SENSIRION EK-F3 Series Скачать руководство пользователя страница 5

EK-F3 Evaluation Kit 

 

 

Figure 4: 

Pop-up window for proper connection of the EM1 to the FlowViewer 2.2 

 
Once the connection has been set up, the FlowViewer main window will appear (see Figure 5), allowing 

mass flow to be displayed. Measurements are started with the START button and interrupted with the 
STOP button. 

You will notice that the EM1 is displayed as ASF1430/ASL1430.The reason for this is that the EM1 uses 
the same software in its microprocessor as the ASF/ASL1430 series. 

The different full scale versions of the EM1 (500 mln/min, 20’000 mln/min = 20 ln/min and 200 ln/min) can 
be recognized by the values of the y-axis on the left side graph and the given unit in the “Flow Reading” 

section. Samples for each version are shown in Figure 5 to Figure 7. 
In the section “Sensor Settings” the sampling rate, data format and modus can be set. Depending on power 

supply and heat dissipation the sensor temperature can be a few degrees above room temperature. 
The section “Chart Setting” allows you to configure the graphs. If “Integrating” is on, information about ac-

cumulated volume and peak flow is displayed. 
The left side shows the full meter range and the right side shows a selectable zoom area. The zoom factor 

and the level shift can be set by the selectors above the graph. 
 

 

 

Figure 5: 

FlowViewer displaying measurement data of the EM1_L (500 mln/min) 

www.sensirion.com 

 

Page 5 of 7 

Содержание EK-F3 Series

Страница 1: ...ction _ What You Need to Get Started _ Installing the Hardware _ General Measurement Setup _ Installing the Software and Start Up _ Software Overview Flow Viewer _ Disclaimer www sensirion com Sensiri...

Страница 2: ...illustrate the unique features of the sensor system and to adapt it to your specific application The contents of the kit are listed below see Figure 1 and Table 1 It includes one EM1 meter a serial in...

Страница 3: ...mplete the following steps see Figure 2 1 Turn off your PC Keep your PC plugged in so that it remains grounded while you install the EM1 2 Connect the serial interface cable with the COM port of your...

Страница 4: ...NT XP 2 Open the file DISKS double click SETUP EXE and follow the instructions of the installation wiz ard 3 Start with Start Programme Sensirion AG Sensiview_v2_2 or through the path where you in sta...

Страница 5: ...cognized by the values of the y axis on the left side graph and the given unit in the Flow Reading section Samples for each version are shown in Figure 5 to Figure 7 In the section Sensor Settings the...

Страница 6: ...3 Evaluation Kit Figure 6 FlowViewer displaying measurement data of the EM1_R 20 000 mln min 20 ln min Figure 7 FlowViewer displaying measurement data of the EM_V 200 ln min www sensirion com Page 6 o...

Страница 7: ...echnical experts SENSIRION AG reserves the right without further notice to change the product specifications and or information in this document and to improve reliability functions and design CMOSens...

Отзывы: