Sensata Magnum Energy MSH Series Скачать руководство пользователя страница 2

2

© 2018 Sensata Technologies

 MSH Control Board Removal and Replacement

Figure 2, Top View of an MSH Control Board

3.0 

Removing and Replacing the MSH 

 

 

Series Control Board

This section provides information on removing and 

replacing the control board in a MSH Series inverter.

3.1 

Removing the MSH Series Control Board

1.  Remove the MSH inverter’s top cover and review the 

internal components as shown in 

Service Instructions: 

64-1007

 – 

MSH

 

Top Cover Removal and Replacement 

with Internal Component Identifi cation

.

2.  Locate the MSH Series control board in the inverter 

(Figure 2, Item A), and then remove the two #6-32 

screws securing it to the inverter base (Figure 1).

3. Remove the Phillips screw and the ¼-20 bolt 

(7/16” head) that connect the FET and transformer 

busbars to the MSH’s control board, respectively 

(Figure 2, Items B & D).

4.  Grasp the control board by its top edge (or upper 

corners) and 

fi

 rmly pull up to remove it from the 

bottom 16-pin FET board connector.

5.  Locate and disconnect the 16-pin ribbon connector. 

See Figure 2, Item C.
The MSH control board is now removed. Using 

ESD precautions, place it component-side up on a 

grounded, static-free surface until it can be placed 

in an antistatic bag to be returned with any other 

replaced components.

Control

Board

(vertical)

Phillips Screw

B

¼-20 Bolt

(7/16” head)

D

16-Pin Ribbon 

Connector

 

(red line on top)

C

A

3.2 

Replacing the MSH Series Control Board

Note:

 

If the FET board also needs to be replaced, 

follow the information described in 

Service Instructions: 

64-1005 –

 

Large FET Board Removal and Replacement, 

before replacing the control board.

1.  Remove the new control board from its antistatic bag, 

and then connect the 16–pin ribbon cable connector. 

Before pushing in the connector, ensure it is seated 

with the red stripe on the ribbon cable facing toward 

the rear of the inverter and the connector pins are 

aligned correctly.

2. Insert the new control board into the bottom 

16-pin connector located on the FET board. Ensure the 

connector pins are aligned correctly before pushing in.

3.  Replace the two #6-32 screws (T15 head) to secure 

the new control board to the FET board.

4.  Reconnect the Phillips screw and the ¼-20 bolt

 

(7/16” head) that connect the MSH’s control board 

to the FET and transformer busbars, respectively 

(Figure 2, Items B & D).
The new control board is now installed, review all the 

connections a 

fi

 nal time and ensure they are correct.

5.  If there are no other internal components to replace, 

reinstall the top cover as described in 

Service 

Instructions: 64-1007

 – 

MSH

 

Top Cover Removal and 

Replacement with Internal Component Identifi cation

.

Отзывы: