HME 46-3, HMD 46-3
02/2008
3.4
Disassembly of the microphone arm
Reference: see “Exploded view HME 46-3 / HMD 46-3”, page 21 or see “Exploded view of the cap, microphone
side”, page 24.
1. Rotate the microphone arm (100 or -105) to the side position if necessary (see figure below).
2. Screw the threaded pin (10 of the cap module) completely
into
the microphone arm fixing
.
3. Disassemble the microphone arm (100 or -105) from the cap (20) by moving the microphone
down
towards to the other cap (-25) of the headset
.
100
20
10 (of the cap module)