2012 Sencon Incorporated
Page 7
BCM500/387 Bodymaker System
387 Sensor Interconnection
Make sure to seat fully and tighten the
cable connector on the 11H-387 sensor.
Also install and clamp the hydraulic tubing
over the fitting. Otherwise, liquid may
infiltrate the connector and degrade
performance.
Note:
Consult the factory for Sencon
287 style sensor interconnection.
DC Signal Inputs
Configure the input signals as shown in the diagram below. Settings are made with minijumpers accessible
under the top cover of the unit. Remove the top cover by inserting a flat screwdriver blade in the slot shown
and rotating the blade to `pop' the cover off. This operation
MUST
be done with power off to avoid damaging
the unit.
Note:
Alternative input setups are possible. Consult the factory for details.