background image

MI00360-2-EN

INSTALLATION MANUAL

1/4

INSTALLATION MANUAL

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available via QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to 

electrostatic discharges. Take appropriate measures during any operation.

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at risk.

The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

DOCUMENTATION

Z-4AI

Z-4AI

Содержание Z-4AI

Страница 1: ...ake appropriate measures during any operation PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user s safety at risk The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment The warranty shall become null and void in the event of improper use or tampering with the m...

Страница 2: ...POWER SUPPLY Voltage 10 40Vdc 19 28Vac 50 60Hz Absorption Typical 0 5W 24Vdc Max 3 5W MODULE LAYOUT Dimensions LxHxD 17 5 x 102 5 x 111 mm Weight 110 g Enclosure PA6 black 17 5 mm 111 mm 102 5 mm LED STATUS LED meaning PWR Green ON The device is powered correctly FAIL yellow Flashing Anomaly or fault RX Red Flashing Receipt of packet completed RX Red ON Anomaly Check connection TX Red Flashing Tra...

Страница 3: ... 1 to 4 VOLTAGE 10 Vdc Numerical representation of the input measurement 10000 mV Sampling time 120 ms 1200 m 2 m 2 1 4 5 Ld Diagram 1 Bus length Derivation length Module Module Module Module Module 3 Bus length Ld derivation length ModBUS CONNECTION RULES 1 Install the modules in the DIN rail 120 max 2 Connect the remote modules using cables of an appropriate length The following table shows cabl...

Страница 4: ...overload a safety fuse with a 2 5A max permissible value must be installed in the power supply line GND B A 4 5 6 ModBus RS485 ConnectionforRS485communicationusingtheMODBUSmastersystemasanalternative to the Z PC DINx bus N B The indication of the RS485 connection polarity is not standardised and in some devices may be inverted INPUTS A Voltage input with sensor supply from the MODULE 13 Vdc B Volt...

Отзывы: