background image

MI00205-7-EN

INSTALLATION MANUAL

1/4

INSTALLATION MANUAL

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available via QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to 

electrostatic discharges. Take appropriate measures during any operation.

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at risk.

The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

DOCUMENTATION

Z-D-IN

Z-D-IN

Содержание Z-D-IN

Страница 1: ...ke appropriate measures during any operation PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user s safety at risk The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment The warranty shall become null and void in the event of improper use or tampering with the mo...

Страница 2: ...T PANEL TECHNICAL SPECIFICATIONS CERTIFICATIONS https www seneca it products z d in doc CE_declaration INSULATION POWER SUPPLY Voltage 10 40Vdc 19 28Vac 50 60Hz Absorption Typical 1 5W 24Vdc Max 2 5W USE Use in environments with pollution degree 2 The power supply unit must be class 2 ENVIRONMENTAL CONDITIONS Temperature 10 65 C Humidity 30 90 at 40 C non condensing Altitude Up to 2 000 m above se...

Страница 3: ...on length Module Module Module Module Module 3 Bus length Ld derivation length ModBUS CONNECTION RULES 1 Install the modules in the DIN rail 120 max 2 Connect the remote modules using cables of an appropriate length The following table shows cable length data Bus length maximum length of the Modbus network according to the Baud Rate This is the length of the cables that connect the two farthest mo...

Страница 4: ...ine with a value suitable to what the situation requires ModBus RS485 Connection for RS485 communication using the MODBUS master system as an alternative to the Z PC DINx bus N B The indication of the RS485 connection polarity is not standardised and in some devices may be inverted INPUTS 1 11 12 7 8 9 10 1 2 3 4 5 Z D IN 1 16V 1 11 12 7 8 9 10 1 11 12 7 8 9 10 PNP NPN 1 2 3 4 5 1 2 3 4 5 R 1k5 1k...

Отзывы: