Sensit STHC 102 Скачать руководство пользователя страница 7

 

Default Parameters: 

Baud Rate 

9600 bps, 13 dec 

Stop Bits 

Temp sensor corr 

-

2,9 °C 

Data Bits 

Module Address 

0x01 

RH sensor corr 

7,6 % 

Parity 

None 

Module ID 

0xF204 

CO2 sensor corr 

--- 

Settings 

Autocalibration enabled, CO2 power enabled   

 

 

 

Declaration of Conformity 

SENSIT s.r.o. provides the product with the 

EU Declaration of Conformity

  issued according to Act No. 90/2016 Coll. 

and Act No. 22/1997 Coll.,

 

as subsequently amended. The product is in accordance with the following directives: 

 

European  Parliament  and  Council  Directive  2011/65/EU  of 8  June  2011  on  the  restriction  of  the  use  of  certain 
hazardous substances in electrical and electronic equipment  

 

European Parliament and Council Directive 2014/30/EU of 26 February 2014 on the harmonisation of the laws of the 
Member States relating to electromagnetic compatibility 

Storage, delivery, complaints and repairs: 

The sensors can be  stored at place with a

mbient temperature 5 to 40 °C and relative humidity 5 to 85% 

Each  delivery  contains  the  following  unless  otherwise  agreed  by  the  customer  sensor  according  to  purchase  order, 
Instruction Manual, including Guarantee Certificate and Delivery Note 

Guarantee  and  after-guarantee  repairs  of  sensors  are  ensured  by  the  manufacturer.  The  product  must  be  delivered 
including  a  copy  of  the  Guarantee  Certificate,  duly  packed  and  fit  to  shipment  so  as  not  to  get  damaged  during 
transportation.

 

GUARANTEE CERTIFICATE 

The product is covered by guarantee for 24 months from the date of purchase.

 

In  this  period,  the  manufacturer  will  remove  all  material  or  manufacturing  defects  arisen  demonstrably  during  the 
applicable warranty period. The manufacturer is liable for the technical and operational parameters of the product given 
in the user manual. Any identified defects will be claimed by the buyer without undue delay after their identification or, as 
appropriate, after  the buyer  was able  to  identify  them  during  his  routine care.  A completed Warranty Certificate  with a 
brief description of the defect plus the product must be submitted with the claim.  

Warranty does not cover a product: 

  That was damaged during transport and inappropriate storage, improper commissioning and/or that has been used for 

a purpose other than specified 

  That has been used in an improper manner, inconsistent with the user manual and/or generally applicable technical 

standards or safety regulations  

  That is worn or damaged as a result of normal use of the product, without loss of its operational characteristics and 

guaranteed technical parameters 

  Into  which  unskilled  intervention,  unauthorised  structural  or  other  changes  (reprogramming,  resetting  of  set 

parameters, etc.) have been made 

  That  is  mechanically  damaged,  e.g.  by  fall,  being  hit  by  a  hard  object,  cleaning  with  unsuitable  agents,  power  cord 

tearing/breaking, breaking or other damage of individual product parts 

  That  has  been  exposed  to  adverse  external  influence,  e.g.  object  intrusion,  wrong  supply  voltage,  influence  of 

chemical  processes,  electrical  surge  (obviously  burnt  components  or  printed  circuits),  dusty,  dirty,  aggressive  or 
otherwise unsuitable environment, except normal variation 

  That has been damaged by an incidental or natural disaster or as a result of natural or external phenomena, such as 

storm, fire, water, excessive heat 

  That is claimed without the Warranty Certificate or nameplate. 

Rights  and  obligations  regarding  the  rights  arising  from  defective  performance  will  be  governed  by  the  applicable 
legislations and the applicable Business Terms and Conditions of SENSIT s.r.o. and this Warranty Certificate. 

Date of sale confirmation:

 

Serial number: 

 

 

Содержание STHC 102

Страница 1: ...ercial Register administered by the Regional Court in Ostrava Section C Entry 13728 sensit sensit cz www sensit cz 8500 2 06 17 Replaces 8500 1 USER MANUAL STHC 102 COMBINED TEMPERATURE RELATIVE HUMID...

Страница 2: ...sistance of the sensor head including electronics Recommendation for sensor use and positioning The sensor is suitable for the measurement of temperature humidity and concentration of carbon dioxide s...

Страница 3: ...and a minimum length of 30 mm During this operation take care to prevent mechanical damage of the sensing element refer to Cover removal use the left hand to firmly grasp the base bottom of the box in...

Страница 4: ...d accuracy is achieved within 0 5 hours after power connection For a short period the sensor may be exposed to temperatures ranging from 40 to 80 C Temperature measurement range 0 to 45 C With guarant...

Страница 5: ...short circuited bit 4 EEPROM initialization when writing bit 4 to 1 SWITCH must be disconnected indicated by bit 2 in MSB SW reset can be performed by writing the register SW reset adr 1002 status MSB...

Страница 6: ...erve 13 MSB 14 LSB reserve 14 MSB Temp sensor 15 LSB R W EEPROM temperature sensor correction in 0 01 C 16bit signed value corr 15 MSB 2 9 C self heating effect of electronics RH sensor 16 LSB R W EEP...

Страница 7: ...of the product given in the user manual Any identified defects will be claimed by the buyer without undue delay after their identification or as appropriate after the buyer was able to identify them d...

Отзывы: