background image

 Safety WarNiNgS

6

200 psig

13.7 bar

Do not connect tools to air pressure that potentially exceeds 200 psig or 13.7 bar.
Regulators shall be used to limit compressed air pressure supplied to tool. 

Regulators shall be set at an operational pressure that is lower than or equal to 

manufacturers specified maximum.
Air hose must have a minimum working pressure rating of 150 PSIG (10.3 bar) or 

150% of the maximum pressure produced in the system, whichever is higher.
The tool and air supply hose must have a hose coupling such that all pressure is 

removed from the tool when the coupling joint is disconnected.

Use extra caution when driving fasteners into existing walls or other blind areas to prevent contact with hidden objects 

or persons on other side (e.g. wires, pipes, etc.).
Never use a tool that leaks air or needs repair.
Never lift, pull or lower the tool by the hose.
Keep tool pointed away from yourself and others while connecting air to the tool.
Never use any part of the tool (cap or main body) as a hammer. The tool could activate or become unsafe.

read and understand all safety instructions.

Product Safety messages

• Read and Understand tool labels and manual. Failure to follow warnings will result in DEATH or SERIOUS INJURY.
• Operators and others in work area MUST wear safety glasses with side shields.
• Keep fingers AWAY from trigger when not driving fasteners to avoid accidental discharge.
• Know and understand what trigger system you are using. Check manual for triggering options.
• NEVER point tool at yourself or others in work area.
• NEVER use oxygen or other bottled gases. Explosion may occur.

maintenance

Always refer to both tool maintenance instructions below and the troubleshooting 

guide in this manual to assure years of reliable service.
Make sure all screws and caps are securely tightened at all times. Make daily inspec-

tions for free movement of trigger and safety element. Never use the tool if parts are 

missing or damaged.
When tool is disconnected from air, make daily inspection to assure free movement of 

safety element and trigger. Do not use tool if safety element or trigger sticks or binds.
Squirt Senco pneumatic oil (5 to 10 drops) into the air inlet twice daily (depending on 

frequency of tool use). Other oils may damage O-rings and other tool parts.
Wipe tool clean daily and inspect for wear. Use non-flammable cleaning solutions only 

if necessary. 

do Not SoaK

.

WarNiNg

Repairs other than those described here should be performed only by trained, qualified personnel. Contact 

SENCO for information at 1-800-543-4596.

Содержание SN71P1

Страница 1: ...w senco com 2021 by KYOCERA SENCO Industrial Tools Inc NFD8SN71P Issued September 24 2021 IMPORTANT Read before use Warnings for the safe use of this tool are included in this manual Los avisos para e...

Страница 2: ...this manual available for use by all people assigned to the use of this tool Employer must enforce compliance with the safety warnings and all other instructions which accompany this tool as shipped f...

Страница 3: ...d shall provide protec tion against flying particles both from front and side Hearing protection shall have Noise Reduction Rating determined in accordance with US Environmental Protection Agency Rule...

Страница 4: ...gger and do not require a work contact element These tools are used in specialty applications and are typically used in industrial applications Light duty tools may have a dual action trigger The two...

Страница 5: ...d to air supply therefore remove all fasteners from tool before connecting air Do not load fasteners with trigger or workpiece contact element depressed Keep hands and body away from the fastener disc...

Страница 6: ...e to follow warnings will result in DEATH or SERIOUS INJURY Operators and others in work area MUST wear safety glasses with side shields Keep fingers AWAY from trigger when not driving fasteners to av...

Страница 7: ...ctions are available to personnel performing maintenance shall ensure that tools that require repair are removed from service and that tags and physical segregation are used as a means of control Tool...

Страница 8: ...ce Nail Height Adjustment Nail Canister Loading Clearing Gate Removable No Mar Pad Workpiece Contact Element Inlet Air Fitting Belt Hook Adjustable Exhaust Deflector Adjustable Depth of Drive Latch Op...

Страница 9: ...ith a Contact Actuation Dual Action trigger fasteners can be driven two ways 1 2 The First Way Press the workpiece contact safety element against the work surface Pull the trigger and the fastener is...

Страница 10: ...nger rotate wheel to adjust the Depth Control The work piece contact element will move to change the desired depth of the fastener The tool can be converted for non toenail flat surface applications b...

Страница 11: ...ston seal or sleeve wear If parts are worn or damaged parts are detailed in the parts chart Clean tool Tighten screws Tool skipping Low air pressure Check air supply Consider using larger diameter air...

Страница 12: ...rnal lever Trigger will be grey Selectable Actuation TRIGGER HC0534 This Contact Actuation Choice is meant for rapid fastener placement Read the safety warning on page 4 for additional recommendations...

Страница 13: ...mm SE 1 3 4 1 1 2 1 1 4 082 092 ED 2 3mm 1 3 4 092 2 3mm 2 1 4 2 1 4 EL 2 1 3 4 2 15 Degree Wire Welded or Plastic Carrier Coil Senco Fastener Code Inches mm SE 1 1 4 32 1 1 2 38 1 3 4 45 ED 1 3 4 45...

Страница 14: ...ENCO Cordless tools will be free from defects in material and workmanship for one year after the purchase date Warranty Exclusions The following warranty exclusions apply 1 seals driver blades piston...

Страница 15: ...Notes...

Страница 16: ...KYOCERA SENCO Industrial Tools Inc 8450 Broadwell Road Cincinnati Ohio 45244 1 800 543 4596 www senco com...

Отзывы: