ELECTRICAL ACCESSORIES

GZL 1019 A1

Connection cable

For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 1 m.

GZL 1019 A5

Connection cable

For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 5 m.

GZL 1019 A10

Connection cable

For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 10 m.

GZV 1019

BNC coupler

For connecting two connection cables GZL 1019 A1, -5, -10.

N.B.: „INFRA-RED

If you consider using a transmission system with high power IR radiators

PLANNING BROCHURE“

SZI 1029 the „Infra-red Planning Brochure“ from Sennheiser is available.

FROM SENNHEISER

Besides  in-depth  information  on  infra-red  transmission  technology  it
contains application examples and lists with combinations and overviews
for infra-red system planning.

Since we are continually trying to improve our products it may happen
that some technical alterations are made on the described products after
these operating instructions have gone to press. We apologise for any
inconvenience.

TECHNICAL SPECIFICATIONS

SZI 1029 (SZI 1029-10)

Number of radiator diodes

144 (288)

Approximate radiating power

5 W (10 W)

Wavelength of radiated
infra-red light approx.

880 nm

Carrier frequency range

30 kHz - 6 MHz

IR input

50 mV - 3 V / approx. 5 k

Input/output connections

BNC sockets

Switching treshold for
automatic on/off function

50 mV

Operating voltage

...-120

85 - 265 V 

±

 10 %, 50 - 60 Hz

...-EU

85 - 265 V 

±

 10 %, 50 - 60 Hz

...-UK

85 - 265 V 

±

 10 %, 50 - 60 Hz

...-24

24 V min., ideally 25 - 35 V DC

Current consumption ...-120

approx. 610 mA (1A) with 120 V

...-EU approx. 350 mA (700 mA) with 230 V

...-UK approx. 350 mA (700 mA) with 240 V

...-24

approx. 1.6 A (3.2 A) with 24 V DC

Stand-by

60 mA max.

Mains fuse for 120/230/240 V

2 A, anti-surge type

in the IEC mains socket

Fuse for 24 V

DC 2 A, anti-surge type

Dimensions in mm

250 x 180 x 80 (250 x 288 x 80)

Weight

approx. 2.1 kg (approx. 3 kg)

Supply schedule

1 radiator
1 mains cable (2.5 m)

UL-No. (only for 120 volt
USA version)

to be advised

Содержание SZI 1029-10-120

Страница 1: ...wer during multi channel operation 30 Computing the radiating power 31 Propagation of infra red light 31 Putting the radiator into operation 32 Mains connection 32 Connecting an IR radiator 33 Single Multi channel operation 33 Cancellation with greater cable lengths 34 Malfunction indicator 35 Operation indicator 35 Distance between radiators and receivers 35 Installation 35 Suitable modulators 36...

Страница 2: ...fra red radia ting power 5 W single channel MONO or multi channel MUlTI operation BNC output socket for connection of additional SZI 1029 or SZI 1015 radiators Black housing Supplied with a European mains cable SZI 1029 EU W As SZI 1029 EU but white with unpainted aluminium housing SZI 1029 120 As SZI 1029 EU but supplied with a USA mains cable SZI 1029 UK As SZI 1029 EU but supplied with a UK mai...

Страница 3: ...malfunction indicator Selector switch for single channel MONO multi channel MULTI operation BNC infra red input socket BNC output socket for connecting further radiators Thread for mounting the radiator IEC mains connector 24 V DC input socket only with 1029 24 model CONNECTING SEVERAL RADIATORS WIDEBAND AND NARROW BAND TRANSMISSION SINGLE CHANNEL AND MULTI CHANNEL Starting with an infra red modul...

Страница 4: ... up to 32 mono channels with a slightly reduced audio frequency response They are ideal for multi channel interpretation systems and multilingual information systems AREAS OF APPLICATION P Conference and simultaneous interpretation systems P High quality cordless sound transmission in recording studios or for hi fi systems IMPACT OF CURTAINS Dark and heavy materials curtains carpets panellings and...

Страница 5: ... channel surface area in sq m x number of channels 1300 COMPUTING THE During single channel operation switch set to MONO every RADIATING POWER SZI 1029 radiator will supply an area of about 1000 sq m The SZI 1029 10 radiators are able to supply approximately double this area When switched to narrow band multi channel operation switch set to MULTI power output and thus irradiated area are reduced b...

Страница 6: ...onnected to one another using a BNC coupler GZV 1019 A IR output BNC for extension radiators For permanentlyinstalledsystems you should use commercially available 50 Ω coaxial cables such as RG 58 75 Ω cables can be used if 50 Ω cables are unavailable If you want to use several SZI 1029 radiators you have to connect them in series This is done by connecting the output BNC socket of the first radia...

Страница 7: ...een one thus indicating that the device will have to be repaired OPERATION INDICATOR The indicators work as follows Red Indicator Only The radiator is connected to the mains but there is no IR signal present Green Indicator Only IR signal is present the radiator is working normally Red Green Indicator FAULT CONDITION 30 or more of the diodes are not working and the radiator should be returned to y...

Страница 8: ...t receiver additionally RI 250 RI 150 RI 300 RI 500 HDI 302 HDI 380 MZT 14 Mounting bolt For mounting goosenecks and swivel joints with 3 4 threads to table tops GZP 10 Mounting plate For wall and ceiling mounting GZG 1029 Swivel joint For mounting and aligning the radiator used in combination with mounting plate GZP 10 mounting bolt MZT 14 or a stand Interchangeable thread 1 4 3 8 MZT 100 Table s...

Страница 9: ...happen that some technical alterations are made on the described products after these operating instructions have gone to press We apologise for any inconvenience TECHNICAL SPECIFICATIONS SZI 1029 SZI 1029 10 Number of radiator diodes 144 288 Approximate radiating power 5 W 10 W Wavelength of radiated infra red light approx 880 nm Carrier frequency range 30 kHz 6 MHz IR input 50 mV 3 V approx 5 kΩ...

Отзывы: