is removed from the platform press the T key a seco...

Страница 14: ...d leave without validating and the ENTER key to validate the tare value entered taring the unit whilst locking the Tare When a manual tare is active printing the tare on a ticket will be accompanied b...

Страница 15: ...y out weighing there must be stable weight which exceeds the value defined as minimum weighing with the weight dropping below the minimum weight necessary to carry out weighing at some point since las...

Страница 16: ...NT key to display the message The unit then briefly displays the number of weighings accumulated so far in our case the first And the accumulated weight subtotal which in our case since it is the firs...

Страница 17: ...s a frame to be sent with the weight on the platform at this moment In order to carry out a new weighing and continue accumulating remove the weight from the platform and place the new weight to accum...

Страница 18: ...en doing this the screen display switches between the total number of weighings made and the total weight accumulated returning to weight mode by pressing any key For example if 4 weighings are carrie...

Страница 19: ...t of 0 081 kg has been entered and accumulated Totalised by pressing FUN ENT 3 4 Piece counter In piece counter mode the unit calculates and displays at all times the number of pieces resulting from d...

Страница 20: ...it can switch between weight and piece counter modes by pressing the FUN key The unit enables the pilot to indicate that the value shown on screen corresponds to a number of pieces and not to a weight...

Страница 21: ...se the value of the flashing digit the B key to change digit the FUN key to cancel editing and leave without saving and the INTRO key to validate and save the piece value entered The unit will very br...

Страница 22: ...NT The ticket resulting from the operations with pieces has the following format This indicates the unit weight of the pieces the weight and number of the pieces of each weighing and the total totalis...

Страница 23: ...weighings so that the information relative to the latest 500 000 weighings can always be recovered The information of the memory is organized depending on the number of Ticket to which the weighing be...

Страница 24: ...played Once the ticket number has been introduced the equipment searches on the DSD memory the relative data to this ticket In case it does not find any associated weighing the following message is di...

Страница 25: ...5 and the total accumulated weight By pressing T and B keys we will be able to move through the various weighings First of all the number of weighing is displayed and afterwards the recorded net weigh...

Страница 26: ...by pressing INTRO key the printing of the ticket copy is initiated at the same time that the flashing message Print is displayed to indicate that a printing is being made Finally FUN key exits the dat...

Страница 27: ...27 Electromagnetic susceptibility has been certified in tests conducted with field strength of 10 V m in accordance with new regulations...

Отзывы: