background image

Universal input

Installation

Manual

Installation

Manual

Installation

Manual

Installation

Manual

UNIVERSAL CONVERTER

WITH ISOLATED BIPOLAR OUTPUT

UNIVERSAL CONVERTER

WITH ISOLATED BIPOLAR OUTPUT

Serie Z

Serie Z

Z109REG-BP

Z109REG-BP

EN

EN

MI003470-E

ENGLISH 1/8

SENECA

S

MI003470-E

MI003470-E

ENGLISH 4/8

ENGLISH 8/8

MI003470-E

MI003470-E

MI003470-E

MI003470-E

ENGLISH 3/8

ENGLISH 7/8

ENGLISH 5/8

ENGLISH 6/8

(1) Influence of wire resistances: 0.1 uV/

W

(2) Output zero if t < 250°C
(3) RTD type: P

00, P 500, P 1000, N 100

T

T

T

I

1

All the errors have to be calculated with reference to resistive value.
(4) Influence of wire resistances: 0.005 %/ , max 20

W

W

Errors related to max
measuring range

Accuracy

Thermal
stability

Linearity
error

EMI

TC input type: J, K, E, T, N

0.1%

0.01%/°K

0.2°C

<1% (1)

TC input type: R, S

0.1%

0.01%/°K

0.5°C

<1% (1)

TC input type: B

(2)

0.1%

0.01%/°K

1.5°C

<1% (1)

Cold junction compensation
(for all TC inputs type)

2°C tra 0°C e
50°C ambiente

/

/

/

Thermoresistance
input type (RTD)

(3)

0.1%

0.01%/°K

t>0°C 0.02%
t<0°C 0.05%

<1% (4)

Potentiometer or rheostat
input type

0.1%

0.01%/°K

0.1%

<1%

Voltage or current input type

0.1%

0.01%/°K

0.05%

<1% (1)

Standards

The module complies with the following standards:

EN61000-6-4

(electromagnetic emission,

industrial environment).

EN61000-6-2

(electromagnetic immunity,

industrial environment).

EN61010-1

(safety).

Isolations

1500 V

Potentiometer input:
One R = 330Ω resistance
parallel circuit is needed.
Potentiometer value must
be from1 kΩ to 100kΩ

Thermocouple input type:
J, K, R, S, T, B, E and N.
Input voltage for
Full scale < 150 mV

Passive current input (-20 – +20 mA).

The sensor supplies the current loop.

Use this connection if the input

current come from outside.

Active current input (-20 – +20 mA).
The module supplies the current loop.
Use this connection with 2 wire
measurement. The transducer is
powered by the module Z109REG-BP

.

Thermoresistance input type:
PT100, NI100, PT500 and PT1000.
The two-wire connection can also be
used for NTC and KTY

ENGLISH 2/8

MI003470-E

TECHNICAL SPECIFICATIONS

Universal Input

Sampling
frequency

Variable from 240 sps with 11 bit + sign resolution
to 15 sps with 15 bit + sign resolution (tipical values).

Filter

The input signal filter level can be enabled and configured: from
0.5 to 60 sec.

Response time

35 ms with 11 bit resolution, 140 ms with 16 bit resolution ( for
measures: voltage, current and potentiometer)

Voltage input mode

Bipolar from 75 mV to 20 V with 9 scales,
input impedance: 1 M

Max resolution 15 bit + sign.

W.

Current input mode

Bipolar up to 20 mA. Internal shunt 50

. Max resolution

.

W

~

m

1 A

Powered sensor loop: from sensor to module (passive module) or
from module to sensor(actvive module) by terminal 7
(Max 25 mA

a Max 20 V )

.

~

~

with short-circuit protection

Automatic input out of range detection.

thermoresistances
(RTD) input mode

RTD type: P

00, P 500, P 1000, N 100,

T

T

T

I

1

KTY81, NTC,

KTY84 -130/-150. Resistance measure 2, 3 or 4 wires and
resistance wire measure. Energising current: 0.56 mA.
Risoluzione 0.1 °C. Automatic burn-out detection.
For NTC resistance value < 25k .

W

NTC, KTY81 and KTY84 configurable only by software.

thermocouples (TC)
input mode

TC type: J, K, R, S, T, B, E, N. Input impedance: > 5 M

W.

Automatic burn-out’s detection. Resolution 2.5 V.

m

Potentiometer input
mode

Excitation voltage of 300mV. Potentiometer input value
from 500

to 100 k

(a R = 500

parallel circuit must be added).

W

W

W

Automatic input out of range detection.

Rheostat input

Input rheostat value: from 500

to Max 25 k

W

W

GENERAL SPECIFICATIONS

Ÿ

Universal input: voltage (mV ), current (mA ), thermocouples C,

~

~

T

RTD

thermoresistances

, potentiometer, rheostat, NTC.

Ÿ

Measurement and re-transmission on isolated analog bipolar output, with voltage output
or current.

Ÿ

DIP-switch for selecting: type of input, START-END, output mode (zero elevation,
scale inversion), output voltage type (mA or V ).

Ÿ

Removable terminals with section of 2.5 mm

2

Ÿ

Possibility of USB configuration.

Ÿ

Sensor powered by 2 / 3 wire technique is available: 20V

Max stabilised, 20mA Max

~

(terminal 7).

with short-circuit protection

Ÿ

3-point insulation: 1500V .

~

Ÿ

Front panel indicating: power on, off scale or setting error and alarm status.

Ÿ

Facility for programming the following through PC: START-END scale, additional input
types, square root extraction, filter, burn-out etc. (See:

www.seneca.it)

Contents:

- General specifications
- Technical specifications
- Installation rules
- Selection: input/ measuring scale
- Selection: output type
- Setting START and END at will
- Frontal LEDs indications’s
- Setting with a PC
- Electrical connections
- Default conditions
- Purchase order codes
- Module layout
- Decommissioning and disposal

This document is property of SENECA srl. Duplication and reprodution are forbidden, if not

authorized.

Contents of present documentation refers to products and technologies described in it. All technical data
contained in the document may be modified without notice. This document is subject to periodical revision.

Outputs

Channel numbers

1

Output type

Current: -20 – +20 mA, Maxium load resistance 500

W

Voltage: -10 – +10 V, minimum load resistance 1 k

W

Resolution

5 µA / 2.5 mV.

Environmental conditions

Temperature

-20 – +65°C

Humidity

30 – 90% a 40°C not condensing

Altitude

Up to 2000m a.s.l.

StorageTemperature

-20 – +85°C

Protection degree

IP20

Data Memory

EEPROM for all configuration data; storage time: 40 years.

Power supply

Voltage

10 – 40 V ;

19 - 28 V     50 – 60 Hz

~

~

Consumption

Max: 2W

Dimensions / Module box

Dimensions

L: 100 mm; H: 112 mm; W: 17,5 mm

Module box

PBT, black

Electrical connections

Removable

screw terminals

3-way

5 mm pitch

MicroUSB frontal plug

Power supply

Input

Output

1500V

SELECTION: INPUT / MEASURING SCALE

The type of input is selected by setting the SW1 DIP-Switches group at the side of the
module.
Each type of input is matched with a number of beginnings scale (START) and full
scale (END) selectables with the SW2 DIP-Switches group.
The frames above show the START or END values for every selected input.

SW1

INPUT TYPE

1 2 3 4

zzzz
yzzz
zyzz
yyzz
zzyz
yzyz
zyyz
yyyz

V

/ Rheostat

W

mA

NI100

PT100
PT500

PT1000

Tc J

SW1

INPUT TYPE

1 2 3 4

zzzy
yzzy
zyzy
yyzy
zzyy
yzyy
zyyy
yyyy

Tc K
Tc R
Tc S
Tc T
Tc B
Tc E
Tc N

Potentiometer

SW2

START

1 2 3

zzz
zzy
zyz
zyy
yzz
yzy
yyz
yyy

1
2
3
4
5
6
7
8

SW2

END

4 5 6

zzz
zzy
zyz
zyy
yzz
yzy
yyz
yyy

1
2
3
4
5
6
7
8

1 2 3 4 5 6 7 8

SW2

DIP -Switch in OFF position

zzzzzzzz

Start      End

SW2

DIP

Voltage

Resistance /

Rheostat

Current

Potentiometer

NI100 (RTD)

PT100 (RTD)

START

END

START

END

START

END

START

END

START

END

START

END

zzz

1

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

zzy

2

0 V

100 mV

0

W

1 k

W

0 mA

1 mA

0 %

40 %

-50°C

20°C

-200°C

50°C

zyz

3

400 mV 200 mV

0.5 k

W

2 k

W

1 mA

2 mA

10 %

50 %

-30°C

40°C

-100°C

100°C

zyy

4

1 V

500 mV

1 k

W

3 k

W

4 mA

3 mA

20 %

60 %

-20°C

50°C

-50°C

200°C

yzz

5

2 V

1 V

2 k

W

5 k

W

-1 mA

4 mA

30 %

70 %

0°C

80°C

0°C

300°C

yzy

6

-5 V

5 V

5 k

W

10 k

W

-5 mA

5 mA

40 %

80 %

20°C

100°C

50°C

400°C

yyz

7

-10 V

10 V

10 k

W

15 k

W

-10 mA

10 mA

50 %

90 %

30°C

150°C

100°C

500°C

yyy

8

-20 V

20 V

15 k

W

25 k

W

-20 mA

20 mA

60 %

100 %

50°C

200°C

200°C

600°C

SW2

DIP

PT500 (RTD)

PT1000 (RTD)

Thermocouple J

Thermocouple K Thermocouple R Thermocouple S

START

END

START

END

START

END

START

END

START

END

START

END

zzz

1

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

zzy

2

-200°C

0°C

-200°C

0°C

-200°C

100°C

-200°C

200°C

0°C

400°C

0°C

400°C

zyz

3

-100°C

50°C

-100°C

50°C

-100°C

200°C

-100°C

400°C

100°C

600°C

100°C

600°C

zyy

4

-50°C

100°C

-50°C

100°C

0°C

300°C

0°C

600°C

200°C

800°C

200°C

800°C

yzz

5

0°C

150°C

0°C

150°C

100°C

400°C

100°C

800°C

300°C

1000°C

300°C

1000°C

yzy

6

50°C

200°C

50°C

200°C

200°C

500°C

200°C

1000°C

400°C

1200°C

400°C

1200°C

yyz

7

100°C

300°C

100°C

300°C

300°C

800°C

300°C

1200°C

600°C

1400°C

600°C

1400°C

yyy

8

150°C

400°C

200°C

400°C

500°C

1000°C

500°C

1300°C

800°C

1750°C

800°C

1750°C

SW2

DIP

Thermocouple T

Thermocouple B

Thermocouple E Thermocouple N

START

END

START

END

START

END

START

END

zzz

1

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

zzy

2

-200°C

50°C

0°C

500°C

-200°C

50°C

-200°C

200°C

zyz

3

-100°C

100°C

500°C

600°C

-100°C

100°C

-100°C

400°C

zyy

4

-50°C

150°C

600°C

800°C

0°C

200°C

0°C

600°C

yzz

5

0°C

200°C

700°C

1000°C

100°C

300°C

100°C

800°C

yzy

6

50°C

250°C

800°C

1200°C

150°C

400°C

200°C

1000°C

yyz

7

100°C

300°C

1000°C 1500°C

200°C

600°C

300°C

1200°C

yyy

8

150°C

400°C

1200°C 1800°C

400°C

800°C

500°C

1300°C

Beware:

DIP-switches must be set
while the module is
powered down, otherwise,
the module may be
damaged.

(*) START or END
are set in memory with the PC or
with a programming push buttons.

SETTING START AND END AT WILL

The START and END push-buttons under the SW2 DIP-switch group allow to set the beginning and end
scale at will within the scale pre-set through the dip-switches.
To obtain this facility it is necessary to use a suitable signal generator, able to furnish the desired values of
beginning and end scale.
The procedure is following:

1. Set to SW1 the type of input desired, set to SW2 a START and END measurement which include
the required beginning and end values.
2. Power up the module.
3. Supply a calibrator or simulator of the signal you wish to measure and re-transmit.
4. Set the required START value on the calibrator (or other instrument).
5. Press the START push-button for at least 3 sec.
The green LED on the front panel flashes to indicate the value has been stored.
6. Set the required END value on the calibrator (or other instrument)
7. Press the END push-button for at least 3 sec.
The green LED on the front panel flashes to indicate the value has been stored.
8. Cut power to the module and set to OFF position the dip-switches of group SW2,
Like in

frame: START and END values row n°1 (*).

SW2 DIP

The module is now configured for the required start and end scale.
To reprogram it (e.g. for a different type of input) repeat the whole procedure.

SELECTION: OUTPUT TYPE

SW2 DIP-switches group numbers 7 and 8 enable you to set the output mode: voltage or current and
the output mode: normal or reversed.

SW2

OUTPUT TYPE

7

z
y

Current
Voltage

SW2

OUTPUT TYPE

8

z
y

Normal

Reversed

FRONTAL

LED INDICATIONS S

S

LED

STATE

MEANING OF LED

S

PWR Green

On

Power supply presence

PWR Green

Flashing (freq: 1 Flash./sec)

Out of range, Burn Out

PWR Green

Flashing (freq

»

2 Flash./sec)

DIP-Switch setting Error’s

ALARM Yellow

On

Internal fault

PURCHASE ORDER CODE

Order code

Description

Z109REG-BP

Bipolar universal converter with galvanic separation

KIT-USB

USB cable and configuration software

CAVO-USB-A-MICRO-B

USB / microUSB cable

DEFAULT CONDITIONS

Input type / Start – End range

Voltage / -10 V – +10 V

Input filter (acquired signal)

Disabled

Output type / Start – End range

Voltage / -10 V – +10 V

Reiection at mains frequency /
Sampling time

Reiection = 50Hz /
Sampling time = 20ms

Cold junction compensation ( for RTc input)

Disabled

Variations of standard parameters are possible by software (see www.seneca.it).
For more information about a list of all register and their function consult the USER manual.

DECOMMISSIONING AND DISPOSAL

Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European
countries with separate collections programs). This symbol, found on your product or on its packaging, indicates
that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be
handed over to an applicable collection point for the recycling of electrical & electronic equipment. By ensuring this
product is disposed of correctly, you will help prevent potential negative consequences to the environment and
human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of
materials will help to conserve natural resources. For more detailed information about the recycling of the product,
please contact your local city office, waste disposal service of the retail store where you purchased this product.

MODULE LAYOUT

MODULE DIMENSIONS

FRONT PANEL

Z109REG-BP

PWR/ERR

x

x

USB

ALARM

Y

SETTING WITH A PC

By using a PC and downloadable softwares from

, it is possible to set other normally fixed

www.seneca.it

parameters in addition to start and end scale:

—

Additional input types.

—

Digital filter (normally disabled).

—

Square root extraction (normally disabled).

—

Negative burn-out (normally positive).

—

Start and end scale of the analog output.

—

Value of the analog output in case of error.

—

Rejection programmable for 50 or 60 Hz mains frequency (normally set to 50 Hz).

—

Sampling frequency/resolution (normally set to 15 sps/16 bit).

—

3 or 4 wires measure for thermal resistance (normally set to 3 wires).

—

The instructions for setting and USB cable are supplied as a KIT available on request.

E

C

AL CONNECTIONS

LE TRIC

Power supply

The supply voltage must be between 10 to 40 V

(Any polarity) or between 19 e 28 V .

~

~

These upper limits must not be exceeded to avoid serious damage to the module.

any failure of the module using

It’s necessary to protect the power supply source against
appropriately sized fuse (Max = 2.5A).

2

3

19 – 28 V

~

50 – 60 Hz
10 – 40 V

~

2 W Max

10

12

9

POT

8

R

mV/TC

10

12

+

10

11

7

11

10

9

+

Voltage input (-20 – +20 V )

~

Full scale > 150 mV

10

9

8

12

4-wire

12
10

9

8

RTD

3-wire

12
10

9

8

RTD

2-wire

12
10

9

8

RTD

Rheostat input:
values from 500 Ω to
25 kΩ are needed

Voltage output

5

4

V

+

Current output

5

4

mA

+

Output

1

12 mm

17,5 mm

100,0 mm

INSTALLATION RULES

The module is designed to be installed, in vertical position, on DIN 46277 rail. For the best
module performance and long life, avoid to place cables raceways and other objects that
could obstruct ventilation slits.
Never install the modules near heat sources. We suggest to install the module in the bottom of
the control panel.

Errors

Accuracy

Thermal stability

Voltage output

10 mV

0.5mV/K

Current output

20 µA

1µA/K

ADDITIONAL NOTES

:

One max 2.5A fuse must be installed near the module.

Отзывы: