SensComp SonaSwitch MINI-A Скачать руководство пользователя страница 2

 

 

SonaSwitch

®

The SonaSwitch® MINI-A is now calibrated to 
your desired target distance for full scale 
analog voltage output. 

 
 
 
 
 
 
7. 

Minimum Voltage Range Setting. 

  Place the target at the desired distance for the 

minimum voltage output.  This can be either 
the minimum distance or the maximum 
distance between the sensor and the target 
(see step 5 above). 

  Depress and hold the “MIN RANGE SET” 

push button, and wait for the “RANGE 
WINDOW LED” indicator to stop flashing and 
the transducer generates a “chirp” sound. 

 

Note: The minimum voltage output will be a 
value between 0.01 and 0.05 volts (50 mv), 
due to the analog output’s amplifier offset 
voltage. 

  The SonaSwitch® MINI-A is now calibrated to 

your desired target distance for zero analog 
voltage output. 

8. Gain Adjustment 

Note: The “GAIN” potentiometer has been preset 
at the factory to provide the best performance for 
the range of your SonaSwitch® MINI-A.  In the 
event that it is changed, the steps below will 
assist you in returning it to the proper value 

  To calibrate the “GAIN” setting, place the 

target at the maximum desired detection 
distance.   

  Rotate “GAIN” pot fully counter clock-wise 

(CCW).   

  Slowly rotate “GAIN” pot clockwise (CW) until 

detection occurs. 

  Rotate “GAIN” pot clockwise (CW) an 

additional 1/16 turn. 

   

Note:  Always calibrate “GAIN” for minimum 

gain required for reliable detection.  Excessive 
gain may result in false target detection.

 

9.  Range Window LED 

The Range Window LED performs two 
indication functions: 

  During Setup procedures, the LED will flash 

as the set-up values are programmed into the 
sensor. 

 During 

normal 

operation, 

the LED will illuminate, 

indicating that a target is detected between the 
“Minimum  Range Set” point and the “Maximum 
Range Set” point. For targets outside this range, 
the LED will be off. 

10. Range Output 

The range output indicates when a target is   
being detected between the MIN and MAX range 
setting. 

 
 
 

 

 

 
 
 
 
 

 
 
 
 
 
 

 

SonaSwitch® MINI-A & 

SonaSwitch® MINI-AE 

 

Push Button Settable 

Ultrasonic  

Sensor 

 
 

Installation and 

Operation 

Manual 

 

Отзывы: