background image

INSTALLATION MANUAL

MyBoat

Real time remote control and alarm management

device for boats

SENECA s.r.l. 

Via Austria, 26 – 35127 – PADOVA – ITALY 

Tel.  +39.049.8705355 - 8705359  -  Fax +39.049.8706287

For manuals in other languages and the configuration software, visit www.seneca.it/myboat

EN

MI00498-2-EN

1/8

Содержание MyBoat

Страница 1: ...ontrol and alarm management device for boats SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and the configuration software visit www seneca it myboat EN MI00498 2 EN 1 8 ...

Страница 2: ... prohibited Electrical and electronic waste disposal applicable in the European Union and other countries with recycling The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste The module must be repaired and damaged parts replaced by the Manufacturer The product is sensitive to electrostatic disc...

Страница 3: ...sh Push for mini SIM 15 x 25 mm GSM Quad band 850 900 1800 1900 MHz MMCX CONNECTOR External GPS antenna connector optional ENVIRONMENTALCONDITIONS Temperature Humidity Storage temperature Protection rating Seneca recommends use at 0 to 45 C for correct operation With the power supply present 20 55 C With use of the battery when discharged 20 45 C Charging is possible in the range 0 45 C 30 90 non ...

Страница 4: ...ia the micro USB port with a standard cable Power supply through the USB jack is not suitable for fixed installations or configurations where relays and or digital inputs are used PWR SCR ANTENNA ANTENNA micro USB AUTO POWER OFF If the display shows LOW BAT it means that the internal battery is low after 60 seconds the device switches off automatically To restore the battery charge to an appropria...

Страница 5: ...he MyBoat control unit has a terminal block inside its enclosure To access the internal terminal block of the device unscrew the screw at the centre of the black cover positioned at the bottom of the enclosure and lift up In the side figure the cover has been removed IMPORTANT With the relay card mobile wiring of cables connected to terminals is not permitted To make the cables from the terminals ...

Страница 6: ... a rigid cable A press with a screwdriver B insert the cable A press with a screwdriver B extract the cable PUSH WIRE TERMINAL BLOCK 1 2 3 4 5 6 7 8 9 10 11 12 13 timed AUX 1 Common to the two relays Not timed AUX 2 normally closed DIN 1 AUX 12 Vdc GND service battery sensor AIN 1 0 V 0 10 V 100 AIN 2 GND Sensor input NTC Power Power normally closed DIN 2 normally closed DIN 3 normally closed DIN ...

Страница 7: ...ain heavy metals or material harmful to the environment and health Since they also contain important elements such as iron zinc manganese and nickel they can be recycled We recommend using batteries of the same type inside a device the use of batteries of different types could cause liquid leakage or battery breakage or damage the device in use Always replace the battery or batteries of the device...

Страница 8: ... battery monitoring MYBOAT S5 Replacement sensor for battery monitoring MYBOAT S6 Replacement sensor for bilge monitoring MYBOAT S7 Replacement sensor for access control MYBOAT S8 Replacement sensor for access control CONTACT INFORMATION Technical support support seneca it Product information sales seneca it This document is the property of SENECA srl Copies and reproduction are prohibited unless ...

Отзывы: