SPECIFICATIONS
General Specifications
Controls ......................................................... Power Switch, Flow Control (all models), plus:
MODE/HOLD button (Clock Timer Model)
MODE/HOLD, PROG,
▲
, &
▼
buttons (Program Timer Model)
Indicators ...................................................... Display (LCD), Battery (Green) LED, Fault (Red) LED
Display Ranges .............................................. 0–9999 (Timing), 0–9 (Error Percentage)
Display Messages .......................................... LAST, CAL, SHUT/OFF (Clock Timer & Program Timer Models)
E, PC, P1–P6, OLD (Program Timer Model)
Dimensions (GilAir-3) .................................. 3.6” (H) x 3.9” (W) x 2.0” (D)
90 mm (H) x 100 mm (W) x 51 mm (D)
Dimensions (GilAir-5) .................................. 4.1” (H) x 3.9” (W) x 2.0” (D)
103 mm (H) x 100 mm (W) x 51 mm (D)
Weight (GilAir-3) .......................................... 21 oz. (595 g)
Weight (GilAir-5) .......................................... 22.5 oz. (638 g)
Power Supply
Battery Pack .................................................. GilAir-3: 4.8 volt, 1.8 amp hour
GilAir-5: 6 volt, 1.8 amp hour
Battery Type .................................................. Rechargeable Nickel-Cadmium
Battery Charge Time ..................................... 14–18 hours
Expected Battery Life † ................................. 300–500 charge/recharge cycles
Estimated Battery Life † ................................. 2.5 years (< 20 hours weekly use)
1.5–2.5 years (20–39 hours weekly use)
1–1.5 years (40–60 hours weekly use)
†
Inactivity for extended periods may shorten nickel-cadmium battery life.
Battery life estimates are based on proper battery maintenance.
Operating Specifications
Constant High Flow Range .......................... GilAir-3: 850–3000 cc/min
GilAir-5: 850–5000 cc/min
Flow Control ................................................. External Flow Adjust (
±
5% of set point)
Constant Flow (Low Flow) ........................... 5–500 cc/min to 25” H
2
0 (640 mm Hg)
Multi-Flow (Low Flow) ................................. 1–750 cc/min, to 18”+3” H
2
0 (460+80 mm Hg)
Pressure Range
w
o
l
F
p
m
u
P
)
0
2
H
”
(
n
u
R
.
r
H
8
t
l
u
a
f
e
r
o
f
e
b
O
2
H
”
.
n
i
M
)
M
P
L
(
3
-
r
i
A
li
G
5
-
r
i
A
li
G
3
-
r
i
A
li
G
5
-
r
i
A
li
G
5
8
.
0
0
2
0
2
5
2
5
3
1
5
2
5
2
0
3
5
3
2
–
6
2
–
5
3
5
.
2
5
1
–
0
2
–
3
8
3
2
0
1
0
3
4
–
5
1
–
5
1
5
–
8
–
8