4/4
TECHNICAL SPECIFICATIONS
STANDARDS
EN61000-6-4
Electromagnetic emissions, industrial environment.
EN61000-6-2
Electromagnetic immunity, industrial environment.
EN61010-1
Safety
INSULATION
ENVIRONMENTAL
CONDITIONS
Temperature
: -20
÷
+ 65°C
Humidity
: 10%
÷
90% non condensing.
Altitude:
up to 2000 m above sea level
Storage temperature:
-40
÷
+ 85°
Protection degree:
IP20.
ASSEMBLY
IEC EN60715, 35mm DIN rail through terminals.
CONNECTIONS
5-way removable screw terminals, pitch 5 mm
POWER SUPPLY
Through PC USB port.
SERIAL
COMMUNICATION
RS232 (DB9-M), RS485 (5 poles), TTL (RJ10), USB 1.0, 1.1, 2.0
BAUDRATE
1200 bps,115200 bps.
WARNING
the maximum working voltage between any termi
-
nal and ground must be less than 50Vac/75Vdc
Power
Supply
Input
Output
1500 V
~
RS485
USB
In/Out
RS232
TTL
INSTALLATION REGULATIONS
As regards the S117P1 instrument, there are no particular precautions to follow, except that of using a shielded
cable for the RS232 and RS485 lines for long connections or connections in noisy environments.
TERMINAL POSITION AND DESCRIPTION
The drawing below shows the functions of the removable screw connector on the side of the S117P1:
PIN INDEX
DESCRIPTION
1
Power Supply Ground
2
Max: + 12Vdc @ 100 mA
3
A
4
B
5
Modbus Ground
CONTACT INFORMATION
Technical support
Product information
This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The con-
tent of this document corresponds to the described products and technologies. Stated data may be modified or
supplemented for technical and/or sales purposes.