SenseAir tSense Скачать руководство пользователя страница 13

 

 

 

12 

 

Support 

 
The quickest way to obtain technical support is via email. Please send all support 
inquires to support@co2meter.com.  
 
Please include a clear, concise definition of the problem and any relevant 
troubleshooting information or steps taken so far, so we can duplicate the problem 
and quickly respond to your inquiry. 
 

Warranty 

 
This meter comes with a 5 YEARS (warranty period) limited manufacturer’s warranty, 
starting from the date the meter was shipped to the buyer. 
 
During this period of time, CO2Meter.com warrants our products to be free from 
defects in materials and workmanship when used for their intended purpose and 
agrees to fix or replace (at our discretion) any part or product that fails under normal 
use. To take advantage of this warranty, the product must be returned to 
CO2Meter.com at your expense. If, after examination, we determine the product is 
defective, we will repair or replace it at no additional cost to you. 
 
This warranty does not cover any products that have been subjected to misuse, 
neglect, accident, modifications or repairs by you or by a third party. No employee or 
reseller of CO2Meter.com’s products may alter this warranty verbally or in writing. 
 

Liability 

 
All liabilities under this agreement shall be limited to the actual cost of the product 
paid to CO2Meter.com. In no event shall CO2Meter.com be liable for any incidental 
or consequential damages, lost profits, loss of time, lost sales or loss or damage to 
data, injury to person or personal property or any other indirect damages as the 
result of use of our products. 
 

Returns 

 
If the product fails under normal use during the warranty period, a RMA (Return 
Material Authorization) number must be obtained from CO2Meter.com. After the item 
is received CO2Meter.com will repair or replace the item at our discretion. 
 
To obtain a RMA number, call us at or email us at (386) 256-4910 
support@co2meter.com. When requesting a RMA please provide reason for return 
and original order number. 
 
If we determine that the product failed because of improper use (water damage, 
dropping, tampering, electrical damage etc.), or if it is beyond the warranty date, we 
will inform you of the cost to fix or replace the product. 
 
For more information visit our website: www.CO2Meter.com/pages/faq 
 
 

Содержание tSense

Страница 1: ...0 CO2 Temperature and Relative Humidity Transmitter tSense Touch Screen User s Manual ...

Страница 2: ...odified from PC Windows software UIP version 5 or higher and USB communication cable alternative via Modbus or BACnet Table of Contents General 1 Display menu 2 Measured values 2 CO2 Temperature Humidity 2 Limit settings 2 CO2 Temperature Humidity 2 Display appearance 3 CO2 Temperature Humidity Char 3 Brightness 3 Background 3 Sleep scheme 4 Toggle Time 4 Temperature and PIN selection 5 Output con...

Страница 3: ...2 MEASURED VALUES CO2 Temperature Humidity LIMIT SETTINGS CO2 Temperature Humidity CO2 Orange Red limit Temp Humidity Orange Red limit same method as CO2 Orange Red limit 100 200 300ppm ...

Страница 4: ...3 DISPLAY APPEARANCE CO2 Temperature Humidity Chart 24h Week Brightness Background Sleep Scheme Toggle Brightness 10 20 100 Background ...

Страница 5: ...4 Sleep scheme 3 4 5 10 s Toggle time ...

Страница 6: ...5 Temperature unit selection Change PIN code ...

Страница 7: ...label OUT 2 0 10 VDC 0 50oC See label See label OUT 3 0 10 VDC 0 100 RH See label See label Table 1 Default output configurations of tSENSE Figure 1 Terminal The sensor is supplied with 0 10VDC linear outputs for Out 1 Out 2 and Out 3 see Table 1 Alternative output ranges can be configured with PC software UIP version 5 or later see below Figure 2 Connection to PC ...

Страница 8: ...load software UIP5 Download software UIP version 5 or higher at www senseair se products software uip 5 Check for updates Run until For more information see Help in the UIP5 program Connection configurations ...

Страница 9: ...8 Changing Modbus BACnet Network Address Modbus address BACnet MACaddress CO2 ABC ...

Страница 10: ...ation against failure by checking valid dynamic measurement ranges All EEPROM updates initiated by the sensor itself and by external connections are checked by subsequent memory read back and data comparisons System checks returns error bytes to RAM Error codes are available by connecting the sensors to a PC with a special USB cable art no 00 0 0070 connected see fig 2 Error codes are shown in sof...

Страница 11: ...r will use CO2 sensor temperature if RH T Temperature is unavailable S_Temp will be set to NTC_Temp 6 7 8 Output config error Error in output configuration Output is still updated i e can be 0 10V Check connections and loads of outputs Check detailed settings and configuration with UIP software version 5 or later Contact local distributor Table 2 Error codes and action plans Note 1 Occurs if probe...

Страница 12: ...s have occurred Software can be downloaded free at www CO2Meter com USB cable and zero calibration kit can be ordered from CO2Meter For change of control parameters and re calibration CO2 temperature and relative humidity the software must be used Checking can be done on site without interfering with ventilation system Background calibration Press button in hole to the right in bottom 15s until gr...

Страница 13: ...ident modifications or repairs by you or by a third party No employee or reseller of CO2Meter com s products may alter this warranty verbally or in writing Liability All liabilities under this agreement shall be limited to the actual cost of the product paid to CO2Meter com In no event shall CO2Meter com be liable for any incidental or consequential damages lost profits loss of time lost sales or ...

Страница 14: ... com Address CO2Meter Inc 131 Business Center Drive Ormond Beach FL 32174 USA This product is in accordance with the EMC 2004 108 EC 92 31 EEG RoHS 2011 65 EU Including amendments by the CE marking Directive 93 68 EEC The product fulfils the following demands EN 61000 4 2 level 2 EN 61000 4 3 level 2 EN 61000 4 4 level 4 EN 61000 4 6 EN 61000 4 8 level 4 EN 55022 class B ...

Отзывы: