8-ENG

D22235

Break-In Procedures

This procedure is only required the first time the air
compressor is put into service.

1. Set the pressure switch OFF/AUTO lever to the "OFF"

position.

2. Plug the power cord into the correct branch circuit

receptacle.

3. Turn the regulator clockwise, opening it fully, to

prevent air pressure build-up in the tank.

4. Move the OFF/AUTO lever to "AUTO". The compres-

sor will start.

5. Run the compressor for 15 minutes. Make sure the

regulator is open and there is no tank pressure build-
up.

6. After 15 minutes, close the regulator by turning it

counterclockwise. The air tank will fill to cut-out
pressure and then the motor will stop.

Refer to Operating Procedures.

RISK OF ELECTRICAL SHOCK. IF REPAIR-
ING OR REPLACING CORD OR PLUG, THE
GROUNDING WIRE MUST BE KEPT SEPA-
RATE FROM THE CURRENT-CARRYING
WIRES. NEVER CONNECT THE GROUNDING
WIRE TO A FLAT BLADE PLUG TERMINAL.
(THE GROUNDING WIRE HAS INSULATION
WITH AN OUTER SURFACE THAT IS GREEN
- WITH OR WITHOUT YELLOW STRIPES.)

If these grounding instructions are not completely under-
stood, or if in doubt as to whether the compressor is
properly grounded, have the installation checked by a
qualified electrician.

Location of the Air Compressor

Locate the air compressor in a clean, dry and well venti-
lated area. The air filter must be kept clear of obstructions
which could reduce air delivery of the air compressor. The
air compressor should be located at least 12" away from
the wall or other obstructions that will interfere with the
flow of air. The air compressor head and shroud are
designed to allow for proper cooling. If humidity is high, an
air filter can be installed to remove excessive moisture.
Follow the instructions packaged with the air filter for
proper installation.

Extension Cords

Use extra air hose instead of an extension cord to avoid
voltage drop and power loss to the motor.

If an extension cord 

must

 be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding
plug and a 3-slot receptacle that will accept the plug
on the product.

in good condition.

no longer than 50 feet.

12 gauge (AWG) or larger. (Wire size increases as
gauge number decreases. 10 AWG and 8 AWG may
also be used. DO NOT USE 14 or 16 AWG.)

Grounding Instructions

IMPROPER GROUNDING CAN RESULT IN
ELECTRICAL SHOCK. IN THE EVENT OF A
SHORT CIRCUIT, GROUNDING REDUCES
THE RISK OF SHOCK BY PROVIDING AN
ESCAPE WIRE FOR THE ELECTRIC CUR-
RENT. THIS AIR COMPRESSOR MUST BE
PROPERLY GROUNDED.

1. The air compressor is equipped with a cord having a

grounding wire with an appropriate grounding plug.
The plug must be used with an outlet that has been
installed and grounded in accordance with all local
codes and ordinances. The outlet must have the
same configuration as the plug. DO NOT USE AN
ADAPTER.

2. Do not modify the plug that has been provided. If it

does not fit the available outlet, the correct outlet
should be installed by a qualified electrician.

3. Inspect the plug and cord before each use. Do not

use if there are signs of damage.

INSTALLATION & BREAK-IN PROCEDURES

Содержание TURBO HOT DOG DAC-7128-2

Страница 1: ...ively for Senco Products Inc Turbo Hot Dog is a registered trademark of Senco Products Inc Cincinnati Ohio TURBO HOT DOG DAC 7128 2 PERMANENTLY LUBRICATED AIR COMPRESSOR IMPORTANT Read and follow all...

Страница 2: ...Break in Procedures 8 OPERATING PROCEDURES 9 STORAGE 9 MAINTENANCE 10 TROUBLESHOOTING GUIDE 11 AIR COMPRESSOR DIAGRAM 14 Parts List 15 COMPRESSOR PUMP DIAGRAM 16 Parts List 17 HOW TO ORDER REPAIR PAR...

Страница 3: ...LOSION OR FIRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY DRAIN TANK DAILY OR AFTE...

Страница 4: ...SSOR EITHER DI RECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL OR SAFETY DATA SH...

Страница 5: ...TECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL WHAT CAN HAPPEN HOW TO PREVENT IT A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COMPRES...

Страница 6: ...if 1 Voltage supply to circuit is normal 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications in owners manual 4 Circuit is eq...

Страница 7: ...ops the motor when the air tank pressure reaches the factory set cut out pressure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety va...

Страница 8: ...at least 12 away from the wall or other obstructions that will interfere with the flow of air The air compressor head and shroud are designedtoallowforpropercooling Ifhumidityishigh an air filter can...

Страница 9: ...d Motor will stop when tank pressure reaches cut out pressure 5 Open the regulator by turning it clockwise Adjust the regulator to the correct pressure setting Your com pressor is ready for use 6 Alwa...

Страница 10: ...using a socket wrench 6 Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper closed position The check valve may be cleaned with a solvent such...

Страница 11: ...ults in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off Remove and clean or replace check valve DO NOT OVER TIGHTEN Airleaksatpressu...

Страница 12: ...h of extension cord Check valve stuck open Loose electrical connections Paint spray on internal motor parts Possible defective motor Fuseblown circuitbreakertripped Pressure release valve on pressure...

Страница 13: ...13 ENG D22235 REPAIR PARTS...

Страница 14: ...14 ENG D22235 AIR COMPRESSOR DIAGRAM...

Страница 15: ...ear Shroud Assembly includes two 4 Locknut Washer 2 used Rear Shroud Bracket 2 used included with 2 Strain Relief 2 used Cord Assembly Motor Manifold Switch On Off Label Cord Assembly line Safety Valv...

Страница 16: ...16 ENG D22235 TORQUE 100 120 in lbs TORQUE 100 120 in lbs TORQUE 7 10 ft lbs TORQUE 42 48 in lbs 47 49 48 46 43 44 45 81 51 52 56 60 61 58 59 57 55 53 54 COMPRESSOR PUMP DIAGRAM...

Страница 17: ...x Connecting Rod Cap Compression Ring Sold In Kit Connecting Rod Assembly Torque screw 30 45 in lbs Cylinder Sleeve Position locating mark toward motor Motor Eccentric Set Screw Fan Screw 10 24 x 3 8...

Страница 18: ...arranty can be found in the General Manual or is available upon request Call our Toll Free Number 1 800 888 2468 Ext 2 to obtain the location of the nearest Authorized Service Center for ordering repa...

Страница 19: ...Products Inc Le Turbo Hot Dog est une marque d pos e de Senco Products Inc Cincinnati Ohio IMPORTANT Lisez et suivez toutes les instructions et les consignes de s curit avant d utiliser cette machine...

Страница 20: ...portants que vous devez bien saisir Cette information porte sur VOTRE S CURIT et sur LA PR VENTION DE PROBL MES D QUIPEMENT Afin de vous aider identifier cette information nous avons utilis des signes...

Страница 21: ...PRESSEUR AU COMPLET NE JAMAIS PERFORER AVEC UNE PERCEUSE SOUDER OU FAIRE UNE MODIFICATION QUELCONQUE AU R SERVOIR OU SES ACCESSOIRES LE R SERVOIR EST CON U POUR SUBIR DES PRESSIONS DE SERVICE PARTICUL...

Страница 22: ...AIL NE JAMAIS INHALER L AIR MIS PAR LE COMPRESSEUR QUE CE SOIT DIRECTEMENT OU AU MOYEN D UN DISPOSITIF RESPIRATEUR BRANCH AU COMPRESSEUR TRAVAILLER DANS UN ENDROIT O IL Y A UNE BONNE VENTILATION TRANS...

Страница 23: ...EURSMINUTESAPR SLEURFONCTIONNEMENT NEPASTENTERD ATTEINDRELESCOMPOSANTESDERRI RELESGARDES DE PROTECTION ET NE PAS EFFECTUER DE L ENTRETIEN AVANT D AVOIR LAISS REFROIDIR L APPAREIL RISQUE PR VENTION UN...

Страница 24: ...s Pression de red marrage 100 Pression d arr t 120 Pi3 min std 120 lb po2 2 4 Enregistr par U L oui Approuv par l ACNOR oui Pi3 min std Pieds cubes standard par minute une unit de mesure de d bit d ai...

Страница 25: ...et le tube de sortie quand le compresseur atteint sa pression d arr t ou est arr t Si l air ne sort pas le moteur ne pourra pas d marrer Le d tendeur de pression permet au moteur de red marrer Quand l...

Страница 26: ...all e selon les codes et ordonnances locales de fa on ce que le fil de masse soit enterr N UTILISEZ PAS UN ADAPTATEUR 2 Ne modifiez pas la fiche qui vous a t livr e Si elle n entre pas dans la prise d...

Страница 27: ...Mettez le levier OFF AUTO sur OFF 8 Tournez le r gulateur dans le sens contraire des aiguilles d une montre et r glez la pression de sortie z ro 9 Enlevez l outil ou accessoire air comprim 10 Ouvrez...

Страница 28: ...che Remontez la soupape de retenue tournez dans le sens des aiguilles d une montre 8 Replacez le tube d tendeur de pression et son raccord 9 Replacez le tube de sortie d air et resserrez les crous du...

Страница 29: ...ou sale Une soupape de retenue d fectueuse causera des fuites d air continues au niveau du d tendeur de pression quand le r servoir est sous pression et que le compresseur est arr t Enlevez et nettoye...

Страница 30: ...as d pressuris la culasse GUIDE DES PANNES Fuitedanslasoupapedes ret Soupape de s ret peut tre d fectueuse Maniez la soupape de s ret la main en tirant sur la rondelle Si la soupape fuit toujours remp...

Страница 31: ...13 FR D22235 LISTE DE PI CES...

Страница 32: ...14 FR D22235 SCH MA DU COMPRESSEUR...

Страница 33: ...po de longueur 18 SSP 7811 Manchon filet pour tube de 1 4 de po de diam ext 19 SSP 9013 Ajout de tuyau 21 CAC 1245 Tube d tendeur de pression 22 SSP 6088 Raccord barbel 23 CAC 1244 Manchon de poign e...

Страница 34: ...16 FR D22235 LA POMPE DU COMPRESSUER Serrez 100 120 po lbs Serrez 100 120 po lbs Serrez 7 10 pi lbs Serrez 42 48 po lbs 47 49 48 46 43 44 45 81 51 52 56 60 61 58 59 57 55 53 54...

Страница 35: ...35 Ensemble de bielle Serrez la vis 30 45 lbs po 56 KK 4835 Manchon de cylindre encoche de position vers le moteur 57 MO 3025 2 Moteur 58 AC 0140 Excentrique 59 SSF 615 Vis de fixation 60 AC 0108 Vent...

Страница 36: ...hat en cas de r paration durant la p riode de garantie Composez notre num ro de ligne de libre appel 1 800 888 2468 poste 2 pour obtenir l adresse du Centre de service apr s vente autoris le plus proc...

Отзывы: