background image

 

14 

Recovery 

Yes/NO 

   

Reboot 

Yes/NO 

   

 

Press 

OK

 to apply, press 

MENU

 to back to upper layer, press 

direction arrows

 to move to other 

items. 

3.2 Operating the WEB Interface 

3.2.1 Access Interface 

 

PC Web-GUI 

NB100U  can be accessed and configured via web GUI.  The accessing instruction is as the 
followings: 

1.

 

Connect the “RJ45” port of the NB100U to the management PC/server directly or via a 

network switch. 

2.

 

The 

NB100U  default IP address is 192.168.1.106

.  Please  modify the  management 

server’s IP address or NB100U IP address to be in the same IP segment. To ensure that 

the equipment is smoothly connected to the network.   

3.

 

Open any web browser (e.g. Mozilla v30 or above, IE8.0 or above, safari, chrome v42 or 

above  and etc.), input the equipment’s IP address in format: 

http://xxx.xxx.xxx.xxx

 

(xxx.xxx.xxx.xxx refers to NB100U’s IP address) and press ENTER button to confirm. The 

browser will attempt to connect to the device. If succeed, a login page will appear. 

(see 

PIC-3.2.1)

 

Содержание StreamCast NB100U

Страница 1: ...NB100U Portable Encoder User s Manual V1 00 N ...

Страница 2: ...introduction to product installation product characteristics and product settings etc It is highly suggested users to go through this document before actually operating the device Intended Readers This manual is suggested to be studied by the following readers Technical Service Engineer Maintenance Engineer Test Engineer Sales Engineer ...

Страница 3: ... that accompanies this product This symbol indicates important operating or maintenance instructions Please use the cable of good quality and make sure the connector is in good condition Please do not use the power supply that doesn t match the requirement Please do not open the machine cover Specifications and functions may be changed for improvement without notice in advance ...

Страница 4: ...g by implication estoppel or otherwise any license or right under any copyright or patent whether or not the use of any information in this document employs an invention claimed in any existing or later issued patent Copyright Information in this publication is subject to change without notice No part of this publication may be reproduced or transmitted in any form by photocopy microfilm xerograph...

Страница 5: ...ly the instructions that are included in the operating instructions Refer all servicing and installation to qualified service personnel only Electric shock can cause personal injury or even death Avoid direct contact with dangerous voltages at all times The protective ground connection where provided is essential to safe operation and must be verified before connecting the power supply Know the fo...

Страница 6: ...int where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms or when unused for long periods of ti...

Страница 7: ...xpose this apparatus to rain or moisture The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus Revision History Date Version Description Author 11 22 2017 1 00 First Draft Zita ...

Страница 8: ...Equipment Wiring and Connection 11 2 3 1 Power Connection 11 2 3 2 DC Power Connection 11 2 3 3 Connection Setup for Web Management 11 2 3 4 Connection Setup for HDMI CVBS SDI signal input 12 3 CHAPTER3 OPERATION GUIDE 12 3 1 Operating the Front Panel Interface 12 3 1 1 Powering Up and Initialization 12 3 1 2Front Panel Menu Structure 13 3 2 Operating the WEB Interface 14 3 2 1 Access Interface 14...

Страница 9: ...8 3 2 2 Main Interface 15 3 2 3 Live Mode 16 3 2 4 Playback mode 24 3 2 5 Recording Mode 27 3 2 6 System 29 ...

Страница 10: ... supports Closed Caption 1 2 Architecture Front Panel 3 2 1 4 1 Power status indicator This LED light is turned on when the StreamCast is power on Signal Lock status indicator This LED light is turns to green when a channel is locked Otherwise the light turns to red 2 Display screen This LCD screen can show the management IP address work mode Input stream standard output protocol running status an...

Страница 11: ... port 2 RF OUT port 3 RJ45 management connection port 4 DC DC Power connection 2 CHAPTER2 INSTALLATION 2 1 Installation Procedure Preparation before Installation Setup Connection signals wiring Parameters Configuration System Debug Finish ...

Страница 12: ... 3 1 Power Connection Use the proper power connections is vital to the safe operation of the portable encoder Only use the supplied power connector or one with equal specifications Never use the power connector whose specification is different from we supplied This could cause damage to the Portable Encoder 2 3 2 DC Power Connection The DC power supply option allows the NB100U to be powered by a s...

Страница 13: ...en is lighted up and display information as following There will be 3 seconds leaving for you to choose which mode you ll start After 3 seconds the portable encoder will start the last mode automatically If you press OK button in the front panel and display information as following Press arrow Up or Down in the front panel to choose start mode The initialization takes about 30 seconds to complete ...

Страница 14: ... Mode live Input Auto HDMI YPbPr AV SDI Output UDP RTP RTSP HLS Live RTMP IP x x x x Port xxxxx Playback Mode Sequence Clrole Single Clrole List Clrole Random IP x x x x Port xxxxx Recorded Recording Input Auto HDMI YPbPr AV SDI System Network Mode DHCP Enable Disable DNS Static Dynamic Host IP Gateway Mask DNS x x x x AP Wi Fi ON OFF Version SW FW HW version ...

Страница 15: ...ia a network switch 2 The NB100U default IP address is 192 168 1 106 Please modify the management server s IP address or NB100U IP address to be in the same IP segment To ensure that the equipment is smoothly connected to the network 3 Open any web browser e g Mozilla v30 or above IE8 0 or above safari chrome v42 or above and etc input the equipment s IP address in format http xxx xxx xxx xxx xxx ...

Страница 16: ... Please refer to 3 3 6 System Wi Fi Hotspot 3 2 2 Main Interface NB100U provides 3 working modes Live Playback and Recording Click to enter desire working mode PIC 3 2 2 Live Mode to encode a live channel via HDMI SDI CVBS input and IP output Playback Mode to play the recorded TS from external USB disk Recording Mode to record the encoded TS and store it to the external USB disk ...

Страница 17: ...coding as well as the broadcasting mode and parameters Basic Setting Pic 3 2 3 1 This interface provides the main parameters of encoding and broadcasting Please check and set the parameter according to the following items Input HDMI SDI YPbPr AV Auto source can be selected ...

Страница 18: ...ou can configure the IP streaming output address UDP Setting User can set IP Port parameter Pic 3 2 3 2 RTSP Setting User can view RTSP URL Ethernet RTSP URL Wireless parameter Pic 3 2 3 3 HLS Setting User can view HLS URL Ethernet HLS URL Wireless parameter Pic 3 2 3 4 ...

Страница 19: ...er can set RTP IP Port parameter Pic 3 2 3 5 RTMP Setting User can set RTMP FMS URL Stream Port Encryt parameter Pic 3 2 3 6 Modulation Setting QAM Modulation is custom made feature with additional hardware Pic 3 2 3 7 ...

Страница 20: ...Symbol Rate is fixed in 5057 in 64QAM Mode and 5360 in 256QAM Mode KBaud Pic 3 2 2 1 7 QAM Mode support 64 256QAM output Pic 3 2 3 8 The output power Level Range is from 90 to 116 dBu Pic 3 2 3 9 The Interleave mode can be set as these parameters below ...

Страница 21: ...lease click the Advance Settings chars in blue It will reflect to the new page to set the detailed parameters for Live Mode It contains three parts of configuration Stream info Video info and Audio info Dolby D St Creator Pic 3 2 3 11 Stream info In this page you can configure the Output Standard Program Number Stream ID PMT PID PCR PID and etc Pic 3 2 3 11 Output Standard MPEG DVB ATSC ...

Страница 22: ... Source base on the source you selected in basic setting page Video PID ranging from 32 8190 Video Encoding Mode H 264 MPEG2 Video Resolution Auto User can choose certain output resolution Resolution Supported HD 1920 x 1080 24p 25p 30p 50i 60i 1280 x 720 50p 60p 25p 30p SD 720 x 576 50i 720 x 480 60i Aspect Ratio Auto 16x9_Letter Box 16x9_Cutoff 4x3_Pillar Box 4x3_Cutoff Video Bitrate Mode CBR VB...

Страница 23: ...reset output signal is of the allowed ones see mapping table below the preset will be remained otherwise the output resolution will changed to Auto automatically input signal preset output signal 1920x1080_30p 1920x1080_30p 1280x720_30p 720x480_60i 1920x1080_60i 1920x1080_30p 1920x1080_60i 1280x720_30p 720x480_60i 1920x1080_24p 1920x1080_24p 1920x1080_50i 1920x1080_25p 1920x1080_50i 1280x720_25p 7...

Страница 24: ... AAC LC MPEG4 AAC LC Audio Bitrate 128K 160K 192K 224K 256K 320K 384K 448K AC3 AC mode 1 1 L R 1 0 C 2 0 L R Audio Volume 12 12 Audio Sampling Rate 48K is fixed output audio sampling rate Click Apply button to make the new configuration into effect when finishing the setting Click Start icon on the left bottom to make the encoding into effect Note When you apply the new configuration the status sh...

Страница 25: ...nd updates the real time status of encoding and streaming 3 2 4 Playback mode Basic Setting 1 Plug one USB disk to USB port on the front panel of the NB100U to play the TS from the disk 2 Click the Playback icon to get the playback page which will list all the available TS from the USB disk 3 Click the required TS to play the TS ...

Страница 26: ...ry of the last USB disk If there is no disk connected to add new Play list The default play list is named default to delete the existing Play list to modify the play list name to change the play mode including single cycle listing loop random order playback to add new TS to the play list ...

Страница 27: ...eaming Port The destination IP port for IP streaming Daily play plan To set the play plan Pic 3 2 4 3 In Modulation mode Pic 3 2 4 3 you can configure Frequency Symbol Rate Mode Level Interleave mode The setting parameter range is same as Modulation mode of Live mode Playback Status This page displays the status of Playback ...

Страница 28: ...e Status icon to reflect to the Status page Pic 3 2 5 1 Note If the USB disk is not connected or the there is not enough space on the disk it is not able to start the recording The minimum available free space is 10MB The NB100U will overwrite the first file it created when the free space is not enough all those files which are not created by NB100U will not be affected For Recording mode there ar...

Страница 29: ... Pic 3 2 5 3 Advance setting For advance setting please refer to 3 2 3 Live Encoding Advance setting Recording Status This page offers the status of the recording and the storage of the connected USB disk Pic 3 2 5 4 ...

Страница 30: ... and Contact us these items Pic 3 2 6 1 Pic 3 2 6 1 Network Status This page shows status of network related info Pic 3 2 6 2 Ethernet to set up equipment management access IP address Subnet Mask Gateway and etc Pic3 2 6 3 The NB100U can be configured to use DHCP to obtain an IP address Subnet Mask Gateway To obtain an IP address may require up to one minute ...

Страница 31: ...Fi Hotspot which enable PC Hand phone or Tablet to log in via wireless connection to the device Pic 3 2 6 4 Wi Fi Enable NB100U Wi Fi function to connect to a wireless LAN Pic 3 2 6 5 Note Wi Fi hotspot and Wi Fi reception have the same range When it is used as a ...

Страница 32: ...ternet time Pic 3 2 6 7 Upgrade to upgrade new version software by select a file and click the Arrow button It will take several minutes to finish the upgrading and after that after upgrading please reboot the unit Pic 3 2 3 8 Pic 3 2 6 8 Development to export clear the logs check the debug info export configuration export upgrade license view system information and etc Pic 3 2 6 9 ...

Страница 33: ... Debug User can check the debug info which is usually used for R D Pic 3 2 6 11 Configuration User can export configuration including system and service configuration in this tab Pic 3 2 6 12 License User can export upgrade license please do reboot to active the license ...

Страница 34: ...33 Pic 3 2 6 13 System information User can check system info in this tab Pic 3 2 6 14 Contact us Pic 3 2 6 15 ...

Отзывы: