![Sensata Dimensions 12LP15 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/sensata/dimensions-12lp15/dimensions-12lp15_owners-manual_1243177007.webp)
Page 7
Intr
oduction
12LPC Manual
Specifications
All ratings above assume 12.6 VDC nominal voltage, 25°C ambient temperature, and the inverter is mounted in free
air. 12.6 VDC is to be measured at the inverter input terminals.
For use at ambient temperatures less than -20°C, use the hardwire connections. The GFCI may not properly operate
at temps below -20°C.
At temperatures greater than 25°C, the inverter output is de-rated. See graph in “Operation” section of the manual.
LP units operate in inverter mode only. LPC units are able to operate in inverter mode and charge mode with
bypass.
Input Voltage (VDC)
10.5 – 15.0
DC Surge Voltage (VDC)
Up to 24 VDC
Output Voltage (VAC)
120 +/- 5%
Output Frequency (Hz)
60 +/- .05%
THD
< 5% at 12.6 VDC and 1500W
Output Waveform
Pure Sine < 5% THD
Output Power (Watts Cont.)
1500
Output Current (AAC Cont.)
12.5
Input Current (ADC Cont.)
Up to 167 at 12.6 VDC
Input Current (ADC Cont.)
Up to 190 at 10.5 VDC
Peak Power (Watts)
3000
Peak Output (AAC)
25.0
Motor Starting Rating (h.p.)
1/2
Inverter Efficiency
Up to 80%
Charger Input Voltage (Vrms)
85 – 135 (LPC only)
Max Charger Output Current (ADC)
65 at 12.6 VDC (LPC Only)
Input Current Bypass (Arms)
20 (LPC Only)
Weight (lbs.)
30
Dimensions in. (L x W x H)
19.0” x 9.75” x 4.8” *
Operating Temperature
-40°C to 50°C (-40°F to 122°F) **
Agency Listings
UL458, E100666
Table 1 Specifications
* Length includes DC terminals and handle.
** At ambient temperatures above 50°C, the inverter/charger may fail to restart in the event it shuts down in an
over temperature condition.