SenNet Pulse Counter Sigfox
www.satel-iberia.com
3
Type Message
SenNet IoT Pulse Counter Sigfox is an very low power device capable to measure up to 2 impulse input. Client
must select what kind of data will be uploaded to the platform, at depend of number input.
Type 1
:
Counter 1 value
Field
Info
Counter 1 value
Type data
See Table 1
Maximum 65535
Byte
1
2
3
4
Type 2
:
Counter 1 value
Field
Info
Counter 1 value
Counter 2 value
Type data
See Table 1
Maximum 65535
Maximum 65535
Byte
1
2
3
4
5
6
A common point in all types of messages is the head (defined with 2 bytes) that includes important information
embedded in the message (type device/type message/errors.. etc). In the next table are defined the mean of
these info-fields.
Field
Info
Byte
Byte 1
Byte 2
Type Master Device
01 - Easy Meter
02
–
Pulse Counter
03
–
TH (Temp/Hum)
04 - CO2-TH
05 - PM
06
–
GW Modbus
07
–
Not defined
Type Message
type 0 (info)
type 1
→
Counter 1
type 2
→
Counter 1,2
type 3 (not defined)
type 4 (not defined)
..
type 15 (not defined)
Low
le
ve
l Ba
tt
e
ry
H
ig
h
t
e
m
p
e
ra
tu
re
>
5
0
ºC
D
ow
n
lin
k
e
rr
or
Not used
Not used
Feedback Error
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Byte1
Bit 7-6-5
Byte1
Bit 4-3-2-1
Byte1
Bit 0
Byte2
Bit 7-6
Byte2
Bit 5-4-3
Byte2
Bit 2-1-0
Table 1
First message after power on the device is debug message with internal
information about build firmware. This message must be not parser by client
platform, and requeriment a donwlink message for remote settings.
1 input counter
Type 1
Counter 1 value
2 input counter
Type 2
Counter 1 value
Counter 2 value
Type 0
:
debug
message
Field
Info
HW device
Version FW
Revision FW
Not used
Type data
See Table 1
-
Byte
1
2
3
4
5
6-9