MRD 6000
– User Manual
Page 14 (112)
For example, if the MRD 6000 has a Primary Video output format set to 3180x2160p 50
fps, SDI port 1B will output HD-SDI at 1080p 50 fps.
1.5 Cooling
The MRD 6000 is cooled via forced induction through the front of the unit and exhausted
through the vents in the rear of the chassis. The MRD 6000 is equipped with a temperature
controlled status indicator. If the temperature inside the unit exceeds 60
°C the red “Error”
text will illuminate on the front panel and a description of the error will
appear in the “Error
List.”
1.6 Rack Information
The MRD 6000
is intended to be mounted in a standard 19” rack. It occupies 1RU of rack
space and the connections are all on the rear of the unit.