Sencor SAC MT9030C Скачать руководство пользователя страница 12

- 8 -

Revision 12/2021

 Copyright © 2021, Fast ČR, a.s.

•  Prior to using this appliance, please read the user’s manual 

thoroughly, even in cases, when one has already familiarised 
themselves with previous use of similar types of appliances. Only use 
the appliance in the manner described in this user’s manual. Keep 
this user’s manual in a safe place where it can be easily retrieved for 
future use. 

•  We recommend saving the original cardboard box, packaging 

material, purchase receipt and responsibility statement of the vendor 
or warranty card for at least the duration of the legal liability for 
unsatisfactory performance or quality. In the event of transportation, 
we recommend that you pack the appliance in the original box from 
the manufacturer.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

DESCRIPTION OF THE APPLIANCE
A1 

Air outlet

A2 

Control panel

A3 

Handles (located along both 
sides)

A4 

Travel wheels

A5 

Air outlet

A6 

Power cord

A7 

Top air inlet

A8 

Top drain outlet

A9 

Bottom air inlet

A10 

Removable pre-filter

A11 

Condensate drain hole

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

DESCRIPTION OF ACCESSORIES
B1 

Flexible air exhaust hose

B2 

Window outlet

B3 

End piece

B4 

Remote control

B5 

Drain hose

B6 

Textile window gasket seal 
(not shown)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

DESCRIPTION OF THE CONTROL PANEL
C2 

Cooling mode indicator

C3 

Dehumidification mode 
indicator

C4 

Fan mode indicator

C5 

Timer indicator

C6 

Display

C7 

Fan speed indicators (High, 
Medium, Low, Auto)

Wi-Fi indicator light

C8 

On/Off POWER button

C9 

FAN button for setting the fan 
speed

C10 

– button

C11 

+ button

C12 

TIMER button for setting the 
timer

C13 

MODE button for selecting an 
operating mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

REMOTE CONTROL
D1 

Display

D2 

On/Off button

D3 

MODE button for selecting an 
operating mode

D4 

TIMER button for setting the 
timer

D5 

SLEEP button

D6 

SWING button

D7 

 button

D8 

 button

D9 

FAN button for setting the fan 
speed

D10 

°C / °F button for changing 
the temperature units

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

INSTALLATION
Installation location for the portable air conditioner

•  Locate the portable air conditioner on an even, dry and stable surface 

and within reach of a grounded power socket.

•  For easier handling, the portable air conditioner is equipped with travel 

wheels 

A4

. Do not use the travel wheels 

A4

 when you need to move 

the air conditioner over carpets or similar surfaces. Avoid riding over 
objects.

•  To achieve optimal efficiency, maintain a distance of at least 45 cm 

from the wall or other obstacles.

•  To ensure sufficient efficiency of the portable air conditioner, keep all 

windows and doors closed and blinds and drapes drawn.

•  Make sure that there is no heat source located in the room. Do not 

locate the portable air conditioner in a room with high humidity, e.g. 
laundry.

Note: 

Do not use the portable air conditioner to cool a room where 
computer servers, etc. are located.
Installation, adjustment, maintenance and repairs must only be 
performed by a qualified person.

Installation of flexible hose on to the portable air conditioner

•  The flexible hose 

B1

 must be connected to the portable air conditioner 

and installed into a window in accordance with the operating modes 
that you wish to set. Install the flexible hose 

B1

 when you wish to 

select the operating modes: cooling, dehumidification or automatic 
mode. It is not necessary to install the flexible hose 

B1

 when you wish 

to select the fan mode.

•  Extend the flexible hose 

B1

 to the required length. Put the end piece 

B3

 on to the end of the flexible hose 

B1

. Insert it into the air inlet 

A5

 

and turn it to the right to secure the hose 

B1

 in place.

•  Put the window outlet 

B2

 on to the end of the flexible hose 

B1

.

Installing the flexible hose using the textile gasket seal

•  The textile gasket seal 

B7

 is suitable for tilt-open, sash and roof 

windows. The textile gasket seal 

B7

 is fitted with a Velcro zip tape to 

make its installation in the window easier. Open the window and into 
the created crevice install the textile gasket seal 

B7

. We recommend 

that you thoroughly degrease the location (frame and sash) where 
you will be attaching the textile gasket seal 

B7

 using an appropriate 

cleaning agent. Remove the protective paper strip and stick the tape 
on to the window frame. Never stick it on to the inner surface of the 
frame, otherwise you will not be able to close the window. Then stick 
on the second part of the textile gasket seal 

B7

 on the inner or outer 

part of the window sash. Check that you can close the window.

•  In order to be able to insert he flexible hose 

B1

, the gasket seal is fitted 

with an integrated zip. Open the zip in such a location that will enable 
you to easily insert the flexible hose 

B1

.

•  It is not necessary to remove the textile gasket seal 

B7

 from the 

window when not using the portable air conditioner. The window can 
be closed even with the gasket seal installed.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

CONTROLS OF THE PORTABLE AIR CONDITIONER
A. CONTROL PANEL

•  Insert the power plug into a power socket. Now the portable air 

conditioner sets itself to the stand-by mode.

Turning the portable air conditioner on and off

•  To turn on the portable air conditioner, press button 

POWER C8

. Press 

it again to turn the portable air conditioner off.

Note: 

Never turn off the portable air conditioner by pulling the power 
cord out of the power socket. Turn off the portable air conditioner 
using button 

POWER C8

, wait a few minutes and then pull out 

the power cord.

EN Portable Air Conditioner Wi-Fi

User's manual

Содержание SAC MT9030C

Страница 1: ...EN PORTABLE AIR CONDITIONER WI FI Translation of the original manual SAC MT9030C SAC MT9031C...

Страница 2: ...SAC MT9030C SAC MT9031C...

Страница 3: ...A 1 2 3 4 5 6 8 9 7 10 11 B 1 2 3 4 5...

Страница 4: ...C 2 3 4 5 6 W 7 8 9 10 11 12 13 D 1 4 2 7 5 6 3 8 9 10 E...

Страница 5: ...must be adhered to Incorrect use as a result of not adhering to instructions may cause death injuries or damage This appliance may be used by children 8 years of age and older and by persons with phy...

Страница 6: ...e g running gas appliance or where there are not sources of ignition e g running electrical heating element Before connecting the appliance to a power socket check that the rated voltage on its rating...

Страница 7: ...that the appliance is correctly assembled according to the instructions in this user s manual Do not touch the appliance with wet or damp hands This applies especially when it is connected to a power...

Страница 8: ...check that all the condensate has been drained After transporting it wait at least 1 hour before using the appliance Do not use the appliance if it is not working correctly if it has been damaged or h...

Страница 9: ...r its power supply DO NOT CONNECT the unit to a power socket to which other electrical appliances are already connected The incorrect selection of an electrical power supply may result in a fire or in...

Страница 10: ...Warning Fire hazard SPECIFIC INFORMATION FOR APPLIANCES USING REFRIGERANT GAS R290 Carefully study any warnings CAUTION For defrosting and cleaning do not use any other tools than those recommended by...

Страница 11: ...ored in such a way as to prevent mechanical failure Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organisation that ensures...

Страница 12: ...le air conditioner in a room with high humidity e g laundry Note Do not use the portable air conditioner to cool a room where computer servers etc are located Installation adjustment maintenance and r...

Страница 13: ...tomatically If button TIMER C12 or POWER C8 are pressed after the automatic start is set then this setting will automatically be cancelled 2 Automatic shut off function When the portable air condition...

Страница 14: ...ours and one hour intervals until 24 hours Press button D4 once to confirm the setting The set time will appear on the display D1 and symbol will remain lit Once the set time elapses the portable air...

Страница 15: ...ioner according to the instructions contained in the preceding part of this user s manual Installation TROUBLESHOOTING Error messages Shown on the display Meaning Solution Low temperature The portable...

Страница 16: ...ced in the event that it is used outside the above described operating temperature range We reserve the right to change text and technical specifications INSTRUCTIONS AND INFORMATION REGARDING THE DIS...

Страница 17: ...FAST R a s U Sanitasu 1621 CZ 251 01 any www sencor eu...

Отзывы: