Senix Ultrasonic Sensor Скачать руководство пользователя страница 5

Jameco Part number 151482

151482 - Ultrasonic Sensor User's Guide

Getting
Started

Unpacking

Check that you received the following items:

   Circuit board

   Ultrasonic transducer with connecting cable

   RS-232 Computer Cable

   3.5" DOS compatible floppy diskette

   This manual

Specifications

Circuit Board

Power Input

8-24 VDC @ 40 ma.

Range

6 inches to 10 feet

Output

RS-232, Transmit only

Output Format

9600 baud, 8 data bits, 1 stop
bit, no parity

Output Protocol

3 character burst:
#1:55H (sync character)
#2: LSB count data
#3: MSB count data

Resolution

0.013536 inches/count at
room temperature

Temperature

0 to +70 C (32 to 160 F)

Humidity

5-95%, non-condensing

Measurement Period

50 mSec (20 Hz update)

Interface connections

Terminal Block

Transducer connection

2-pin Molex

Weight

1.6 oz.

Size

2.85L x 1.85W x 1.25H

Transducer

Type

Electrostatic Ultrasonic

Frequency

50 kHz

Beam Shape

Conical

Beam Angle

15 degrees total @ 3db down

Temperature

-30 to +70 C (-20 to +160 F)

Board Connection

Blade terminals

Size

1.69" diameter x 0.5" deep

Weight

0.3 oz.

Mounting

Ultrasonic transducer

The transducer mounts in a 1.54" diameter circular hole
cut into any sheet material. The transducer can be glued
using a resilient compound such as GE Silicone Sealant.

Grounding

If the sheet material is metal, surface contact to
the transducer will connect the surface to the
sensor's ground (PWR-). This is allowable as
long as it doesn't conflict with other wiring.

Circuit board

The circuit board mounts on 4 standoffs using 4-40
screws in the following hole pattern:

Senix Corporation, 52 Maple St., Bristol, VT 05443

Page 5

Содержание Ultrasonic Sensor

Страница 1: ...Jameco Part number 151482 Ultrasonic Sensor with RS 232 Output User s Guide Jameco Part Number 151482 Senix Corporation 52 Maple St Bristol VT 05443 1998 by Senix Corporation...

Страница 2: ...er and Release The warranties obligations and liabilities of Senix and the remedies of buyer set forth above are exclusive and in substitution for and buyer hereby waives releases and renounces all ot...

Страница 3: ...ications 4 GETTING STARTED 5 Unpacking 5 Specifications 5 Mounting 5 Beam Pattern 6 Orientation 6 Connections 6 OPERATION 7 Starting the sensor 7 Distance Calculation 7 Software 7 Performance 8 Precau...

Страница 4: ...get Advantages Non contact Measures through the air without touching the target object at relatively large distances Object Ranging Object distance is measured rather than just the presence or proximi...

Страница 5: ...ace connections Terminal Block Transducer connection 2 pin Molex Weight 1 6 oz Size 2 85L x 1 85W x 1 25H Transducer Type Electrostatic Ultrasonic Frequency 50 kHz Beam Shape Conical Beam Angle 15 deg...

Страница 6: ...mating terminals on the transducer The shield end ground should be attached to the terminal of the transducer s outer shell placing the outer shell at ground potential Power Input Connect a 8 to 24 vo...

Страница 7: ...ample program is provided on the included floppy disk that will read the sensor data output and display the measured distance on a personal computer screen The following files are provided on the disk...

Страница 8: ...Keep the beam pattern in mind Keep transducer away from ultrasonic noise sources such as pressurized air nozzles Adjustments Sensitivity This adjusts the electronic sensitivity to the strength of the...

Страница 9: ...broken or shorted wires or loose connectors Common Problems Output stuck at short distance value 1 An object is near the front of the sensor that is being detected possibly associated with the mounti...