background image

SCT-1045  Ver. 1.2

5

CAMERA ADDRESS SWITCH SETTING CHART

-ON

-OFF

001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
041
042
043
044
045
046
047
048
049
050
051
052
053
054
055
056
057
058
059
060
061
062
063

128

064

065
066
067
068
069
070
071
072
073
074
075
076
077
078
079
080
081
082
083
084
085
086
087
088
089
090
091
092
093
094
095
096
097
098
099
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

Содержание SCT-1045

Страница 1: ...SCT 1045 Ver 1 2 1 CAMERACONTROLCODE TRANSLATOR VICON RS 422 to VCL RS 485 Ver 1 2 SCT 1045 www sennetech net Sennetech Inc 6455 W Bath Rd Perry MI 48872 U S A Ph 517 675 1150 Fax 517 675 1151 ...

Страница 2: ...2 ...

Страница 3: ...using VCL code from Vicon VPS series controllers It receives Vicon RS 422 commands and transmits the appropriate commands in VCL RS 485 code format There are four independent RS 485 outputs The SCT 1045 will appear to the Vicon controller as a group of responding receiver drivers Internal switches set the low camera number and the high camera number to which the translator will respond The Vicon i...

Страница 4: ...e shows the switch configuration for each address If the Vicon controller can be configured to operate in simplex mode the response line is not required Then the address switches can be set to include the maximum 128 VCL addresses To set the configuration switches remove the back panel which is secured by two screws Then slide the cover back to expose the switches The switches can be changed while...

Страница 5: ...032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063 128 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 ...

Страница 6: ... out Connect to Vicon response line in if needed Connect to power supply REARPANEL INSTALLATION To install the case on the rack mount frame remove the front panel and the plastic bezel The rack mount frame takes the place of the bezel as shown below VCLDATAOUTPUTS VICON CMD IN RSP OUT POWER 9V to 15V AC or DC S S S S S S VICON Power Tx Rx CODE TRANSLATOR ...

Страница 7: ...CL com mands Other commands are converted according to the following table Vicon VCL A P Auto Pan On A I Auto Iris On L S Auto Focus On Aux1 Pan 180 Degrees Aux2 Washer On Aux3 Washer Off Aux4 Wiper On Aux5 Wiper Off Aux6 Manual Change Over Presets Run PP 1 99 Seek Preset 1 99 Pgm PP 1 99 Define Preset 1 99 ...

Страница 8: ...8 December 2008 SCT 1045 Ver 1 2 ...