MI000692-E
ENGLISH - 2/4
DIMENSIONS
INSTALLATION
17,5 mm
100 mm
The Z110S and Z110D are designed for easy mounting on 35mm DIN rail.
Страница 1: ...tput Protection Standards Current 4 20 mA Minimum Volt Drop at 20mA 7V all loads up to 160ohm Maximum Volt Drop at 20mA 3 8V Load Resistance 0 02V 4 20 mA active max load resistance 500 ohm Temperature 0 50 C Humidity min 30 max 90 40 C non condensing Calibration Error 0 1 off f s 0 1 off f s 0 1 off f s Thermal Coefficient 0 02 off f s C Linearity error Load variation effect 100 mS to reach 90 of...
Страница 2: ...MI000692 E ENGLISH 2 4 DIMENSIONS INSTALLATION 17 5 mm 100 mm The Z110S and Z110D are designed for easy mounting on 35mm DIN rail ...
Страница 3: ...on furnaces CHANNEL 1 INPUT Z110S and Z110D CHANNEL 1 OUTPUT Z110S and Z110D 10 11 12 mA PASSIVE INPUT Connect the module in the current loop as shown The module is powered by the 4 to 20mA current loop Voltage Drop at 20mA 3 8V plus Load Volt drop 0 02 load resistance minimum 7V e g with load of 250ohm Volt Drop is 3 8V 0 02 250 8 80V ACTIVE OUTPUT The module generates a current in the output loo...
Страница 4: ...it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and humanhealth which couldotherwisebe causedbyinappropriatedisposalofthisproduct Therecycling of materials will help to conserve natural resources Fo...