Current Output:

Voltage Output:

20 Hz

  to 

1 kHz

4000 V

AC

  power supply / output 

CAT III

 

300

 

V

for installation on 3-phase lines up to 500 V

AC

 

ph-ph

, 300 V

AC ph

-n.

Active or passive: 0

-

20 mA or 4

-

20 mA selectable by internal 

j

umper and DIP-switch.

Maximum load resistance : 600 

.  Protection : 400 W/ms.

 

Available Voltage: < 21 V.
Maximum applicable external voltage (if passive output): 28 V.

 

I

so

lation

:

 power supply / input

 

4000 V

AC 

 

0

-

5 V, 1

-

5 V, 0

-

10 V or 2

-

10 V selectable by internal 

j

umper 

and DIP-switch.
Min

i

mum load resistance: 2500 

. Protection: 400 W/ms

 

Isolation: power supply / input 4000 VAC 

Output Specifications 

Precision @ 25ºC 

(1)

 20

-

400 Hz 

(3) 

400

-

1000 Hz 

(3)

Thermal Stability:

Response Time:

Operating conditions:

LED signal:

Protection degree:

Weight, Dimensions:

0.2 % om

0.4 % om

0.1 % ots

0.2 % ots

< 0.1 % ots

< 0.1 % ots 

Other 

 

(2)

200 ppm/K.

For a stepped variation: max 100 ms from 10 to 90 %.

Temperature:  -10

 to 

65°C,  humidy  30

-

95  %  @  40°C 

not-condensing. Group III.
Storage Temperature : -20

 to 

85 °C

Altitude: up to 2000 m

eters

 a.s.l.

Presence of power supply (green)

IP20.

140 g, 100 x 112 x 17.5 mm

(1):

 These acronyms apply: om = of measurement,   ots = of the scale. 

(2): 

Error caused by electromagnetic disturbances (EMI). 

(3):

 The precision values are indicated for a sinusoidal signal with distortion of < 1%, on current 

reading 4

-

20 mA; errors on the other output scales are increased as follows: by 0.1 % for zero offset 

(0 mA, 0 V), by 0.1 % on fs 5 V and by 0.15 % on fs 10 V.  
The precision indicated in the table can, on request, be provided on another specified scale.

 

Remember that the instrument indicates the average adjusted value in relation to the RMS value. 

Other Specifications

Precision Specifications

EN60688/1997 + A1 + A2
EN61000-6-4/2002-10  (electromagnetic  emission,  industrial 
environment)
EN61000-6-2/2006-10  (electromagnetic  immunity,  industrial 
environment)
EN61010-1/2001 (safety)

Standards:

Frequency

 

Is

o

lation:

 

Overvoltage 
measurement Class: 

Содержание Z201-H

Страница 1: ...ent converter measures the simple harmonic alternating current applied at the input and generates a standard mA or V signal directly proportional to the current measured BLOCK DIAGRAM INPUT OUTPUT CAT III 300 V TECHNICAL SPECIFICATIONS Power Supply Consumption Current Input 85 265 VDC or VAC from 50 to 400 Hz Isolation input output 4000 VAC 2 W at full load 20 mA 230 VAC Power Supply Specification...

Страница 2: ... variation max 100 ms from 10 to 90 Temperature 10 to 65 C humidy 30 95 40 C not condensing Group III Storage Temperature 20 to 85 C Altitude up to 2000 meters a s l Presence of power supply green IP20 140 g 100 x 112 x 17 5 mm 1 These acronyms apply om of measurement ots of the scale 2 Error caused by electromagnetic disturbances EMI 3 The precision values are indicated for a sinusoidal signal wi...

Страница 3: ...NAL JUMPER POSITION OUTPUT SIGNAL SETTINGS The Z201 H instrument transmits a voltage or a current signal The output type voltage or current is set using the internal jumper accessible under the rear side of the the case The signal range is set using the double DIP switch SW1 Current or Voltage Output Selection Current Output F Voltage Output SW1 SW1 J1 J1 Output Range Settings Switch 1 Position Sc...

Страница 4: ...tecollectionprograms Thissymbol foundonyour product oron itspackaging indicatesthat thisproductshould notbetreatedas household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the e...

Отзывы: