Sencore VB7810 Скачать руководство пользователя страница 2

Quick Start Guide

 

VB7810

 

 

 

 

 

 
Form 8155 

Version 5.3 - June 2017 

Page 2   

 

Figure 2: Setting the IP address manually in Windows 

Connecting to the VB7810 Using SSH 

In order to manage the server’s IP address settings remotely or via the network 
connection, an SSH session must be established. Any regular SSH client can be 
used. One popular client, the free application PuTTY, can be downloaded from 

http://www.chiark.greenend.org.uk/~sgtatham/putty. 

Use the VB7810 default Control port IP address 10.0.20.105 (or another address 
if it has been changed) as the Host Name and click the OPEN button. The default 
Linux login for Sencore VideoBRIDGE servers is 

root

 for the user and 

mpeg101

 

for the password. Once you are logged in, use the nmtui

 

tool to edit the network 

connections.  

Connecting Monitor and Keyboard to the VB7810 

It is also possible to configure the network settings of the VB7810 using a 
monitor and keyboard connected directly to the server. Once the VB7810 server  

Figure 3: SSH Connection with PuTTY

 

boots, login to Linux. The default Linux login for Sencore VideoBRIDGE servers 
is 

root

 for the user and 

mpeg101

 for the password. Once you are logged in, use 

the nmtui

 

tool to edit the network connections. 

Editing Network Connection Settings Using nmtui 

The network settings of the VB7810 can be edited using various methods 
applicable to Linux servers. Sencore recommends the use of the graphical tool 
nmtui. To load the nmtui tool, type 

nmtui

 in the command line and press ENTER. 

Once the nmtui tool is loaded, use it to edit a connection.  There should be two 
connections for the VB7810. The one preset to 10.0.20.105 is the control port 
and the other is typically for the MPEG over IP input. It is also possible to receive 
MPEG over IP streams using the Control port. Edit the network settings so that 
they are appropriate for your network. Then save and quit nmtui and reboot the 
server using the 

reboot

 command to apply the new settings. 

Once the server reboots, the web user interface can be accessed using the IP 
address that was set for the control port. All further configuration takes place 