MI00138 -E
3
ENGLISH - 2/6
(1):
Maximum error must be increased by 20 µA for input voltages lower than 10 Vac or for direct
voltages.
(2):
The measurement errors are indicated for a sinusoidal signal.
(3):
Acronyms “o.m.” stands for “of measurement”.
Accuracy specifications
(1)(2)
Other Specifications
Range
Measurement error
(3)
100 Vac / 90 Vdc
0,3 % o.m. + 70 µA
200 Vac / 180 Vdc
0,3 % o.m. + 40 µA
300 Vac / 270 Vdc
0,2 % o.m. + 30 µA
400 Vac / 360 Vdc
0,3 % o.m. + 30 µA
500 Vac / 450 Vdc
0,3 % o.m. + 30 µA
Thermal drift
150ppm / K
EMI Error
< 40 µA
Operating conditions:
Temperature: -20..65°C, humidy 30..90 % @ 40°C not-
condensing. Climatic Group III.
Storage Temperature : -20..85 °C.
Altitude: up to 2000 m a.s.l.
International protection: IP20
Weight, dimensions:
140 g, 100 x 112 x 17.5 mm.
Standards:
EN60688 (rated input voltage = 300 Vac)
EN61000-6-4 (
electromagnetic emission, industrial
environment
).
EN61000-6-2 (
electromagnetic immunity, industrial
environment
).
EN61010-1 (
).
safety